Presentation is loading. Please wait.

Presentation is loading. Please wait.

Power distribution box XD1 top DTTF_Crate XD2 middle DTTF_Crate XD3 bottom DTTF_Crate Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 RACK S1D01.

Similar presentations


Presentation on theme: "Power distribution box XD1 top DTTF_Crate XD2 middle DTTF_Crate XD3 bottom DTTF_Crate Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 RACK S1D01."— Presentation transcript:

1 Power distribution box XD1 top DTTF_Crate XD2 middle DTTF_Crate XD3 bottom DTTF_Crate Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 RACK S1D01 DTTF crates Wiener crates UEP 6021-LHC 6U type (0P06.770) Input: 100- 240VAC ± 10% (90...265VAC) 50-60 Hz max 16A Mains input connection with a 3-pin HIRSCHMAN connector. No main fuse inside, a circuit breaker for overcurrent protection 16A type B or C has to be installed externally. (Inside the Power distribution box). Power Pout (100VAC): 1200W Pout (>159 VAC): 1900W CE / EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950 Each VME is outfitted with a grounding stud which is wired to mains earth or zero potential. DTTF Crates

2 RACK S1D02 DTTF crates Power distribution box XD2 top DTTF_Crate XD3 middle DTTF_Crate XD4 bottom DTTF_Crate Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 Wiener crates UEP 6021-LHC 6U type (0P06.770) Input: 100- 240VAC ± 10% (90...265VAC) 50-60 Hz max 16A Mains input connection with a 3-pin HIRSCHMAN connector. No main fuse inside, a circuit breaker for overcurrent protection 16A type B or C has to be installed externally (inside the Power distribution box). Power Pout (100VAC): 1200W Pout (>159 VAC): 1900W CE / EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950 Each VME is outfitted with a grounding stud which is wired to mains earth or zero potential. DTTF Crates

3 RACK S1D03 DTTF crates Power distribution box XD1 top Test Signal Crate XD2 middle DTTF_Crate XD3 DCS patch box Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 Wiener crates UEP 6021-LHC 6U type (0P06.770) Input: 100- 240VAC ± 10% (90...265VAC) 50-60 Hz max 16A Mains input connection with a 3-pin HIRSCHMAN connector. No main fuse inside, a circuit breaker for overcurrent protection 16A type B or C has to be installed externally. (Inside the Power distribution box). Power Pout (100VAC): 1200W Pout (>159 VAC): 1900W CE / EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950 Each VME is outfitted with a grounding stud which is wired to mains earth or zero potential. DTTF Crates

4 Turbine 4U Heat exchange Blank panel 14U Heat exchange Air deflector 2U Front side Blank panel 10U DSS chassis 4U National Instruments CompactRIO PLC Requiring max 17W Phoenix Conctact Quint power supply DC 5A@24V for the PLC Siemens Sitop Power Flexi power supply DC range 3÷57V 10A S1D07 DT RACK Mains & AC/DC converter Front side Back side - 2 DSS chassis equipped with 1 PLC with its power supplies and 1 power supply for signals, diagram shown Input: 1 cable 3x1,5mm2 1,5m long coming from a multiple socket-outlet block - 1 multiple socket-outlet block (5 sockets ASE 12 10A) installed by integration group - 1 Ethernet switch HP 2724 on the back side

5 Turbine 4U Heat exchange SCM CRATE 3 6U Blank panel Fan tray Heat exchange SCM CRATE 2 6U Blank panel Fan tray Heat exchange SCM CRATE 1 6U Blank panel Fan tray Heat exchange DDU patch panel 3U DDU CRATE 11U SECO patch panel 2U Heat exchange Air deflector 2U SECO patch panel 1U Front side Turbine 4U Patch panel 3U Ethernet switch Air deflector 2U Back side S1G00 DT RACK far side Mains & AC/DC converter - 1 DDU crate (Wiener VME 6023 equipped with UEP 6021 Power supply) Input: 1 cable 3x1,5mm2 3m long with Harting connectors coming from the power distributor on the top of the rack - 3 SCM crates (Elma Cpci equipped with 2 Kniel 300W FPQ-1608/VME power supplies Input: 1 cable 3x1,5mm2 1,5m long coming from a multiple socket-outlet block - 3 Fan tray requiring max 15W Input: 1 cable 3x1,5mm2 1,5m long coming from a multiple socket-outlet block - 3 Patch panel 3U for signal cables routing equipped with 2 AC/DC converter Cabur XCSD15B 12V/0,6A Input: 1 cable 3x1,5mm2 1,5m long coming from a multiple socket-outlet block. Earth wire connected to case - 3 multiple socket-outlet block (5 sockets ASE 12 10A) installed by integration group - 1 Ethernet switch HP 2724


Download ppt "Power distribution box XD1 top DTTF_Crate XD2 middle DTTF_Crate XD3 bottom DTTF_Crate Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 RACK S1D01."

Similar presentations