CLASSIFICATION OF HEAT EXCHANGERS

Slides:



Advertisements
Similar presentations
ACTIVE LEARNING PROCESS
Advertisements

Power Plant Engineering
ENERGY CONVERSION MME 9617A Eric Savory
Assumptions: Incompressible substance, B. Negligible heat transfer
HEAT EXCHANGER GUIDED BY: PREPARED BY:
In India 65% of total power is generated by the Thermal Power Stations. Main parts of the plant are 1. CHP.
Convection in Flat Plate Turbulent Boundary Layers P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi An Extra Effect For.
Design Steps : Furnace Of A Steam Generator P M V Subbarao Professor Mechanical Engineering Department Selection of Geometric Parameters….
Heat Exchangers: Design Considerations
Chapter 3.2: Heat Exchanger Analysis Using -NTU method
Vapor and Combined Power Cycles
 A 'heat exchanger' may be defined as an equipment which transfers the energy from a hot fluid to a cold fluid. Here, the process of heating or cooling.
Ch 6 Thermal Energy and Heat. Thermal Energy Temperature & Heat Temperature is a measure of the average kinetic energy of the individual particles in.
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
HEAT EXCHANGERS Day 2.
EGR 334 Thermodynamics Chapter 4: Section 9-10
STEAM CONDENSERS.
Introduction to Heat Exchangers
Reciprocating Compressor
HEAT PIPE HEAT EXCHANGERS
Heat Exchanger Heat exchangers can be described as:
Design Analysis of Plate Heat Exchangers
Gas Turbine Power Plant
Objectives Finish with plotting processes on Psychrometric chart
ME421 Heat Exchanger and Steam Generator Design Lecture Notes 6 Double-Pipe Heat Exchangers.
Heat Exchanger & Classification Prepared by: Nimesh Gajjar
HEAT EXCHANGER.
Outline (1) Heat Exchanger Types (2) Heat Exchanger Analysis Methods
A Presentation on HEAT EXCHANGER DESIGN
HEAT EXCHANGERS.
AIM :- TO STUDY ABOUT STEAM POWER PLANT
Presentation Dungrani rakesh v. Div : a Branch : mechenical Sem : 1 st.
CHAPTER 5: Mass and Energy Analysis of Control Volumes
Heat Exchangers Heat exchangers are used to transfer heat from one stream to another. They are used to heat streams and to cool streams. The streams can.
Generating Stations. Bulk electric power is produced by special plants known as generating stations or power plants. Depending upon the form of energy.
Chapter 11 Heat Exchangers ( ) Heat Exchangers.
P M V Subbarao Professor Mechanical Engineering Department
FOOD ENGINEERING DESIGN AND ECONOMICS
HEAT EXCHANGER SUBMITTED TO: Er. Akash Rana(HOD) Department of Petroleum SUBMITTED BY: Inzamam Ul Haque Mirza Abdul Raheman Mohd. Shahzar Chisti Tahir.
HEAT TRANSFER CHE 3004 Lt. Col. G. Junior Virgo Ext
Professor: Eduardo Cabrera Thermal Engineering Laboratory
7TH SEMESTER ,MECHANICAL ENGINEERING BRANCH
Prepared by : Nishant .A. Raval
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
Professor Eduardo Cabrera
Concentric Tube (double-pipe) Heat Exchangers
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 11 Heat Exchangers.
Heat Exchangers Jorge Seda #84012 José Luis García #69260 Billy Gerena #73656 Robert De Aza #66880 Prof. Eduardo Cabrera ME
Chapter 12B: PROPERTY TABLES, REFRIGERATION CYCLES AND HX 1) Boiling of pure substances: water and steam tables 2) Refrigerant tables 3) Binary mixtures.
HEAT TRANSFER Introduction
FAKULTAS TEKNOLOGI INDUSTRI
Government Engineering College
HEAT EXCHANGERS Red Sea University Faculty of Engineering
Unit 42: Heat Transfer and Combustion
BRAYTON CYCLE AND EFFECT OF INTERCOOLING , REHEAT AND REGENRATION
Heat Pipe | Heat Exchanger Manufactured by Manor
HEAT EXCHANGER.
WHAT IS HX……??? Heat exchangers are equipment that transfer
Heat Exchanger Analysis
Applied Thermal Engineering
Desuperheater Heat Transfer Device Manufactured by Maniks
Maniks Desuperheater a High Performance Energy Saving Product
Chapter 5 The First Law of Thermodynamics for Opened Systems
Concentric Tube (double-pipe) Heat Exchangers
Heat Exchnagers.
9 CHAPTER Vapor and Combined Power Cycles.
HW2 Book problems: 8.5, 8.25, 8.27, 8.28, 8.22  Additional Design Problem (#5): Due October 7th.
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
Heat Exchangers Heat Exchangers.
Chapter 11 HEAT EXCHANGERS Mehmet Kanoglu University of Gaziantep Copyright © 2011 The McGraw-Hill Companies, Inc. Permission required for reproduction.
Presentation transcript:

CLASSIFICATION OF HEAT EXCHANGERS PPT On CLASSIFICATION OF HEAT EXCHANGERS BE Sem- 5 Heat Transfer (2191509) PREPARED BY: GROUP NO. 17 130180119014 BHANA ABUBKAR S. 130180119064 PATEL JAYKUMAR N. 130180119066 PATEL KALPESHKUMAR H. 130180119067 PATEL KUNALKUMAR K. 130180119073 PATEL PARTHKUMAR N. MECHANICAL ENGINEERING DEPARTMENT GOVERNMENT ENGINEERING COLLEGE, DAHOD

HEAT EXCHANGER: A Heat Exchanger may be defined as a Mechanical device which transfer the heat from hot fluid to cold fluid, with maximum rate, with minimum investment and with running cost. Notable examples are: Boilers, super heater and reheaters, Radiators of automobiles, Oil coolers of heat engine, Evaporator and condensor of refrigeration system , Regenerator of gas turbine power plants, Water and air coolers or heaters, Several other industrial processes.

Classification of Heat Exchangers: Many types of heat exchangers have been developed to meet the widely varying applications which are classification based on : Operating principle ( nature of heat exchanger process), Relative direction of fluid motion, Design and constructional features, Physical state of fluid , etc.

A) According to operating principle heat transfer process: According to heat exchange process Non Direct contact type of heat exchanger Recuperator Examples: 1.Radiator 2.Oil heaters etc. Regeneration examples: 1.Open hearth furnace 2.Glass melting furnace etc. Direct contact type of heat exchanger 1.cooling tower 2.condensor etc.

A1) Direct contact type heat exchanger: In direct contact type or open type of heat exchangers the heat transfer take place between two fluids by direct contact between them. There is simultaneous transfer of heat and mass refer fig. 1 The rate of heat transfer is maximum in such case. The use of direct contact type heat exchanger is limited to the situation where mixing between the fluids is either desirable or harmless.

A2) Non – contact type of heat exchangers: In indirect or non-contact type of heat exchanger ,the direct heat exchange between two fluids is not possible as there is no direct contact between two fluids. This type includes regenerators And recoperators. Regenerators: refer fig. no.2 Hot fluid is passed through a Certain medium called matrix. The hot fluids is passing through One sides of matrix, stored in Matrix and given to cold fluid by Rotation of matrix from hot to Cold fluid side. Operation of regenerators is periodic and some mixing of two fluid is possible. It gives quick response to load variation, minimum pressure losses and quite high efficiency.

Recuperators : Refer fig. no. 3 In recuperator, the fluids flow simultaneously on either side of separating wall. The heat transfer occurs between the fluids streams without physical contact or mixing with each other. It is suitable for stationary plants, having more area for heat transfer, cheaper in cost and easy in construction. But the rate of heat transfer is less and have cooling problems.

B)According to the direction of fluid motion Parallel flow or unidirectional flow or concurrent flow Examples: 1.Oil coolers 2. Oil heaters 3.Water heaters Counter flow or counter current flow 1. Used almost in all engineering application Cross flow 1.Cooling units of refrigeration system 2.Automobile radiator

B1)Parallel flow/unidirectional flow: In case of parallel floe heat exchanger, both the fluids are flowing in the same directions. Fig.4 represented the variations in temperature along the length of heat exchanger. Since this type of heat exchanger needs a large area of heat transfer, therefore , it is rarely used in practice. As the two fluids are separated by a wall, this type of heat exchanger may be called parallel flow recuperator.

B2) Counter flow/ Counter current heat exchanger: In case of counter flow heat exchanger , both the fluids are flowing in the opposite directions. The arrangement and temperatures variations along the length of heat exchange for such heat exchangers are shown in fig.

B3)Cross flow heat exchanger: Fig. shows schematic diagrams of common arrangements of cross flow heat exchangers, both fluids are directed at right angles to each others. Fig.(a) represents the case in which there is no mixing of fluids streams which is flowing over the tube(i.e. example: automobile radiator).

Fig(b) represent the mixing of fluid streams at one side (i. e Fig(b) represent the mixing of fluid streams at one side (i.e. over tubes) (Example : condensor of refrigerating system , where air stream will mix together and refrigerent stream does not mix).

C) Mechanical design of heat exchanger surface It is classified as given below: Concentric tube type heat exchangers, Shell and tube, Multiple shell and tube passes, Compact heat exchangers, Finned tube type

C1)Concentric tube type heat exchangers: Fig. represents concentric tube type of heat exchanger. These are also called tubular heat exchangers or tube in tube type of heat exchangers or double pipe heat exchanger.

C2) Shell and tube type heat exchangers: These are also called surface condensor. In shell and tube type heat exchangers, one fluid with flow through shell and other will flow through tube. There is no direct contact between two fluids and the heat will transfer.

A typical exchanger is shown in fig. Multiple shell and tube passes are used for enhancing the overall heat transfer area. Multiple type pass heat exchangers are those which re route the fluid through tubes in opposite direction. Examples are surface condensor in thermal power plants

C3) Compact heat exchangers These are special type of heat exchangers in which heat transfer surface area per unit volume is very large. They are generally employed when convective heat transfer associated with one of the fluids is much smaller than that of associated with the other fluids. These are usually cross floe heat exchangers. .

C4) FINNED TUBE TYPE HEAT EXCHANGERS: When very high rate of heat transfer is required, fins are placed on the one side of heat exchanger which is called finned tube type of heat exchangers. The use of fins enhance heat transfer area and thereby heat exchanges. These heat exchangers are in IC engine cylinder, Gas turbines, refrigerators, electronics equipments, air conditioning systems etc., radiator of an automobiles is a example of said heat exchanger.

D) Physical state of fluids Condensors Evaporators :

D1) Condensors: In condensors, the temperature of hot fluid remains same for the entire length of the heat exchanger but the temperature of cold fluid increases gradually along the length of heat exchanger. Refer fig. The hot fluid reject latent heat which is absorbed by the cold fluid. In case of condensor of thermal power plant, the hot fluid is steam and the cold fluid is cooling water which is gaining the heat and rejecting the heat in cooling towers. Fig. Temperature distribution for condensor

D2)Evaporators: In evaporators, the temperature of cold fluid remains same and the hot fluid temperature drops. The cold fluids receives latent heat from the hot fluid. In case of thermal power plants, the flue gases(hot fluids) reject the heat and the heat and the same is gain by the cold fluid (i.e. water ) in boilers. Fig. Temperature distribution for evaporator

Reference: Heat Transfer by Prof. ALPESH V. MEHTA & Prof. PINKAL G. CHOKSI, Book Of India Heat and Mass Transfer by R K RAJPUT, S. CHAND PUBLICATION https://chemengineering.wikispaces.com/file/view/CrossflowCoolingTwr.png/404939984/CrossflowCoolingTwr.png?_e_pi_=7%2CPAGE_ID10%2C2711513282 http://img.bhs4.com/34/8/3480c89f57e487f05b60ef5e8aacfd33d532a3b1_large.jpg http://img.bhs4.com/ea/9/ea9f5fb4ba42b726243b65dc0bf819f4186bc76f_large.jpg http://www.esru.strath.ac.uk/EandE/Web_sites/12-13/Domestic_flue_gas/images/tmpEA60.png http://me1065.wdfiles.com/local--resized-images/automotive-heat-exchangers/Basic_Hxgr/medium.jpg http://www.real-world-physics-problems.com/images/shell_and_tube_3.png

THANK YOU