Design of Beam-Column Connections in Steel Moment Frames

Slides:



Advertisements
Similar presentations
BEAMS (FLEXURE) BEAM- COLUMNS SHEAR / CONC. LOADS
Advertisements

Design of Steel and Composite-Structures for Seismic Loading – Safety Requirements, Concepts and Methods – Prof. Dr.-Ing. Ekkehard Fehling, University.
ROTATION CAPACITY OF SEMI RIGID CONNECTIONS
ENCE 455 Design of Steel Structures
REVIEW OF STEEL DESIGN KNOWLEDGE BASE REQUIRED: STRENGTH OF MATERIALS
Reinforced Concrete Design-8
Elastic Stresses in Unshored Composite Section
Lecture 33 - Design of Two-Way Floor Slab System
T6. DESIGN OF REINFORCED CONCRETE BEAM Reinforced concrete framed building T6. Design of reinforced concrete beam page 1. Alaprajz Floor plan Beam: linear.
Reinforced Concrete Flexural Members
Mechanics of Materials – MAE 243 (Section 002) Spring 2008
STESSA 2012 Santiago, Chile Design Considerations for Braced Frames With Asymmetrical Friction Connections - AFC By J. Chanchi, G.A. MacRae, J.G. Chase,
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
LRFD-Steel Design Dr. Ali Tayeh Second Semester
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Connection Design.
Design of Tension Members
Design of Tension Members
PCI 6th Edition Connection Design.
Connection of flange plate with web
Shear - Tensile - Compression Stresses Slip Ted 126 Spring 2007.
CM 197 Mechanics of Materials Chap 20: Connections
Leaning objectives Axial Stress
STEEL DESIGN (I) CE 408 ( 2 – 3 – 3 ) Semester 062
Design and strength assessment of a welded connection of a plane frame
Chapter 11 Flange splice.
Reinforced Concrete Design II
Rehabilitation and maintenance of buildings - 03
STEEL MOMENT RESISTING CONNECTIONS SUBJECT TO EARTHQUAKE LOADING ENCE 710 STEEL STRUCTURES Kirk P. Volovar, P.E. & C. C. Fu, P.E.
Chapter 10 Web splice.
APPENDIX A (RFI) FOR THE FABRICATION OF MULTIPLE STEEL REACTION STRUCTURES FOR NASA-MSFC STRUCTURAL TESTING Mike Roberts 12/2/09.
Chapter 6 Plate girder.
Lecture 5 January 31,  Sudhir K. Jain, IIT Kanpur E-Course on Seismic Design of Tanks/ January 2006 Lecture 5/ Slide 2 In this Lecture Impulsive.
University of Palestine
Static Pushover Analysis
TOPICS COVERED Building Configuration Response of Concrete Buildings
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Moment Connection Requires Bolts Outside the Flanges
T-Stub Connection Component Tests James A Swanson and Roberto T Leon School of Civil and Environmental Engineering Georgia Institute of Technology Atlanta,
Teaching Modules for Steel Instruction TENSION MEMBER Design
Structural Curriculum for Construction Management and Architecture Students 1 Prepared by: Ajay Shanker, Ph.D., P.E. Associate Professor Rinker School.
6- Calculation of shear stress at composite interface: A)Under service load: Strain and stress distributions across composite beam cross- section, under.
Flange Plates to be Welded to Beam Flanges.
Practical Design of PT Buildings
A View of NCSX Structural System and Load Path for the Base Support Structure.
Structural Drafting Shear stress in Bolts. Fastener Loads and Stresses Load:External force applied to a member. Stress: Internal force acting on a member.
Experiments and Simulations of an Innovative Performance Enhancement Technique for Steel Building Beam-Column Connections Machel Morrison Doug Schweizer.
Design of Bracing Connections in Concentrically Braced Frames
UNIT - IV PLASTIC ANALYSIS OF STRUCTURES
IS 800 – 2007 LUG ANGLE TENSION SPLICES SHEAR LAG
DESIGN AND DETAILING FOR EARTHQUAKE LOADS
Built-up Beams and Shear Flow
3 Steel structures 3 Steel structures. If you have any doubts, you can check your textbook, pp
Proposed Balanced Design Procedure
BOLTED CONNECTIONS.
ERT352 FARM STRUCTURES TRUSS DESIGN
An-Najah National University Faculty of Engineering
Outline: Introduction: a ) General description of project b) Materials
FRAMING CONECTIONS Session 3.
CONNECTIONS IN STEEL STRUCTURES
Design of Tension Members
CENF - LBNF cryostat Relevant safety codes
1.6 Allowable Stress Allowable Load < Failure Load
1C2 Conceptual Design of Buildings
CONNECTIONS IN STEEL STRUCTURES IS CRITERIA
BFC Structural Steel and Timber Design
CONNECTION Prepared by : Shamilah
EAT 415 :ADVANCED STEEL BUILDING DESIGN PLATE GIRDER
PLASTIC ANALYSIS OF STRUCTURES
ENCE 455 Design of Steel Structures
Presentation transcript:

Design of Beam-Column Connections in Steel Moment Frames

Observed Damage to Steel Moment Frames in the 1994 Northridge Earthquake

Observed Damage to Steel Moment Frames in the 1994 Northridge Earthquake

Typical Moment Frame Connection Detail Prior to 1994

The SAC Steel Project www.sacsteel.org Funded by FEMA Over 6 years to 2000 $12m research funding Participated by 100s of practicing engineers, university researchers, contractors, materials suppliers, inspectors and building officials

Output of the SAC Steel Project

Prequalified Connection Detail by FEMA 350

Welded Unreinforced Flanges, Welded Web Connection (WUF-W)

Welded Unreinforced Flanges, Bolted Web Connection (WUF-B)

Recommended Weld Access Hole Detail

Typical Details of the Joint Panel Zone - Continuity Plate and Column Web Doubler Plate

Design Procedure of the WUF-B Connections

Beam-Colum Connection Recommended in GB50011-2001: WUF-B Connection – Beam Parallel to Column Web Column through, joint panel zone in the column The 2 welds between the beam flanges and the columns flange must be CJP groove welds The beam web to column flange connection by high strength friction grip bolts via a column connection plate The weld between the column flange and the column connection plate shall be fillet weld both sides, >=5mm, and to develop the full shear strength of the connection plate. If the plate exceeds 16mm in thickness, use double bevel CJP groove welds Continuity plates and beam flanges equal thickness and equal strength

Beam-Colum Connection Recommended in GB50011-2001: WUF-B Connection – Beam Perpendicular to Column Web

Design Process – Step 1 Design Connection for Bending Mu >= 1.3Mp Mp = full plastic moment capacity of the plastic hinge of the beam (column through), or of the column (beam through) Mu = Bending moment resistance capacity of the joint connection provided by the flange connections and based on the design strength of connection If column through and if CJP groove welds are used to connect the beam flanges to the column, this overtrength requirement is considered met

Eurocode 8 Provisions

Design Process – Step 2 Design Connection for Shear Vu >= 1.2(2Mp/ln)+VGb Mp = full plastic moment capacity of the plastic hinge of the beam (column through), or of the column (beam through) ln = clear span of beam VGb=(seismic weight UDL)ln/2, shear force at beam ends, determined by considering static equilibrium of the isolated beam under the seismic weight UDL Vu = Shear resistance capacity of the joint connection provided by the web connection and based on the design strength of connection

Design Process – Step 3 Calculate the Required Panel Zone Thickness and Determine if a Doubler Plate is Needed The shear stress in the panel zone bounded by the flanges of the column and the continuity plates shall meet t = y(Mpb1 + Mpb2)/Vp<=4fyv/3, as well as t = (Mb1 + Mb2)/Vp<=(4/3)fv/gRE Vp = hbhctp is the volume of the panel zone, tp is the panel zone thickness >=(hb + hc)/90 y = 0.6 for Seismic Resistance Class 3 and 4, 0.7 for Seismic Resistance Class 1 and 2 Mb1 and Mb2 = the factored bending moments of beams at the two sides of the joint panel gRE=0.75 fv = design shear strength of steel fyv = 0.58fy, is the yielding stress in shear of steel material Beam-Column Joint Panel Zone Doubler Plate if Required

Design Process – Step 4 Design the Shear Tab and the HSFG Bolts To resist the connection shear force demand 1.3(2Mp/l) FEMA 350 recommends that the bolts should be designed for bearing Chinese code recommends the following for checking the shear resistance of HSFG bolts: Nvb = 0.75nAnbfub Nvb = shear resistance provided by one HSFG bolt n = number of cross sections resisting shear in the bolt Anb= net cross section area of bolt fub = tensile strength of bolt material