GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.

Slides:



Advertisements
Similar presentations
1 Series V4T 1/4 DIN Temperature Controllers. 2 3 Watlows Next Generation Styling Series 97 Matching 1/16 DIN Limit Controller Series F4S and F4D Ramping.
Advertisements

Prescient II Extinguishing Control Panels
Variable Frequency Drives Bypass Options
سیستم آلارم دیجیتالی مجهز به ثبات خطا
… for Combustible Gas Detection S4000C Intelligent Sensors..
RJ Mann Catalytic Monitoring Systems. RJMCMS 100 Low Cost Single Engine Monitoring System Monitors Pre and Post Catalyst Temperatures, Differential Pressure.
Enhanced Easy-Stop TM Trailer ABS Training. Enhanced Easy-Stop Trailer ABS System configurations to meet any air-braked trailer application 2S / 1M, 2S.
ModCon® 75 Controller.
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
E VERY L IFE H AS A P URPOSE… Ultima ® X3 Gas Monitor.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Personal Surveyor 200 (PS200) Series
Company Confidential © 2005 All Rights Reserved. What is it? State-of-the-art: microprocessor-based, wall-mount gas monitor Easy installation and operation:
Asahi/America New Positioners: Pneumatic Actuators-Westlock P-10,K-10 Electric Actuators-Peaktronics-DHC- 100 Competitor Comparison Positioners.
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
Introducing… HVS4000 & HVS400 Toxic Gas Detectors from Halogen Valve Systems.
Remote Monitoring and Management Solutions ®
E VERY L IFE H AS A P URPOSE… Z Gard ® Family of Gas Detection Products.
UR24 Process Refractometer
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
You Can Measure the Benefits… Training Course Introduction to SmartScan.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
PYROCON12 De-Ice controller User Operation Presentation 2013.
Gas Sensor and Transmitter
The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels.
Ultima® X Series Gas Monitors
Pump Application Interface. 30 October 2006 Overview Increases the functionality of the soft starter for pumping applications - four additional trip inputs.
ONYX Product Overview.
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Process Analytics PSPI Flash Point Monitor Model
IT Series Gas Sensor Modules IT I nformation T echnology.
SCADA and Telemetry Presented By:.
1 © Red Lion Controls Inc. Introducing the RAM 9000.
Gas Alarm System 4th Floor, Kjemi V If Gas Alarm, What to do? 1.There is 1 min delay before signal goes to the fire brigades (if high alarm) 2.Hurry to.
GasGard® XL Monitor.
TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25.
MICE Decay Solenoid Quench Detector Trevor Hartnett Daresbury Laboratory.
BioWin ®. Bio Gas – The alternative energy source of the future! BioWin ® - Bio Gas Analysis of the future!
SAFE AREA USE RANGE TRANSMITTERS 300. SAFE AREA USE RANGE: TRANSMITTERS 300 zCTX/OX 300 zCSC 300 zCTX 300 « parking »
ARISSat-1 Critical Design Review Orlando, Feb 15, 2010 Inter-Connect Board (ICB) Jerry Zdenek
High Sensitivity Smoke Detection
Experts in Chem-Feed and Water Treatment An Overview of Possibilities Dulcometer Disinfection Controller ( DDC )
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
XS26-2 Expandable Safety Controller.
TRANSMITTERS OLCT80. OLCT 80 d or id (with intrinsic safety sensor block) n II2GD n For combustible and toxic gases and oxygen n Fitted with pre-calibrated.
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
E VERY L IFE H AS A P URPOSE… Toxgard ® II Gas Monitor.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
AQ 100 Series Arc Flash Protection System. Characteristics of arc protection Speed, no intentional delays Sensitive, current set-points just above loads.
Hardware Training Product: ITMS2.
Ultima ® X Gas Monitor with HART Display Version.
Electro Eye-Hye System II
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Ultrasonic Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Differential Pressure ATEX Enclosures The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
LEVEL PRODUCTS TRANSMITTERS | SWITCHES | MONITORS |SYSTEMS.
Gas Mass Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
1 Chang Shuan Electronics Co., Ltd
New product introduction:
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
WELCOME TO ASHRAE 2011 LAS VEGAS DEALER BREAKFAST MEETING
Gas Detection in Water Treatment
LDA Large Display for Analog Inputs
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Day 2 Training - Technical
GSI Asia I-Plus 3 End Control Pan
Presentation transcript:

GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio Price Performance MGS-150 IP41 MGS-150 IP66 MGS-250 IR MGS-550 GP MGS-550 XP IAM-100 HGM-MZ MGD-100

GmbH  One user interface for all sensing technologies from Bacharach – Electrochemical – Catalytic Bead – Infrared – Semiconductor  One concept for all applications – two housing styles: ABS IP 66 and aluminum explosion proof  Simplicity without sacrificing functionality MGS-550 A new Family of Transmitters

GmbH  One user interface for all family members – 5 digit, 7-segment LED, 3 Status LEDs – Magnetic wand and push buttons – Simple, single level menu structure – Analog and digital signal output – Three on-board relays (user to designate, e.g. A1, A2, Fault)  Electrical ratings – 19.5 to 28.5 VDC or 24 VAC ± 20% – 4 to 20 mA, 0 to 5 V, 1 to 5 V, 0 to 10 V, 2 to 10 V – user selectable – Modbus RTU via RS 485 – Relays 1 24 VDC/VAC, VAC MGS-550 A new Family of Transmitters

GmbH MGS-550 Electrical safety and EMC approvals

GmbH MGS-550 ATEX, IECEx Approvals, XP-version MGS-550 XP electronics enclosure  II 2G Ex d IIC Gb  MGS-550 XP sensor enclosure  II 2G Ex d IIC T4 Gb, -20 ≤ Tamb ≤ +60 ºC – Each enclosure has its own approval. – However, the combination has not been submitted.

GmbH Four types of instruments  One local sensor: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 2 wires for analog output (4 if redundant) – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 General Purpose Un-used ports can be plugged. Plugs and cable glands are supplied.

GmbH Four types of instruments  One remote sensor: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 2 wires for analog output (4 if redundant) – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 General Purpose Un-used ports can be plugged. Plugs and cable glands are supplied. Order remote sensor separately.

GmbH Four types of instruments  Two local sensors: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 4 wires for analog output – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 General Purpose Un-used ports can be plugged. Plugs and cable glands are supplied. Order second sensor separately.

GmbH Four types of instruments  One local and one remote sensor: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 4 wires for analog output – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 General Purpose Un-used ports can be plugged. Plugs and cable glands are supplied. Order remote sensor separately.

GmbH Four types of instruments  Two remote sensors: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 4 wires for analog output – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 General Purpose Un-used ports can be plugged. Plugs and cable glands are supplied. Order remote sensors separately.

GmbH Four types of instruments  One local sensor: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 2 wires for analog output (4 if redundant) – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 Explosion Proof No cable glands are supplied with the instrument ! Two plugs are supplied.

GmbH Four types of instruments  One remote sensor: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 2 wires for analog output (4 if redundant) – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 Explosion Proof No cable glands are supplied with the instrument ! Two plugs are supplied. Order remote sensor separately.

GmbH Four types of instruments  Two local sensors: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 4 wires for analog output – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 Explosion Proof ? No cable glands or elbow are supplied with the instrument ! Two plugs are supplied. Order second sensor separately. R&D is still working on this solution. Elbow not supplied.

GmbH Four types of instruments  One local and one remote sensor: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 4 wires for analog output – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 Explosion Proof No cable glands are supplied with the instrument ! Two plugs are supplied. Order remote sensor separately.

GmbH Four types of instruments  Two remote sensors: – 5 digit, 7 segment LED display – 3 status LEDs – 4 magnetic switches and push buttons – 2 wires for power – 4 wires for analog output – 2 wires for digital output – 3 SPDT relays; independent to designate MGS-550 Explosion Proof No cable glands are supplied with the instrument ! Two plugs are supplied. Order remote sensors separately.

GmbH O2 30 Vol% CO1,000 ppm H2S 100 ppm NH3 100 / 1,000 / 5,000 / 10,000 ppm / 100 %LEL CO2 5,000 / 10,000 / 20,000 / 30,000 / 40,000 / 50,000 ppm Refrigerants 1,000 / 10,000 ppm Combustible Gases5,000 ppm / 100 %LEL H2 5,000 / 10,000 ppm C2H42,000 ppm VOC 1,000 ppm Cl2 10 ppm F2 1 ppm HCl 10 ppm SO2 10 ppm NO2 20 ppm HCN 30 ppm O3 1 ppm MGS-550 Detectable Gases and Ranges

GmbH MGS-550 User Interface 5-digit, 7-segment red LED display Three status LEDs Four magnetic switches (both versions) Four push buttons on round Bezel

GmbH MGS-550 Interface PCB Access to sensor connectors; power, communication and relay terminals. Use 16 to 20 AWG / 0.5 to 1.5 mm2 wires.

GmbH MGS-550 Gas Alarm Generation – Non-Latching Alarm 1 State A1 Hysteresis = 5% of full scale Gas Level Alarm-On Level Alarm-Off Level Fixed hysteresis to avoid chatter around the alarm set- point

GmbH MGS-550 Gas Alarm Generation – Non-Latching for Oxygen Fixed hysteresis to avoid chatter around the alarm set- point

GmbH MGS-550 Gas Alarm with ON Delay set Alarm 1 On A1 ON Delay ON Delay time selectable 0 to 15 minutes

GmbH MGS-550 Gas Alarm with ON Delay set If set, alarm condition must exist for at least the ON Delay time before an alarm is generated Alarm 1 On A1 ON Delay Delay Reset

GmbH MGS-550 Multiple Gas Alarms with ON Delay set If set, alarm condition must exist for at least the ON Delay time before an alarm is generated Alarm 1 On A1 ON Delay 1 A2 A3 ON Delay 2 Alarm 2 On ON Delay 3 Alarm 3 On

GmbH MGS-550 Gas Alarm with OFF Delay set – Non-Latching OFF Delay time selectable 0 to 15 minutes Alarm 1 On A1 OFF Delay

GmbH MGS-550 Gas Alarm with OFF Delay set – Non-Latching If set, alarm condition must expire for at least the OFF Delay time before an alarm is reset Alarm 1 On A1 OFF Delay

GmbH MGS-550 Gas Alarm with ON and OFF Delay set – Non-Latching If set, alarm condition must exist for at least the ON Delay time before an alarm is generated and expire for at least the OFF Delay time before an alarm is reset Alarm 1 On A1 ON Delay OFF Delay

GmbH MGS-550 Latching Gas Alarm A latching gas alarm stays on until it is acknowledged Alarm 1 On Acknowledgement A1

GmbH MGS-550 Multiple Latching Gas Alarms Latching gas alarms stay on until they are acknowledged Alarm 1 On Acknowledgement A1 A2 Alarm 2 On

GmbH MGS-550 Acknowledgeable Gas Alarm and Timeout An acknowledged gas alarm will be triggered again if the alarm condition still exists after the timeout has expired. Timeout selectable between 0 and 59 minutes. Alarm 1 On Acknowledged A1 Alarm 1 On Timeout

GmbH MGS-550 Acknowledgeable Multiple Gas Alarms and Timeout Acknowledged gas alarms will be triggered again if the alarm conditions still exist after the timeout has expired Alarm 1 On A1 Alarm 1 On A2 Alarm 2 On Acknowledged Alarm 2 On Timeout

GmbH MGS-550 Acknowledgeable Multiple Gas Alarms and Timeout An acknowledged gas alarm will be triggered again if the alarm conditions still exist after the timeout has expired, whereas A2 will not be triggered again in this scenario. Alarm 1 On A1 Alarm 1 On A2 Alarm 2 On Acknowledged Timeout

GmbH MGS-550 Acknowledgeable Gas Alarm and Timeout An acknowledged gas alarm will be triggered again if the alarm condition still exists after the timeout has expired. Any other gas alarm will be triggered immediately once the condition exists. Alarm 1 On A1 Alarm 1 On A2 Alarm 2 On Acknowledged Timeout

GmbH MGS-550 Acknowledgeable Multiple Gas Alarms and Timeout Reset An acknowledgement will reset a timeout. However, the gas alarm will be triggered again if the alarm conditions still exist after the new timeout has expired. Alarm 1 On A1 A2 Alarm 2 On Acknowledged Alarm 1 On Alarm 2 On Timeout Timeout Reset

GmbH MGS-550 Acknowledgeable Gas Alarm and ON Delay An acknowledgement during the ON Delay time has no effect. The gas alarm will be triggered if the alarm condition still exists. Alarm 1 On A1 ON Delay Acknowledged

GmbH MGS-550 Acknowledgeable Gas Alarm and OFF Delay An acknowledgement during the OFF Delay time will immediately reset the gas alarm. Alarm 1 On A1 Acknowledged

GmbH MGS-550 Acknowledgeable A1 and Latching A2 An acknowledgement will reset the gas alarms and clear the latching configuration of alarm 2. Alarm 1 On A1 A2 Alarm 2 On Alarm 1 Acknowledged and Alarm 2 Latching Cleared