Presentation is loading. Please wait.

Presentation is loading. Please wait.

4 Amp Load.500 Hard Line Cable SPSM 2 P/S Setup Configuration RF Signal Supplied by RG-6 RF Signal To TV via RG-6 Remove Central Fuse Move 20A fuse from.

Similar presentations


Presentation on theme: "4 Amp Load.500 Hard Line Cable SPSM 2 P/S Setup Configuration RF Signal Supplied by RG-6 RF Signal To TV via RG-6 Remove Central Fuse Move 20A fuse from."— Presentation transcript:

1 4 Amp Load.500 Hard Line Cable SPSM 2 P/S Setup Configuration RF Signal Supplied by RG-6 RF Signal To TV via RG-6 Remove Central Fuse Move 20A fuse from spare location to fused location 1 Short Test PPT Final

2 4 Amp Load.500 Hard Line Cable SPSM 4 P/S Setup Configuration RF Signal Supplied by RG-6 RF Signal To TV via RG-6 Remove Central Fuse 2 Short Test PPT Final

3 .500 Hard Line Cable SPSM 4 P/S Setup Configuration Short Circuit RF Signal Supplied by RG-6 RF Signal To TV via RG-6 RG6 @ 150’ – 22 Volts – 15 Amp Draw On P/S 3 RG6 @ 75’ – 20 Volts – 15 Amp Draw On P/S 3 RG6 @ 36’ – 18 Volts – 15 Amp Draw On P/S 3 RG6 @ 18’ – 12 Volts – 15 Amp Draw On P/S 3 Remove Central Fuse Wrap braid around center conductor to create short. 20 Amp Fuse 20 Amp Fuse Location used to measure voltage 3 Short Test PPT Final

4 .500 Hard Line Cable SPSM 4 P/S Setup Configuration Short Circuit RF Signal Supplied by RG-6 RF Signal To TV via RG-6 With Mother Board Removed Created Short using Barrel Connector and Paper Clip, voltage was measured at this location. This yielded the 0 Volts Remove Central Fuse 4 Short Test PPT Final

5 .500 Hard Line Cable SPSM 2 P/S Setup Configuration Short Circuit RF Signal Supplied by RG-6 RF Signal To TV via RG-6 This yielded the 0 Volts Remove Central Fuse Move 20A fuse from spare location to fused location Remove Central Fuse With Mother Board Removed Created Short using Barrel Connector and Paper Clip, voltage was measured at this location. 5 Short Test PPT Final

6 .500 Hard Line Cable SPSM 2 P/S Short Circuit Applied Initial RF Signal Supplied by RG-6 RF Signal To TV via RG-6 This yielded the 0 Volts Short Applied Measured amp draw cycled between 1 to 2 Amps Measured amp draw 26 Amps Measured Voltage 87.8 Volts Switch would cycle Measured Voltage 0.0 Volts With Mother Board Removed Created Short using Barrel Connector and Paper Clip, voltage was measured at this location. 6 Short Test PPT Final

7 .500 Hard Line Cable SPSM 2 P/S Short Circuit Applied After 15 to 30 seconds RF Signal Supplied by RG-6 RF Signal To TV via RG-6 This yielded the 0 Volts measured at pin connector. Short Applied Measured amp draw 15 Amps constant Measured amp draw 15 Amps Measured Voltage 87.8 Volts Cycle of switch would stop Fuse would blow here next to applied short With Mother Board Removed Created Short using Barrel Connector and Paper Clip, voltage was measured at this location. 7 Short Test PPT Final


Download ppt "4 Amp Load.500 Hard Line Cable SPSM 2 P/S Setup Configuration RF Signal Supplied by RG-6 RF Signal To TV via RG-6 Remove Central Fuse Move 20A fuse from."

Similar presentations


Ads by Google