Chapter 8: The Cooling Load Cooling load is the rate at which energy must be removed from a space to maintain the temperature and humidity at the design.

Slides:



Advertisements
Similar presentations
Heating and Air Conditioning I
Advertisements

HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
eQuest Quick Energy Simulation Tool
Heating, Ventilating, and Air-Conditioning
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Tas seminar/demonstration on Part L 2006 of the Building Regulations Presented by Alan Jones EDSL February
Load Calculations Dr. Sam C M Hui MECH3005 – Building Services
Content Introduction RTS Concept / Theory Demonstration.
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
BASIC PRINCIPLES IN OCCUPATIONAL HYGIENE Day THERMAL ENVIROMENT.
1 ISAT Module III: Building Energy Efficiency Topic 6:Stead-State Building Loads z Fabric Loss z Ventilation Loss z Environmental Temperature z Steady-State.
BEM class 3 Climate & Human Comfort. Class (lecture) objectives Appreciation of the indoor and outdoor environments and how they relate to our energy.
Heating energy calculation methods Anti Hamburg Lecture TTK-UAS.
HVAC 7ab CNST 305 Environmental Systems 1 Dr. Berryman
Conduction Cooling Loads
Air Conditioning. Definition: Any treatment of the environment air within a building is air conditioning. Air cooling is any process that reduces air.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
CHE/ME 109 Heat Transfer in Electronics
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
Walls. Apply knowledge of thermal mass and insulation with passive design strategies to reduce the energy needed by active systems.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Ductless Heat Pumps Sizing Example
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
ARC 810: Building Climatology Department of Architecture, Federal University of Technology, Akure, Nigeria ARC 810: Building Climatology Department of.
Distinct properties of snow
Meteorology Ch 3 Jeopardy
Passive Design in the Pacific Environment Passive Design in the Pacific Environment PASSIVE DESIGN FOR THERMAL COMFORT IN A TROPICAL ENVIRONMENT Neil Purdie.
1._____process that forms clouds (water cycle 2) 2._____ process that adds heat and changes liquid water to water vapor (water cycle) 3._____what powers.
Tutorial 4: Response function method Q1. Outline the calculation steps of a time domain response function method. 1. A given heat transfer equation in.
1)Does ECJ have a larger heating or cooling load? A.Heating B.Cooling.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1 ISAT Module III: Building Energy Efficiency Topic 7: Transient Heating and Air Conditioning Loads  Thermal Admittance  Intermittent Heating 
0 Load Calculation Manual Output : 1. Screen Outputs (Results, Pareto Chart, Hourly Estimation) 2. Optional Outputs (*CLTD.txt, *TETD.txt) 3.
CBE 150A – Transport Spring Semester 2014 Radiation.
INTRODUCTION TO HEAT LOAD HEAT LOAD12 3 TOPICS COVERED INTRODUCTION DESIGN CONSIDERATIONS DEFINITIONS/CONCE PT/FORMULA THE FORM LOAD COMPONENTS –External.
A Closer Look at Energy Demands: Quantification and Characterisation.
Introduction to Energy Management. Lesson 4 Determining the Loads on the HVAC System.
Cooling/Heating Load Computations
Efficiency of the human Body We can consider the human body as a machine in doing external work.
1._____process that forms clouds (water cycle 2) 2.____ layer of atmosphere that weather occurs in (atm layers) 3._____ process that adds heat and changes.
The Cycling of Energy Chapter 3-3 Study Guide. What is heat flow?  The transfer of energy from a warmer object to a cooler object.
Development of a new Building Energy Model in TEB Bruno Bueno Grégoire Pigeon.
EnergyPlus applied to urban climate studies
Essential Question: How and where do the 5 types of fog form?
THERMAL COMFORT.
© 2011 Autodesk Vasari Talk – How accurate is Vasari? Wednesday 11 th October 2012.
Heat transfer mechanism Dhivagar R Lecture 1 1. MECHANISMS OF HEAT TRANSFER Heat can be transferred in three different ways: conduction, convection, and.
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
Chapter 8: TRANSIENT ANALYSIS METHODS FOR BUILDING ELEMENTS
HEAT GAIN CALCULATIONS
COMFORT Absence of discomfort or dissatisfaction.
Thermal mass dynamics 1.00 Heat absorption
Conduction Cooling Loads
Chapter 2C: BASIC THERMAL SCIENCES: RADIATION HEAT TRANSFER
The Internal Environment & Human Comfort
Heat Loss and Gain Heat Loss and Gain
Lecture Objectives: Review linearization of nonlinear equation for unsteady state problems Learn about whole building modeling equations.
Heat Loss and Gain Heat Loss and Gain
Make up: Project presentation class at the end of the semester
Why we need to calculate heating load ?
Lecture Objectives: Discuss HW3
Heat Transfer.
Lecture Objectives Learn about Cooling Load Calculation
Heat Loss and Gain Heat Loss and Gain
Chapter 2C: BASIC THERMAL SCIENCES: RADIATION HEAT TRANSFER
Chapter 8: TRANSIENT HEAT FLOW THRU BUILDING ELEMENTS
Presentation transcript:

Chapter 8: The Cooling Load Cooling load is the rate at which energy must be removed from a space to maintain the temperature and humidity at the design values. Cooling load is determined by internal and external heat gains as well as structure variable heat storage, all of which are transient in nature Instantaneous heat gain is the heat received by the space being conditioned. Instantaneous cooling load is the heat gain by the air in the space

The Cooling Load This figure is for solar heat gain (TSHG: total solar heat gain) and the associated cooling load. A heavy weight (HW) construction has the benefit of reducing the peak cooling load, which reduces the size of required coolers. Cooling load attributed to lights. Actual cooling load will approach the heat gain if lights remain on for a sufficiently long time.

Heat Gains

Internal Heat gain -People Adjusted heat gain is a nominal value, based on the normal percentage of men, women, and children for the application listed.

Internal Heat Gain-Lights/Miscellaneous Equipment Miscellaneous Equipment include motors, appliances, kitchen installation, lab facilities, office equipment, etc.

External Heat Gain-Radiation Solar radiation (short wavelength radiation):

Solar-Irradiation on a Surface (Google)

Thermal Radiation (long wavelength)

Images of Radiation Heat Transfer between surfaces (Google)

Thermal Radiation (long wavelength)

Exterior Convection

Image of Convection Heat Transfer between a surface and a fluid (Google)

Overview of the Heat Balance Method

Heat Balance on the jth exterior surface at a given time

Heat Balance on jth Interior surface at a given time

Heat Balance on the Zone Air

Design Condition Indoor design conditions: For average jobs in the United States and Canada, a condition of 75 F or 24 C dry bulb temperature and relative humidity of 50% is typical when activity and dress of the occupants are light. Outdoor design temperatures would depend on the selection of the high end temperatures that equal or exceed a percentage of the hours that occurred during a year. A smaller percentage may result in a greater excess cooling capacity to be installed. (Table B-1 (1a: English/1b: SI): MWS = mean coincident wind speed, MWD = mean coincident wind direction, MWB = mean coincident wet bulb temperature, MDB = mean coincident dry bulb temperature, HR: humidity ratio, in grains of water per pound of air (7000 grains equal 1 pound), Range = daily range of db temperature (the difference between the average maximum and average minimum for the warmest month).

HvacLoadExplorer Software Based on the heat balance method (HBM). It allows a user to run a cooling or heating load calculation for an entire building to determine the cooling or heating loads and airflow rate of all the rooms in a building or zone. It allows a user to calculate the conduction transfer function coefficients, response factors, radiant time series factors. For purposes of load calculations, a building may be thought of as being organized in a hierarchical fashion. That is, a building is made up of zones, zones are made up of rooms, and rooms are made up of walls, roofs, floors, and other heat gain elements such as people, lighting, equipment, and infiltration. Zones are collections of one or more rooms, all controlled to the same air temperature to allow the user to compute total loads for collections of rooms. A user may wish to include all rooms served by a particular cooling coil in a single zone so that the peak load on the coil can be readily determined. Double-clicking on a zone will show all of the rooms in the zone; double-clicking on a room will show all of the heat gain elements in the room.

Quick Start Guide First, to start describing a new building, go to the File menu and select “New”. This will ask you to specify a file name. After this step, zones may be added to the building, rooms may be added to the zone, and heat gain elements may be added to the room, with the “Add Node” button shown in Figure 1.1. Jumping ahead (assuming many of the additional steps are intuitive) users need to be aware that when they specify a wall, roof, or floor, it is important to specify an external boundary condition, as shown in Fig “TOS” should be used for exterior surfaces; “TA” for interior surfaces SW absorptivity = short wave absorptivity, related to solar irradiation LW emissivity = long wave emissivity, related to thermal radiation

Main view

Tree view First, to start describing a new building, go to the File menu and select “New”. This will ask you to specify a file name. After this step, zones may be added to the building, rooms may be added to the zone, and heat gain elements may be added to the room, with the “Add Node” button shown in Figure 1.1. Jumping ahead (assuming many of the additional steps are intuitive) users need to be aware that when they specify a wall, roof, or floor, it is important to specify an external boundary condition, as shown in Fig “TOS” should be used for exterior surfaces; “TA” for interior surfaces SW absorptivity = short wave absorptivity, related to solar irradiation LW emissivity = long wave emissivity, related to thermal radiation

List view

Setting boundary conditions for wall

Setting structures of the wall