CFD characterization and thrombogenicity analysis of a prototypal polymeric aortic valve Filippo Piatti 1, Matteo Selmi 1, Alessandra Pelosi 1, Thomas.

Slides:



Advertisements
Similar presentations
Outline Overview of Pipe Flow CFD Process ANSYS Workbench
Advertisements

Usefulness of velocity profiles based on 3D cine PC MR used as boundary conditions for computational fluid dynamics of an intracranial aneurysm : investigation.
Master’s Dissertation Defense Carlos M. Teixeira Supervisors: Prof. José Carlos Lopes Eng. Matthieu Rolland Direct Numerical Simulation of Fixed-Bed Reactors:
University of Western Ontario
Modelling FSI problems in ANSYS Fluent via UDF
Introduction: Gravitational forces resulting from microgravity, take off and landing of spacecraft are experienced by individual cells in the living organism.
Computer Aided Thermal Fluid Analysis Lecture 10
LVAD is a battery-operated, mechanical pump-type device that's surgically implanted. Goal of LVAD: providing the patient with as close to a normal lifestyle.
Reliability Prediction of a Return Thermal Expansion Joint O. Habahbeh*, D. Aidun**, P. Marzocca** * Mechatronics Engineering Dept., University of Jordan,
The activation of platelet by the combined effects of erythrocyte fragments and shear stress is not simply additive. Although, these two factors together.
Experimental and Numerical Study of the Effect of Geometric Parameters on Liquid Single-Phase Pressure Drop in Micro- Scale Pin-Fin Arrays Valerie Pezzullo,
Single and multi-phase flows through rock fractures occur in various situations, such as transport of dissolved contaminants through geological strata,
EXTREME THEORETICAL PRESSURE OSCILLATIONS IN CORONARY BYPASS Ana Pejović-Milić, Ryerson University, CA Stanislav Pejović, University of Toronto, CA Bryan.
1 Simulation of Compressible Flow around the Bullet Trains Project Members: Tatiya SameeyaiB Cheerawan Thetchanda B Project Advisor: Assist.Prof.Dr.Keerati.
CFD Pre-Lab 2 Simulation of Turbulent Flow around an Airfoil Seong Mo Yeon, and Timur Dogan 11/12/2013.
Numerical investigation on the upstream flow condition of the air flow meter in the air intake assembly of a passenger car Zoltán Kórik Supervisor: Dr.
FLOW VISUALIZATION STUDY OF WORLDHEART LEVACOR TM VAD UNDER SYNCHRONOUS PULSATILE CONDITIONS Fangjun Shu, ♥  Stijn Vandenberghe, ♥ Philip J Miller  and.
APPLIED MECHANICS Lecture 13 Slovak University of Technology
Title: SHAPE OPTIMIZATION OF AXISYMMETRIC CAVITATOR IN PARTIALY CAVITATING FLOW Department of Mechanical Engineering Ferdowsi University of Mashhad Presented.
© Copyright ASD GmbH 2006 ASD ASD Advanced Simulation & Design GmbH Virtual product development in medical technology and engineering
Multidisciplinary Histological and Mechanical Study of Aortic Aneurysm to Investigate Potential Parameters for Early Diagnosis of High Risk Rupture Pasquale.
Project #5: Simulation of Fluid Flow in the Screen-Bounded Channel in a Fiber Separator Lana Sneath and Sandra Hernandez 3 rd year - Biomedical Engineering.
Flowing Matter – COST Action MP1305, , Sofia NUMERICAL ANALYSIS OF THE STENOSIS EFFECTS ON THE BLOOD FLOW IN THE COMMON CAROTID ARTERY BIFURCATION.
1 Blend Times in Stirred Tanks Reacting Flows - Lecture 9 Instructor: André Bakker © André Bakker (2006)
Goal: Numerically study the fluid flow in a deep open channel Objectives : a)Determine boundary conditions and geometry Porous plate verification case.
VIRTUAL SIMULATION OF TRANSCATHETER AORTIC VALVE IMPLANTATION Jenna Smetana and Jessica Sider, Swanson School of Engineering THE TAVI PROCEDURE IS FEASIBLE.
CFD Study of the Development of Vortices on a Ring Wing
CFD Lab 1 Simulation of Turbulent Pipe Flow Seong Mo Yeon, Timur Dogan, and Michael Conger 10/07/2015.
Turbulence Models Validation in a Ventilated Room by a Wall Jet Guangyu Cao Laboratory of Heating, Ventilating and Air-Conditioning,
Patient-specific Cardiovascular Modeling System using Immersed Boundary Technique Wee-Beng Tay a, Yu-Heng Tseng a, Liang-Yu Lin b, Wen-Yih Tseng c a High.
Date of download: 6/21/2016 Copyright © ASME. All rights reserved. From: In Vitro Quantification of Time Dependent Thrombus Size Using Magnetic Resonance.
CFD Simulation Investigation of Natural Gas Components through a Drilling Pipe RASEL A SULTAN HOUSSEMEDDINE LEULMI.
Date of download: 7/7/2016 Copyright © ASME. All rights reserved. From: Effects of Cyclic Motion on Coronary Blood Flow J Biomech Eng. 2013;135(12):
Date of download: 7/8/2016 Copyright © ASME. All rights reserved. From: Effect of Inlet Velocity Profiles on Patient-Specific Computational Fluid Dynamics.
Date of download: 9/25/2017 Copyright © ASME. All rights reserved.
Presenter: Nicholus Tayari Akankwasa
Multi-objective optimization of nitinol stent design
ME 7980 Cardiovascular Biofluid Mechanics
BCP Analysis Update Thomas Jones 22/7/16.
Aortic Root Biomechanics After Sleeve and David Sparing Techniques: A Finite Element Analysis  Giordano Tasca, MD, Matteo Selmi, MS, Emiliano Votta, PhD,
Titolo presentazione sottotitolo
Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage  W.L Lim, Y.T Chew, T.C Chew,
Blood Stasis on Transcatheter Valve Leaflets and Implications for Valve-in-Valve Leaflet Thrombosis  Koohyar Vahidkhah, PhD, Shahnaz Javani, MS, Mostafa.
Hemodynamics of Patient-Specific Aortic Root Geometries
Date of download: 10/21/2017 Copyright © ASME. All rights reserved.
Prepared BY: Helwan University Faculty Of Engineering
Date of download: 10/31/2017 Copyright © ASME. All rights reserved.
analyzing the effect of stent geometry
Date of download: 12/26/2017 Copyright © ASME. All rights reserved.
Modeling and experimental study of coupled porous/channel flow
Nat. Rev. Cardiol. doi: /nrcardio
Neointimal hyperplasia associated with synthetic hemodialysis grafts
Viscous Flow in Pipes.
CHAPTER 6 Viscous Flow in Pipes
An example adjunctive CT imaging in the management of aortic valve replacement dysfunction. An example adjunctive CT imaging in the management of aortic.
Ao, aorta; AR, aortic regurgitation; CFD, color-flow Doppler; LV, left ventricle; LV EDP, left ventricular end-diastolic pressure; PW, pulse-wave; SBP,
Aortic Root Biomechanics After Sleeve and David Sparing Techniques: A Finite Element Analysis  Giordano Tasca, MD, Matteo Selmi, MS, Emiliano Votta, PhD,
Nat. Rev. Cardiol. doi: /nrcardio
Figure 3 A patient with aortic and mitral stenosis
Three-dimensional flow characteristics in ventricular assist devices: Impact of valve design and operating conditions  Christoph Benk, MSc, Ramona Lorenz,
CONSTANTA MARITIME UNIVERSITY FACULTY OF MARINE ENGINEERING Engineering programmed: Marine Engineering (Bachelor’s Degree) THE STUDY OF BALLAST SYSTEM.
Nat. Rev. Cardiol. doi: /nrcardio
Computational fluid dynamics in patients with continuous-flow left ventricular assist device support show hemodynamic alterations in the ascending aorta 
Blood Stasis on Transcatheter Valve Leaflets and Implications for Valve-in-Valve Leaflet Thrombosis  Koohyar Vahidkhah, PhD, Shahnaz Javani, MS, Mostafa.
Integrated morphologic and functional assessment of the aortic root after different tissue valve root replacement procedures  Ryo Torii, PhD, Ismail El-Hamamsy,
Volume 74, Issue 11, Pages (December 2008)
Individual Patient-specific Planning of Minimally Invasive Transcatheter Intervention for Heart Valve Disease  A. De Vecchi, S. Niederer, R. Rajani, S.
Multimodality imaging of aortic stenosis.
Fig. 5 Plantar skin morphology protects it from stress-induced injury.
Presentation transcript:

CFD characterization and thrombogenicity analysis of a prototypal polymeric aortic valve Filippo Piatti 1, Matteo Selmi 1, Alessandra Pelosi 1, Thomas E. Claiborne 2, Danny Bluestein 2, Alberto Redaelli 1 1 Dept. of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy 2 Dept. of Biomedical Engineering, Stony Brook University, New York, USA Polymeric prosthetic valves seem to gain advantages over both tissue and mechanical valves, as they combine excellent fluid dynamic features with long lasting performance [1]. Moreover, they can be grafted via minimally invasive transcatheter aortic valve implantation (TAVI), reducing related surgical risks and complications. Besides, heart valve optimization requires specific analysis regarding the effects of blood contact. In particular, shear-induced platelet activation can be investigated in order to estimate thrombongenicity [2, 3]. This work presents a CFD approach for characterizing the fluidynamics of a novel hemodynamically and functionally optimized polymeric prosthesis for aortic valve replacement and to evaluate its thrombogenic potential. Materials and Methods References 1.T. E. Claiborne et al. (2012) Expert Review of Medical Devices 2.D. Bluestein et al. (2010) Annals of Biomedical Engineering 3.A. Pelosi et al. (2012) Biomechanics and Modeling in Mechanobiology CAE Conference 2013 Results and Discussion Introduction Geometry Starting from the closed valve CAD model (Fig. 1a), a FEM simulation was performed, on SIMULIA© Abaqus 6.10, with a symmetrical boundary condition and an homogeneous loading reproducing systolic transvalvular pressure. The systolic valve configuration was therefore obtained (Fig. 1b). The fluid domain (Fig. 2) was reconstructed on ANSYS© 13.0 Workbench Platform, in order to reproduce the Valsalva Sinuses and the aortic arch with its three upper branches. Figure 2 – CAD 3D geometry of the flow domain within the aortic arch. The red zone represents the Valsalva Sinuses where the prosthetic valve is placed. CFD computational setup Transient CFD simulations were run on ANSYS Fluent v13.0. A systolic ejection waveform was applied to the inlet section and outflow boundary conditions (constant flow rates) were imposed to the four outlets. A k-ω turbolence model with low Reynolds corrections was adopted and blood was characterized with density equal to 1060 kg*m -3 and viscosity equal to 3 cP. The maximum velocity value, located downstream of the valve housing, was equal to 1.58 m/s, while blood stagnation phenomena were detected within the Valsalva Sinuses. The peak transvalvular pressure drop was equal to 2.41 mmHg. Velocity magnitude contours are shown in Fig. 3, at the ejection peak (T = 150 ms). Figure 3 – Contours of Velocity Magnitude [m/s] in the aortic arch and in four different locations within the Valsalva Sinuses. The valve prototype did not induce significant alterations into the aortic fluid dynamic thanks to its morphological similarity with the anatomy of the aortic valve. Pressure drop and maximum velocities were comparable with those reported for other bioprosthetic valves [1]. Particles loading history was computed over 300 ms (time step 0.1 ms) and, via a statistical analysis, the Stress Accumulation (SA) distribution was extrapolated. Figure 4 – (a) Particle trajectories coloured by Scalar Stress [Pa]; (b) Frequency distribution of the Stress Accumulation [Pa·s] in the model. Particle trajectories (Fig. 4a) were analyzed in order to quantify the level of platelet activation due to shear stress. Scalar stress and particle residence time were combined to calculate SA. The statistical distribution of SA (Fig. 4b) allowed to identify particle trajectories with a high thrombogenic risk. Conclusions The present study combined FEM and CFD simulations to evaluate the hemodynamic and thrombogenic performances of a novel hemodynamically and functionally optimized polymeric trileaflet valve. The recent growth of cardiovascular diseases, primarily due to heart valve failures such as stenosis and regurgitation, led to an increasing need of valve replacement procedures. Figure 1 – CAD images of the closed (top) and open (bottom) configurations of the optimized polymeric valve. Particle tracking Neutrally buoyant spherical particles (Ф = 3 μm), representing platelets, were injected into the fluid domain from the inlet surface through a two- phase, Discrete Phase Modeling approach. a)b) a) b) Acknowledgements The research leading to these results has received fundings from the Cariplo Foundation Project, Grant Agreement N°