ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin

Slides:



Advertisements
Similar presentations
Architecture CAD living sleeping service SPACE PLANNING
Advertisements

UNIT 31 HOME ELECTRICAL SYSTEM
28 Residential Electrical Chapter Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Objectives Explain the characteristics.
4/30/2015 AFCI 9/01/07 Rev 5 1 Arc Fault Circuit Interrupters For NEMA Field Reps.
DAY 4 CHAPTER 3 CONDUCTOR SIZES,TYPES, ETC.. Continuous Load. A load where the maximum current is expected to continue for 3 hours or more. Continuous.
Competency: Draw Electrical Plans
EET Survey of Electronics
EET Survey of Electronics Chapter 24 - Residential Branch Circuit Wiring.
Electrical Power Systems
Electrical Principles and Wiring Materials
Group Formally Known As the Team Anthony Tanios Thai Pham Matthew Buras Jason Preston Julian Moore Physics 211- Final Project Monday, 26 July 2010.
Felicia Castro Olga Kadyra
Exploring CAD - Architectural Electrical Design. OVERVIEW TWO COMPONENTS –POWER –LIGHTS Power to House –Meter –Distribution Panel Box.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Chapter 17 Electrical Plans.
Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 25- Residential Improving your skill in code Look Up Increasing Speed Drill.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
COMMERCIAL ELECTRICAL (Chapter 11)
Copyright 2008 Ted "Smitty" Smith.  Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. 
©Ted “Smitty” Smith This speed drill focuses on subjects that will be required for the journeyman and masters examination arranged by chapter of.
Home Electrical Wiring Types of Receptacles and Wiring them for 120v – 15Amp/20Amp.
Electrical Principles and Wiring Materials Unit #31.
Two Minute Drill Number 23- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
Two Minute Drill Number 22- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 24- Residential.
Electrical Plans.
Electrical Principles and Wiring Materials Original Power Point Created by Casey Osksa Modified by Georgia Agricultural Education Curriculum Office June.
Ag. Mechanics for Beginning Teachers
Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 21- Residential Improving your skill in code Look Up Increasing Speed Drill.
By: Mr. Brock.  Electricity- Source of energy that can be easily converted into light, heat or power  Ampere (Amp)- Unit of measure of the rate of flow.
DOMESTIC ELECTRICAL CIRCUITS National Diploma Mechanical and Electrical Services Construction.
Electrical Safety "Shocking Statistics“  There are approximately 290 accidental electrocutions each year.  An additional 800 people die in fires caused.
HOUSE WIRING Final Review. The Atom Atoms are the basic building blocks of matter that make up everyday objects. A desk, the air, even you are made up.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
Residential Wiring Unit 3 – Installation and Planning.
W. C. “Buster” Hounshell Spring 2002 SWITCHES.
Drafting 2 (Arch) Quiz Review #3 Quiz Review. 1.Dashed lines that follow the counters in a kitchen floor plan most likely represent: A dishwasher Upper.
Joel Moody, MD, PhD, MPH Director of Safety, Risk, Policy and Innovation Why did the requirements for Arc Fault Circuit Interrupters in Dwellings Change?
N.E.C. Installation Techniques and Common Violations
ELECTRICAL SAFETY GA Ag Ed Curriculum Office To accompany the Georgia Agriculture Curriculum Lesson AG-AMI VGP.
Residential Wiring Unit 3 – Installation and Planning Chaps 9-12.
Planning Electrical Circuits Original by Ryan Talton Modified by Georgia Agriculture Education Curriculum Office –June 2004.
Planning The Electrical System
Electrical Principles and Wiring Materials
Electrical Diagrams.
Planning Electrical Circuits
Electrical Principles and Wiring Materials
Electrical Systems Civil Engineering and Architecture
Electrical Principles and Wiring Materials
License Examination Practice Drill
Special-Purpose Outlets— Electric Heating, Air Conditioning
Chapter 12 Branch Circuits and Feeders. Chapter 12 Branch Circuits and Feeders.
Lighting Branch Circuit and Small-Appliance Circuits for Kitchen
Planning The Electrical System
Electrical Systems Electrical Systems
SWITCHES W. C. “Buster” Hounshell Spring 2002.
Planning Electrical Circuits
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Agricultural Systems Technology II
AFCI Protection: AFCI Receptacles and the NEC
Chapter Six Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and.
EET 323 – Electrical System Design Lecture 9: Grounding
Conductor A material, such as copper, that permits the flow of electricity; usually refers to the a wire.
Objectives Review conductor and conduit selection
Wiring Circuits Lesson Plan PSTS: C6-7.
Electrical Principles and Wiring Materials
Smitty’s Two Minute Drill Services, Feeders, and Branch Circuits 1
Presentation transcript:

ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin GA Ag Ed Curriculum Office To accompany the Georgia Agriculture Curriculum Lesson 01422-6.2 July 2002

STANDARDS FOR SAFETY National Electrical Code Local Electrical Code Power Company Requirements Underwriters Laboratory (UL)

NATIONAL ELECTRICAL CODE History of the National Electrical Code Purpose of the NEC How Often the NEC is updated Scope of the NEC Enforcement of the NEC Using the NEC

LOCAL ELECTRICAL CODES Local authorities may adopt NEC May adopt NEC with modifications Local wiring permits and inspections

POWER COMPANY REQUIREMENTS

UNDERWRITERS LABORATORY UL Listed assures product meets minimum safety standards UL Listed does not mean that product is safe for all installations UL Listed is not an indication of quality

BRANCH CIRCUITS Definition of circuit Definition of branch circuit

BRANCH CIRCUITS IN A RESIDENCE Individual Circuit Small Appliance Circuit Laundry Circuit Bathroom Circuit General Purpose Circuit

INDIVIDUAL CIRCUIT Supplies only one outlet or piece of equipment Motors 1/2 horsepower or larger All 240 volt equipment Other equipment such as furnace fan, freezer, television, computer

SMALL APPLIANCE CIRCUIT Serves receptacles for small appliance loads At least two required by NEC Must be 20 ampere circuits No lighting outlets Cannot serve any other room in house

LAUNDRY CIRCUIT Serves only receptacles in laundry room At least one required by NEC Must be 20 ampere circuit May not have lighting outlets May not serve outlets in any other room of house

BATHROOM CIRCUIT Circuit to serve receptacles in bathroom At least one required by NEC Must be 20 ampere circuit May not serve lighting outlets May not serve any other room in house

GENERAL PURPOSE CIRCUITS Serve all lighting outlets in home Serve all receptacles not on one of the other types of circuits May be 15 or 20 ampere (20 ampere preferred) Allow at least one general purpose circuit for every 500 square feet of floor space in house

Determining the Kind, Number and Location of Outlets and Switches in a Wiring System

Lighting Outlet Requirements At least one wall switch controlled outlet in every habitable room in house Stairways consisting of 6 or more steps must have lighting outlet that is wall switch controlled at both floor levels Attics, underfloor space, utility room and basement requirements

RECEPTACLE OUTLET REQUIREMENTS No point along the floor line in any wall space may be more than 6 feet from a receptacle in kitchen, family room, dining room, living room, den, sun room, bedroom, recreation room, or similar room (Receptacles must be no farther than _____ feet apart.)

RECEPTACLE REQUIREMENTS A receptacle must be installed at each kitchen and dining area counter space if the space is wider than 12 inches No point along the wall line of a kitchen counter may be more than 24 inches from a receptacle (Receptacles must be no farther than _____ inches apart)

RECEPTACLE REQUIREMENTS At least one receptacle is required within 36 inches of the outside edge of each basin in bathrooms. All receptacles in bathrooms must have ground fault circuit interrupter protection

RECEPTACLE REQUIREMENTS At least one outdoor receptacle is required All outdoor receptacles must have GFCI protection Outdoor receptacles must be installed in waterproof boxes

RECEPTACLE REQUIREMENTS At least one receptacle is required in the laundry area At least one receptacle is required in a basement. All general use receptacles in an unfinished basement must have GFCI protection

RECEPTACLE REQUIREMENTS At least one receptacle is required in hallways 10 feet or more in length Effective January 1, 2002, all receptacles in a bedroom must have arc-fault circuit interrupter protection

RECOMMENDATIONS FOR OUTLETS AND SWITCHES Receptacles should generally be located approximately above floor line Receptacles preferably should be located near the ends of wall space Lighting outlets in closets should be wall switch controlled Pull chain lighting outlets should be minimized, if used at all

RECOMMENDATIONS FOR OUTLETS AND SWITCHES Wall switches should be generally be located approximately 48 inches above the floor line and on the latch side of doors Three and four way switches should be used to control lights in locations such as rooms having more than one entrance, stairways, halls, basement, covered walkways between the house and garage, etc.

Determining the Number of Outlets On a General Purpose Circuit For calculation purposes, estimate a load of at least 1.5 amps per outlet on the circuit To determine the maximum number of outlets on a 20 amp general purpose circuit: 20 amps (circuit rating)  1.5 amps = 13 outlets (maximum) on the circuit Maximum number of outlets on a 15 amp general purpose circuit = ________?

SELECTING SERVICE ENTRANCE EQUIPMENT Service conductors Service mast Entrance head or weather head Meter base Service entrance cable

Service Entrance Panel Purpose Factors to consider when selecting the service entrance panel Type of panel Size or ampere rating Circuit capacity or number of spaces for connecting circuits

PROVIDING OVERCURRENT PROTECTION Providing a means to interrupt an electrical circuit when the amperage in the circuit becomes excessive Reasons for providing overcurrent protection

SIZE OF OVERCURRENT PROTECTION DEVICE TO USE

PLANNING ELECTRICAL CIRCUITS Wiring symbols

CLASSIFICATION OF CONDUCTORS Grounded conductor Ungrounded conductor Equipment grounding conductor Grounding electrode conductor

Grounded Conductor A current carrying conductor that is connected to the earth Often called the neutral wire Color must be white or natural gray Known as identified conductor Identity must be maintained throughout a circuit and the electrical system

Grounded Conductor NEVER connected to a fuse, circuit breaker, or a switch One grounded conductor must be connected to all 120 volt outlets or equipment

UNGROUNDED CONDUCTOR A current carrying conductor that is not connected to the earth Often called the “hot” wire Color should not be white, gray, or green. Color may be black, red, blue, etc. Circuit breakers (or fuses) and switches are placed on the ungrounded conductor

UNGROUNDED CONDUCTOR One ungrounded conductor must be connected to all 120 volt outlets or equipment. Two ungrounded conductors must be connected to all 240 volt outlets or equipment.

EQUIPMENT GROUNDING CONDUCTOR Under normal conditions, the equipment grounding conductor is never a current carrying conductor. It serves as a path to ground if a fault occurs in electrical equipment or the electrical system May be a bare wire or may have green or green with yellow stripe insulation

EQUIPMENT GROUNDING CONDUCTOR Always connected to the grounding terminal of devices (receptacles, switches, etc.) Always connected to non-current carrying metal parts of equipment and circuits (including all metal boxes)

GROUNDING ELECTRODE CONDUCTOR The large bare copper wire that connects the electrical system to the grounding electrode Size is determined by the size of service entrance cable being used

COLOR CODING OF ELECTRICAL CONNECTIONS Silver or white colored terminal - attach the grounded conductor Copper or brass colored terminal -attach the ungrounded conductor Green colored terminal - attach the equipment grounding conductor