1 TRANSPORTABLE STAND ALONE MULTIGAS DETECTOR BM 25

2 BM25 STAND ALONE DETECTOR: BM25 Rugged Has been specially designed for operation in harsh and corrosive environments High visibility and audible alarm Fitted with a large flashing red LED module and 2 « loud hooters » : 103db/1m.

3 Safety in the field Designed for team protection: rescue teams… Area surveillance for mobile or short term works Used where fixed detection systems are inapropriate or not present

4 BM25 BM25 = rugged MX 2100 version Keep the MX2100 characteristics and other new functions : a new king of cells «serie 7/3 » programmable relay outputs «gas and fault alarms » 2 programmable 1/0 inputs charger input Trickle charge in EX areas Safety perimeter RS485 or radio communication outputs ; (new developments).

5 BM 25 BM 25 : description Red flashing beacon (protected) Loud hooters protected buttons 2 connectors (outputs) on each side of casing LCD display Carrying handle sensors Sizes:467x195x180mm (H P L) Weight : 6.8 kgs IP 66

6 BM 25 BM 25 : description

7 BM 25 BM 25 :external connectors right side Left side Relay outputs (default and gas) and 2 logic inputs (remote acknowledment and remote alarm) I/O RS485 (new development) Charger (230ACV or 12 to 30 DCV) Trickle charge input

8 Example of remote alarm 0 % CH4 GAS ALARME1 20.9 % O2 15 : 05 : 29 0 ppm CO 0 ppm H2S 20.9 % O2 AL. TRANSFERT 0 ppm CO 0ppm H2S Message of remote alarm

9 GAS AL STRAIGHT FORWARD Max. BM25 connected : Unlimited Cable : 01 IP 09 EG SF Cable : 02 IP 05 EI SF Input 1 : activated Output 1 : activated on all alarms Alarm transfert : activated AL. TRANSF Junction box

10 STRAIGHT FORWARD Max. BM25 connected : Unlimited Cable : 01 IP 09 EG SF Cable : 02 IP 05 EI SF Input 1 : activated Output 1 : activated on all alarms Alarm transfert : activated GAS AL AL. TRANSF x

11 LOOP / SAFETY PERIMETER AL. TRANSF Max. BM25 connected : Unlimited Cable : 01 IP 09 EG SF Cable : 02 IP 05 EI SF Input 1 : activated Output 1 : activated on all alarms Alarm transfert : activated GAS AL AL. TRANSF

12 LOOP / SAFETY PERIMETER AL. TRANSF Max. BM25 connected : Unlimited Cable : 01 IP 09 EG SF Cable : 02 IP 05 EI SF Input 1 : activated Output 1 : activated on all alarms Alarrm transfert : activated GAS AL AL. TRANSF ACKNOLEDGEMENT

13 LOOP / SAFETY PERIMETER Max. BM25 connected : Unlimited Cable : 01 IP 09 EG SF Cable : 02 IP 05 EI SF Input 1 : activated Output 1 : activated on all alarms Alarrm transfert : activated AL. TRANSF

14 LOOP / SAFETY PERIMETER Max. BM25 connected : Unlimited Cable : 01 IP 09 EG SF Cable : 02 IP 05 EI SF Input 1 : activated Output 1 : activated on all alarms Alarrm transfert : activated AL. TRANSF To acknowledge : 1/ open the loop 2/ acknowledge each BM25 ACKNOWL.

15 GAS AL STAR INTERCONNECTION Max. BM25 connected : Unlimited Cable : 01 IP 09 EG SF Cable : 02 IP 05 EI SF Input 1 : activated Output 1 : activated on all alarms Alarrm transfert : activated GAS AL AL. TRANSFERT

16 TREE INTERCONNECTION Max. BM25 connected : 3 + 1 Cable : 01 IP 09 EG SF Cable : 02 IP 05 EI SF Input 1 : activated Output 1 : activated on all alarms Alarrm transfert : activated GAS AL AL. TRANSFERT

17 Example of remote alarm Example of remote alarm ( logic inputs) 0 % CH420.9 % O2 AL. TRANSFERT 0 ppm CO0 ppm H2S « manual call point » FUNCTION

18 BM 25 BM 25 : batteries Pack of NiMH batteries (7V2/9AH), rechargeable without opening Autonomy = according to the configuration : Up to 170h operations non-stop Or for example 90 hours with explo/O2 and 2 toxic cells. Recharged in less than :4h30mn.

19 BM 25 BM 25 : remote power supply It’s possible to trickle the BM25 in a classified zone linked with «a remote intrinsic safety power » (with flammable and toxic cells only) For these reason,in this case and without alarm, the BM25 will work practically indefinitely !! But with alarm triggering,batteries will be discharged a bit.

20 Remote power supply in a classified zone Intrinsically safe remote power supply ZONE 0 Zone 0 Safety zone BM 25

21 BM25 BM25 : smart blocks 1 and 2= mini toxic or O2 smart block of cell 3= médium toxic or O2 4= EXPLO smart block of cell 5= médium or series 3/7 (new developments). 41 2 3 5 Note: without a block somewhere, take in place a dummy cell to keep the index of protection (IP66).

22 BM25 BM25 : smart blocks All the cells are: « plug in » easy connexion smart because fitted with a memory of characteristics (type of detected gas, unit, scale, sérial number, usure rate etc… Pre-calibrated Interchangeable.

23 BM25 BM25 : smart blocks Channel 5 can be fitted with either a medium cell or a big model (series 3) Note: BM 25 is fitted with 5 channels but can make a gestion of 4 only! For this reason if you use the channel N° 5, the 1 st will be automatically inhibited and the cell deactived ! 4 1 2 3 5

24 BM25 BM25 : explosible smart-blocks This channel is obligatory connected with a flammable cell for detection of major explo.gas and 2 types of cell can be used : catalytic or catalytic/catharometric.

25 BM25 BM25 : explosible smart-blocks « universal »: catalytic c ell Scale of measurement = 0 to 100% LEL « Non ambiguity measurement message » if the signal is tooà high > 100% LEL Choice of detected explo. gas (preprogrammed list) choice of a special type « all the gas »: the new cell, recently developped by Oldham, will indicate a correct concentration of the explo. gas detected whatever the type and in spite of a unic calibration with CH4 (different curves of explo. gases are very closed). catalytic/catharometric cell : Scale of measurement = 0 to 100%LEL / 0 to 100% gas/ volume with an automatic commutation of scale Note: to use this « LEL/volume » version, it’s obligatory to equip the BM25 with an oxygen cell ! Cellule explo classique LEL Reading 100% 50% 0% CH4 Butane H2 NH3 GPL LEL 10 % M ax.

26 BM25:avaible smart blocks

27 BM 25 OPTIONS

28 BM 25 BM 25 : pumping system Avaible in option: the BM25 can be fitted with an included electric pump Associated with a remote sampling system (cap of cells and different king of probes) automatic working pump if a cap fixed…. gaz

29 Optical IR linking for COM 2100 An IR port located on the right side of BM25 allows the linking to a PC serial RS232 or USB cables are avaible COM 2100 software will recognize automatically a linking to a BM25 or to MX2100 common software MX2100/BM25.

30 modules of communication Each following modules wil be installed on demand in the instrument, outputs will be avaible on right side: RS485 4 to 20 mA CATEX ( TOTAL) Others on demand ….

31 BM25 in the field = example of option (legs) Semi-portable or permanently installed

32 BM 25 : CERTIFICATIONS category 1 BM25 (fitted with cells) it’s approved intrinsically safety category 1 (very high level of safety) usable in zones 0 !So usable in zones 0 ! ATEX II 1 GD EEx ia IIC T4 (except with CO2) ATEX I M1 (mines) Other certifications running: INDIA, RUSSIA, CHINA …

33 BM 25 = very high level of safety ! BM25 is a Categorie 1 instrument zones 0The BM25 is a Categorie 1 instrument and can be used in zones 0 and directly in the tank Using without sampling systems And with remote informations of alarms…

34 BM 25 : examples of applications industrial and maintenance sites for manipulations of dangerous substances chemical fire brigades in tunnels, in confined spaces, in sewers … wastewater stations Aircraft maintenance workshops Coal mines In storage tanks, underground storage tanks…