COMMON DOH SURVEY CITATIONS UPDATE RANDY BENSON WHS HEALTHCARE QUALITY SERVICE JANUARY 2016.

Slides:



Advertisements
Similar presentations
Safety in Hospitals A Computer – Based Learning Program for Students.
Advertisements

Fire and Environmental Safety Health, healing and hope.
Fire Safety and Prevention
Safety Training Safety First. EXITS All exit doors shall be maintained in operable condition. Exit doors shall not be locked, chained, bolted, barred,
Fire Safety UNIVERSITY of N ORTHERN C OLORADO How to Move Forward/Backward when viewing this slide show To move forward press enter or the down arrow.
EOC: Semi-Annual Review of DOH Survey Citations, The Top 10!
Preparation for the DOH Environment of Care Survey
Utility Management Providence Health System - Oregon Environment of Care.
When A Drill Is Not A Drill: Fire Drills That Keep Your Fire Marshal Happy Randy Benson, Executive Director Rural Healthcare Quality Network.
Annual Evaluation of the Environment of Care (EOC) Program
TOP TEN DOH SURVEY CITATIONS
Randy Benson Executive Director Rural Healthcare Quality Network.
Developing and Strengthening Staff Competency: From Age Specific Competencies to Workplace Violence Training, How Are You Doing?
Interim Life Safety Measures Eleven Administration Actions of Interim Life Safety Measures ÷Ensure free and unobstructed exits. Personnel receive additional.
RHQN Members Conference Call September, 2012 Semi-Annual DOH Survey Update The Environment of Care Randy Benson Executive Director Rural Healthcare Quality.
Vanderbilt University Medical Center Use either the arrows or the “Page Up” and “Page Down” buttons on your computer keyboard to move through the slides.
Safety First: Facility Safety Inspections “Reginald C. Reese VP, Safety and Risk Management.
The Life Safety Surveyor Facility Tour
January 16, 2014 Brad Keyes, CHSP Changes to the 2014 Acute Care & Critical Access Hospital Manuals on Life Safety Compliance.
DOH Survey Citation Update; What’s New, What’s Hot, What’s Not!
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
Randy Benson Executive Director Rural Healthcare Quality Network.
Infection Prevention Fireworks, Non-Clinical IP Issues for CAHs Randy Benson Executive Director RHQN.
1 OFFICE ELECTRICAL SAFETY Environmental Energy Technologies Division (EETD) On the Job Training August 12, 2013.
Fire Prevention and Safety Health Science Class. Rationale: Fires may occur at any time, as a result of overloading wiring, smoking, improper chemical.
FIRE PREVENTION AND SAFETY PRACTICES Health Science.
Air Flow, Humidity and Dust WHS HEALTHCARE QUALITY SERVICE RANDY BENSON, EXECUTIVE DIRECTOR.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Fire Safety and Prevention
HEAD START CHILD AND FAMILY DEVELOPMENT CENTER, INC
If you hear the fire alarm sound, evacuate immediately! Check door for signs of fire Close doors behind you to prevent fire & smoke spread Keep storage.
Health Facilities Planning Seminar Plan Review Division Irvin J. Poke, AIA, Chief Todd Y. Cordill, NCARB, Assistant Chief Providing for Michigan’s Safety.
Business Owners and Managers and the Fire Code
Church Administrators & Emergency Planning
109 th Biennial Inspection Findings Legislative Branch Safety & Health / ADA Working Group January 24, 2006 Thomas H. Seymour, P.E.
The Second Survey Point of Vulnerability How Should I Prepare for the Facility Tour? Healthcare Engineering Consultants.
ELECTRICAL HAZARDS Electricity is an essential of modern life Some work directly with electricity (Engineers, circuit assemblers) Some work indirectly.
Overview of State Hospital Licensing Survey Linda L. Foss PhD, RN Executive Director Clinical Care Facilities Office of Inspections and Investigations.
The Physical Environment Tracers How Should I Prepare for the Physical Environment Tracers? Healthcare Engineering Consultants  Will limit.
All Colby employees work with and around electricity on a daily basis. This Safety Talk focuses on the basic electrical safety elements to protect you.
Fire Safety and Prevention Plan
Safety and Health Working Group Meeting January 24, 2006 Status Report By Stephen Mallinger, CIH.
/0103 Copyright © 2001 Business & Legal Reports, Inc. BLR’s Safety Training Presentations Good Housekeeping 29 CFR (a)
Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities.
Fires need 3 Things To Start Oxygen (Air) Fuel (any material that will burn) Heat (sparks, matches, flames)
Fire No institution is immune from fire. Flood damage can be dried out and restored, stolen property has a chance of being recovered; damage from fire.
2009 OFPC INSPECTION SUMMARY of VIOLATIONS We Need Your Help for the 2009 Inspection!
STANDARD 6.0 The student will analyze the existing and potential hazards to clients, co-workers, and self and will prevent injury or illness through safe.
Fire Extinguishers Hand Held Portables. Fire Extinguishers When faced with a fire, you must make some split second decisions: Do I want to put out this.
RANDY BENSON, PH.D. COMMON DOH SURVEY CITATIONS. Environment of Care and State Fire Marshal DOH is Very Busy DOH Was Running Days Behind Schedule.
Randy Benson Healthcare Quality Service Consultant.
SURVEY READINESS FOR HOUSEKEEPING/ENVIRONMENTAL SERVICES Randy Benson, PhD Consultant WHS Healthcare Quality Service.
1 AS OF:141330DEC15 UNCLASSIFIED OPR: 8A 8A Safety Electrical Safety Awareness Training Note: This training meets the General Electrical Safety Awareness.
RANDY BENSON CONSULTANT HEALTHCARE QUALITY SERVICE How To Keep The Fire Marshal Happy.
Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards Compartmentalization.
Transfer Station Safety OR WORKER AND PUBLIC RISK.
Tulane University - Office of Environmental Health & Safety (OEHS) Electrical Safety For Office, Facility, and Laboratory Employees Tulane University May.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
1 OFFICE ELECTRICAL SAFETY Energy Technologies Area (ETA) On the Job Training May 25, 2016.
Safety and Prevention of Typical Fire Plan
CIHQ - All Rights Reserved 2017
Fire Safety and Prevention Plan
Fire Safety and Prevention Plan
Fire Prevention Planning. Elements of Fire Prevention Planning List all major fire hazards. Proper control of hazardous materials o including flammable.
Fire Door Inspections Qualified Training
Electrical Receptacle Testing
Fire Prevention Safety Department
Fire Safety and Prevention
Fire Prevention and Safety
National Fire Protection Association Update
Presentation transcript:

COMMON DOH SURVEY CITATIONS UPDATE RANDY BENSON WHS HEALTHCARE QUALITY SERVICE JANUARY 2016

COMMON SURVEY CITATIONS ENVIRONMENT OF CARE/FIRE SAFETY ISSUES GOVERNED BY CHAPTER OF THE RCW AND CHAPTER OF THE WAC Inspectors are trained to survey acute care hospitals to confirm minimum compliance with appropriate state regulatory standards. They're looking for indications of system-wide deficiencies that pose risks to patient safety during a hospital visit/stay.

COMMON SURVEY CITATIONS TOP TEN ENVIRONMENT OF CARE CITATION ISSUES : ELECTRICAL WIRING AND EQUIPMENT (FM) CORRIDOR FIRE DOORS (FM) FIRE SPRINKLER TESTING AND MAINTENANCE (FM) FIRE EXTINGUISHERS (FM) ENVIRONMENT OF CARE MANAGEMENT – VENTILATION AND AIR PRESSURE TYPES OF CONSTRUCTION/HAZARDOUS AREAS (FM) SPACE HEATERS (FM) SOILED LINEN (IP) AND TRASH RECEPTACLES (FM) EMERGENCY PREPAREDNESS INFECTION PREVENTION

COMMON SURVEY CITATIONS ELECTRICAL WIRING AND EQUIPMENT (NFPA 70, NATIONAL ELECTRICAL CODE 9, 1, 2.) MISUSE OF EXTENSION CORDS DAISY CHAINS OR PIGGY-BACKED POWER CORDS OBSTRUCTED ELECTRICAL PANELS MISLABELED OR UNLABELED ELECTRICAL CIRCUIT BOXES OUTLETS THAT ARE NOT GROUND FAULT CIRCUIT (GFCI) APPROVED (PEDIATRIC PROTECTED OUTETS) PORTABLE SPACES HEATER USE (LOCATION) OPEN JUNCTION (BREAKER) BOXES (NFPA 70)

COMMON SURVEY CITATIONS CORRIDOR FIRE DOORS (NFPA 101, CMS STANDARD ) DOORS DO NOT CLOSE AND/OR LATCH PROPERLY DOORS PURPOSELY BLOCKED FROM CLOSING PENETRATIONS IN THE DOOR COMPROMISING THE SMOKE RESISTANCE OF THE DOOR (NICKEL RULE) OBSTRUCTIONS IN FIRE EVACUATION ROUTES (EQUIPMENT IN HALLWAYS)

COMMON SURVEY CITATIONS FIRE SPRINKLER TESTING AND MAINTENANCE (NFPA 101, , ,4.6.12, FPA 13, NFPA 25,9.7.5) OVERDUE TESTS/INSPECTIONS MISSING SPRINKLER HEAD ESCUTCHEON PLATES OR RINGS OBSTRUCTED SPRINKLER HEADS AREAS WITH NO SPRINKLER PROTECTION DAMAGED OR OTHERWISE COMPROMISED SPRINKLER HEADS

COMMON SURVEY CITATIONS FIRE EXTINGUISHERS (NFPA , , ) FAILURE TO PROPERLY MAINTAIN FIRE EXTINGUISHERS (MONTHLY INSPECTION OR FINDING A DISCHARGED EXTINGUISHER) NO DOCUMENTATION OF MONTHLY INSPECTION AND TWELVE MONTH RECHARGE (NOTE TIME FRAME)

COMMON SURVEY CITATIONS ENVIRONMENT MANAGEMENT – VENTILATION AND AIR PRESSURE (WAC ) FAILURE TO PROVIDE APPROPRIATE AIR PRESSURE RELATIONSHIPS THROUGHOUT THE FACILITY TO PREVENT RISK OF THE SPREAD OF INFECTIOUS ORGANISMS FAILURE TO PROVIDE ADEQUATE VENTILATION TO REDUCE THE RISK OF OBJECTIONABLE ODOR OR EXCESSIVE CONDENSATION (SURGICAL SERVICES)

COMMON SURVEY CITATIONS TYPES OF CONSTRUCTION/HAZARDOUS AREAS (FM) (NFPA 9.4.1, , , 18, , , , ) IMPROPER OR NO FIRE RATING ON DOORS LACKING ONE-HOUR FIRE-RATED CONSTRUCTION WHEN SPRINKED, MUST HAVE SMOKE RESISTANT PARTITIONS AND DOORS PROPERLY SIZED KICK PLATES ON FIRE DOORS CONSTRUCTION DOES NOT MEET NFPA 200 LIFE SAFETY CODE STANDARDS (BOTH STATE CERTIFICATE OF REVIEW AND CMS STANDARD, DOUBLE CITATION)

COMMON SURVEY CITATIONS SPACE HEATERS (NFPA , ) USE IN PROHIBITED AREAS OF THE HOSPITAL NON-PERMITTED SPACE HEATER USE HOTTER THAN 212 DEGRESS F. NO TIP-OVER SHUT OFF SWITCH PLUGGED INTO EXTENSION CORD OR POWER STRIP TOO CLOSE TO FLAMMABLE MATERIAL

COMMON SURVEY CITATIONS SOILED LINEN AND TRASH RECEPTACLES (NFPA , ) TOO LARGE TOO CLOSE TOGETHER NOT STORED IN A ROOM PROTECTED AS A HAZARDOUS AREA

COMMON SURVEY CITATIONS EMERGENCY PREPAREDNESS (WAC ) FAILURE TO HAVE A CURRENT DISASTER/EMERGENCY PREPAREDNESS PLAN (REVISION IN THE PAST THREE YEARS) (SIGNATURES) FAILURE TO EXERCISE THE PLAN ANNUALLY FAILURE BY 100% OF STAFF TO REVIEW THE PLAN ANNUALLY (BOTH GENERIC AND DEPARTMENT SPECIFIC)

COMMON SURVEY CITATIONS INFECTION PREVENTION (WAC , 1-5) FAILURE OF EOC STAFF TO USE PROPER HAND HYGIENE LACK OF A CURRENT PLAN (REVISIONS WITHIN LAST THREE YEARS) LACK OF DEMONSTRATED INFECTION PREVENTIONIST COMPETENCE LACK OF MANADATED STAFF EDUCATION ON PERTINENT ASPECTS OF IP PLAN LACK OF AN APPROVED LIST OF CLEANERS AND DISINFECTANTS FAILURE TO ROUTINELY INSPECT ALL EOC AREAS (FOOD SERVICES, CLINICAL ANCILLARY DEPTS., ETC)

COMMON SURVEY CITATIONS QUESTIONS & COMMENTS

COMMON SURVEY CITATIONS RANDY BENSON, Ph.D. WASHINGTON HOSPITAL SERVICES HEALTHCARE QUALITY SERVICE CONSULTANT (509)