FTK crates, power supplies and cooling issues 13/03/20131FTK-IAPP workshop - A. Lanza  Racks, crates and PS: requirements  Wiener crates  Rittal crates.

Slides:



Advertisements
Similar presentations
Goals and status of the ATLAS VME Replacement Working Group Markus Joos, CERN Based on slides prepared by Guy Perrot, LAPP 19/09/2012.
Advertisements

SCT Power Supply Installation Schedule Jan Bohm, Prague AS, 4 th November 2005 The SCT Power Supply System will be installed in 22 LV&HV racks situated.
Enclosures & ComponentsBackplanesSystem PlatformsSwitches, Knobs & LEDsCabinets ATCA Systems Technology Meeting CERN Genève.
Power distribution box XD1 top DTTF_Crate XD2 middle DTTF_Crate XD3 bottom DTTF_Crate Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 RACK S1D01.
David Emschermann DCS Workshop – PI Heidelberg – 22/01/2007 How to power up the TRD David Emschermann Physikalisches Institut Universität Heidelberg updated.
Track quality - impact on hardware of different strategies Paola FTK meeting Performances on WH and Bs   2.Now we use all the layers.
Building a Computer Kate Chapin Capstone Project.
Assembling a Computer Safety Precautions CPU Installation
ZTF Interconnecting Scheme Stephen Kaye
A* candidate for the power supply Wiener MPOD-LV crate w/ remote control only (except for local on/off switch) Type “EC LV” Front or rear connections (reverse.
FTK poster F. Crescioli Alberto Annovi
1 Computer Power Supply Amateur Radio Conversion For Cheap +12 vdc Power March 17, 2003.
Low Voltage Power Requirement of TOF FEEs. Maximum tray. Low Noise:  Periodic and Random Distortion (PARD) < few mV RMS Floating.
4 Amp Load.500 Hard Line Cable SPSM 2 P/S Setup Configuration RF Signal Supplied by RG-6 RF Signal To TV via RG-6 Remove Central Fuse Move 20A fuse from.
Electronic Systems Support LHC Crates 2005 Paul Harwood PH Electronic Systems Support Group (PH-ESS) Meeting Sept 1, 2004.
1 5 December 2012 Laurent Roy Infrastructure / Electronics Upgrade -Cabling (long distance) -Rack and Crate (space, electrical distribution, cooling) -Detector.
Figure 1: ICD Single Channel Block Diagram Schematic PMT High Voltage Supply (see Figure 4 & 4a) LED Pulser PMT Calibration (see Figure 6) ICD Scintillator.
DCS T0 DCS Answers to DCS Commissioning and Installation related questions ALICE week T.Karavicheva and the T0 team T0 DCS Answers to.
Alex Madorsky University of Florida/Physics Track Finder production readiness review, Rice, August 2004 Track Finder Crate, Backplane and Parts Alex Madorsky.
Evaporative Heater Design, qualification and planning M.Olcese PRR SCT off-detector cooling PRR SCT off-detector cooling March March 2005.
John Coughlan Tracker Week Feb FED Status FED Production Status Transition Card.
AMB HW LOW LEVEL SIMULATION VS HW OUTPUT G. Volpi, INFN Pisa.
Pixel power R&D in Spain F. Arteche Phase II days Phase 2 pixel electronics meeting CERN - May 2015.
1 FTK AUX Design Review Functionality & Specifications M. Shochet November 11, 2014AUX design review.
SMPS.
1 13 Octobre 2011 Laurent Roy ATCA Crate / Infrastructure in place -Rack in D3: dimension -Electrical power availability -Tell1 racks running in D3 (air.
AFP Trigger DAQ and DCS Krzysztof Korcyl Institute of Nuclear Physics - Cracow on behalf of TDAQ and DCS subsystems.
K. Luchini LCLS Injector /BC1 Magnet PS Final Design Review, March 30, Injector and BC1 Magnet PS Controls K. Luchini.
ATCA COOLING PROJECT INTERSHIP FINAL PRESENTATION Piotr Koziol.
Geoff HallLECC LHC detector upgrades Introductory comments on electronic issues Organisation of this short session.
System Demonstrator: status & planning The system demonstrator starts as “vertical slice”: The vertical slice will grow to include all FTK functions, but.
Status of integration in USA15. Status of rack layout 20/03/2015FTK Italia - A. Lanza2 Rack Y A2 equipped with turbine cooling system and nominal.
FTK high level simulation & the physics case The FTK simulation problem G. Volpi Laboratori Nazionali Frascati, CERN Associate FP07 MC Fellow.
News on FTK rack infrastructure A. Lanza – INFN Pavia FTK Italy meeting –
Calliope-Louisa Sotiropoulou FTK: E RROR D ETECTION AND M ONITORING Aristotle University of Thessaloniki FTK WORKSHOP, ALEXANDROUPOLI: 10/03/2014.
Summary of IAPP scientific activities into 4 years P. Giannetti INFN of Pisa.
Status of FTK Paola Giannetti INFN Pisa for the FTK Group ATLAS Italia November 17, 2009.
AMBFTK Report AMBFTK: problems to solve Power distribution: Crates – compatibility with CDF crates? Thermal dissipation: Cooling Signals I/O:
UPDATE ON HARDWARE 1 1.VERTICAL SLICE & COOLING TESTS 1.ONLY a TEST STAND or a SMALL DEMONSTRATOR ?? 2.CRATE.
S A Griffiths CM42 June 2015 Electrical & Control.
VME64xP 6U Crates for the ANNIE Experiment Geoff Savage October /13/2015VME64X 6U Crate for ANNIE1.
ATLAS ATCA cooling evaluation project Claudio Bortolin (EP-ADO-PO) Michal Kalinowski (EP-ADO-PO) Lukasz Zwalinski (EP-DT-FS) ATLAS cooling team – 2016.
FTK infrastructures and DCS 02/12/20101FTK Initial Design Review - A. Lanza  Crates  Single rack layout  Cabling  Rack placement  DSS  DCS.
CERN Giovanna Lehmann, Xavier Pons
Outline The Pattern Matching and the Associative Memory (AM)
Mauro Citterio - Mi meeting
Firmware development for the AM Board
Chapter Objectives In this chapter, you will learn:
Lesson 10: Thevenin’s Theorem and Max Power Transfer
IAPP - FTK workshop – Pisa march, 2013
T-simulation OUTLINE Inputs to the T-simulation: chips, boards, crate mechanics and fan T-simulation performed into two steps: On large scale: simple AM.
D. Breton, S. Simion February 2012
Rack Design Proposal as of 01/03/2013
LAMB: Hardware & Firmware
FTK infrastructure in USA15 Status and plans for 2015 A
AM system Status & Racks/crates issues
* Initialization (power-up, run)
2018/6/15 The Fast Tracker Real Time Processor and Its Impact on the Muon Isolation, Tau & b-Jet Online Selections at ATLAS Francesco Crescioli1 1University.
Pending technical issues and plans to address and solve
EMU Slice Test Run Plan a working document.
HVI HIPOT TEST SET Pft sERIES.
SCT/Pixel Draft Rack Layout rcj
Report on radiation test done in Casaccia on January 11, 2006
VeLo Analog Line Status
ATLAS USA15 - Rack 52U with 9U crates, remote PS
Track Finder Crate, Backplane and Parts
KICK OFF meeting - project presentation
FIGURE 24-1 The two horns on this vehicle were finally located under the front bumper. They were not visible until the vehicle was hoisted.
Pierluigi Paolucci & Giovanni Polese
Horn, Wiper, and Blower Motor Circuits
Presentation transcript:

FTK crates, power supplies and cooling issues 13/03/20131FTK-IAPP workshop - A. Lanza  Racks, crates and PS: requirements  Wiener crates  Rittal crates  Mixed crates  Cooling tests and first results  Next steps

FTK racks 13/03/20132FTK-IAPP workshop - A. Lanza FTK tracks to FTK RODs DF #2 DF #3 FTK core #2 FTK core #1 FTK core #8 FTK core #7 FTK ROD + test brds FTK tracks to FTK ROSes Detector hits to FTK core crates DF #1 S-Links from Pixel and SCT RODs Core racks (5 to 7)

Example of a core Crate Extrapolate to SCT stereo + 11-layer fits + removal of 11- layer fit duplicates 7-layer (3 pixel + 4 axial SCT) AM + fits FTK Output tracks to FTK ROD Stereo SCT hits from DF Hits from DF Pix+axial SCT EXS + TF + HW (Final) AM 00 + TSP(DC) + DO + TF + HW AM 01 + TSP(DC) + DO + TF + HW AM 02 + TSP(DC) + DO + TF + HW AM 03 + TSP(DC) + DO + TF + HW EXS + TF + HW (Final) AM 04 + TSP(DC) + DO + TF + HW AM 05 + TSP(DC) + DO + TF + HW AM 06 + TSP(DC) + DO + TF + HW AM 07 + TSP(DC) + DO + TF + HW EXS + TF + HW (Final) AM 08 + TSP(DC) + DO + TF + HW AM 09 + TSP(DC) + DO + TF + HW AM 10 + TSP(DC) + DO + TF + HW AM 11 + TSP(DC) + DO + TF + HW EXS + TF + HW (Final) AM 12 + TSP(DC) + DO + TF + HW AM 13 + TSP(DC) + DO + TF + HW AM 14 + TSP(DC) + DO + TF + HW AM 15 + TSP(DC) + DO + TF + HW VME Controller 7layer tracks 11 layers FTK tracks 1  tower 13/03/20133FTK-IAPP workshop - A. Lanza Power limit for the single crate: 5kW

Crates Requirements:  9U with VME64X backplane with 21 slots  power supply (PS) with (5kW) -> PS must be customized  rear card cage up to 28 cm deep for the AUX boards  For good cooling of AUX boards, the PS must be placed externally to the bin  We need four 48V pins on the VME backplane, in order to deliver the full necessary current. We decided to use the V1 and V2 power pins and their returns, V1ret and V2ret. The 48V ground is connected to the common ground Commercial crates on the market:  Wiener is at present the main producer of VME64X 9U crates, available in two versions: 6021 and  In the past, Rittal USA produced VME 9U crates for CDF. Some of them are available Constraints of Wiener crates:  3U PS(UEP6021) is only 3kW, 6U needed to extend to 6kW with  6023 is 12U high, while 6021 is 11U. In order to fit the ATLAS standard 52U rack with three crates, model 6021 is preferred  Cost!! 13/03/2013FTK-IAPP workshop - A. Lanza4 Wiener VME64X-9U 6021

Wiener crates 13/03/2013FTK-IAPP workshop - A. Lanza5 One Wiener crate was installed last year at Cern. It is composed of a standard bin + fan unit, and a special PS (PL 500 customized). The total height, including the heat exchanger in between PS and bin not yet installed, is 18U. The PS was properly customized and can deliver and The big current on the 5V is due to the original CDF AMBoard requirements

Rittal crates (CDF) 13/03/2013FTK-IAPP workshop - A. Lanza6 Used in CDF and very old (and dirty). Their PS must be replaced (not compliant) and the fan unit must be modified (working at 115 VAC). The original 5V PS was rated at 315A

Mixed crates 13/03/2013FTK-IAPP workshop - A. Lanza7 We are now testing a mixed crate composed of the Wiener PS (same as installed at Cern) and of the CDF bin, heat exchanger and fan unit, properly modified to allow operation with 230 VAC. PS cabling is quite chaotic because of the huge and heavy CDF cables on the

Cooling test setup 13/03/2013FTK-IAPP workshop - A. Lanza8 The setup is based on the mixed crate described before. Three shunts were added to the PS for reading out currents. Shunt voltage drops are displayed by three voltmeters. The load is composed of nine (at the moment) load boards, detailed in the next slide. Three load boards are equipped with 4 T sensors each, supplied by and external power supply and read out by a multimeter

Load boards 13/03/2013FTK-IAPP workshop - A. Lanza9 They were produced by CDF. Current load is composed of various resistor banks supplied by the 3.3V, 5V, ±12V, V1 and V2. V1 and V2 were properly modified to allow their use with the special 48V. Resistor banks can be connected or disconnected by means of fuses placed close to the VME connectors. Three load boards were modified inserting T sensors at the four corners

Layout of load boards 13/03/2013FTK-IAPP workshop - A. Lanza10 Load boards are installed into the crate as shown in the below picture at the left, occupying positions from 1 to 10. The three of them in positions 1, 5 and 10 are equipped by T sensors, placed in the four corners of each board as shown in the right picture. The first cooling tests were performed with 4, 7 and 9 boards, placed respectively in positions 1, 5, 9 and 10 (first test); 1, 2, 4, 5, 6, 9 and 10 (second test); 1, 2, 3, 4, 5, 7, 8, 9 and 10 (third test )

First results 13/03/2013FTK-IAPP workshop - A. Lanza11 First test with only 4 loads reached 1.3kW. T on the Loads 1, 5 and 10 are plotted here -> The max T was recorded on the load 5, lower front sensor (46.2 °C), but on average T were quite low. Second test used 7 loads and reached 2.2kW. On average there is a T increase of about 6-7 °C. The third test used 9 boards and reached 2.7kW. The T increase is quite moderate, at the level of 2- 3 °C

Next steps 13/03/2013FTK-IAPP workshop - A. Lanza12 1 – Power dissipation must be increased up to 5kW. This will require to install some additional loads (available) and probably to add some resistor banks to the 48V 2 – T sensor coverage must be extended to the central regions, adding there a couple of them, and other loads need to be equipped with sensors 3 – A standard Wiener fan unit, with 6 fans, is available and it can be compared with the CDF unit. At the moment we are not able to switch on this unit, help of Wiener was required. This fan unit equipping the crate under test is visible in the picture

Next steps – cont’d 13/03/2013FTK-IAPP workshop - A. Lanza13 4 – Read/write accesses to an AMBoard can be performed using a VME CPU (VP110). Hardware is available 5 – A chiller is ready to connect to the heat exchanger, realizing a system fully compatible with the Atlas ones. This should the test with the final conditions