1 InfraStruXure Tendinte in IT si probleme cu climatizarea in centre de date Mirela Danciu APC Distribution Manager Romania.

Similar presentations


Presentation on theme: "1 InfraStruXure Tendinte in IT si probleme cu climatizarea in centre de date Mirela Danciu APC Distribution Manager Romania."— Presentation transcript:

1 1 InfraStruXure Tendinte in IT si probleme cu climatizarea in centre de date Mirela Danciu APC Distribution Manager Romania

2 Critical Power & Cooling Services Division - 2008 2 Agenda Tendinte in IT si probleme cu climatizarea in centre de date Network-Critical Physical Infrastructure (NCPI) – infrastructuri fizice pentru retele critice Solutia APC: InfraStruXure (ISX) Configuratorul disponibil pentru partenerii autorizati APC Serviciile disponibile la APC Ce facem pentru parteneri

3 Critical Power & Cooling Services Division - 2008 3 Care este cea mai mare problema care apare in centrele de date? 2007 Data Center study 180 respondents

4 Critical Power & Cooling Services Division - 2008 4 Cele mai importante tendinte in IT Consolidarea centrelor de date Aparitia si raspandirea sistemelor modulare (blade servere) VIRTUALIZAREA  Network  Storage  Server: 99 dintre companiile din Fortune 100 sunt clienti VMWare

5 Critical Power & Cooling Services Division - 2008 5 Source: IDC, 2005 0% 25% 50% 75% 100% 200520062007200820092010 Non-Rack OptimizedRack-optimizedBlade Segmentul serverelor blade vazut la nivel mondial / intentia de investitii

6 Critical Power & Cooling Services Division - 2008 6 Caldura in mediul IT Caldura este o forma simpla de energie  Peste 99% din energia consumata pentru alimentarea echipamentelor IT se transforma in caldura. Caldura generata de servere are o tendinta crescatoare.  Un singur sasiu blade server poate disipa 4-5 kW de caldura in camera IT sau centru de date. Mikroprocesszor lég-hűtés A blade szerverek előlről szívják a hideg levegőt

7 Critical Power & Cooling Services Division - 2008 7 Focus pe problema reala Sa furnizezi aer rece nu este o problema. Sa indepartezi aerul cald, DA! Prevenirea recircularii aerului cald in zona de admisie a serverelor, previne supraincalzirea serverelor. Capturarea aerului cald intr-un centru de date este o noua problema in distributia aerului rece Unitatile de climatizare trebuie sa faca o racire eficienta nu numai sa raceasca aerul.

8 Critical Power & Cooling Services Division - 2008 8 Network-Critical Physical Infrastructure (NCPI) – infrastructuri fizice pentru retele critice Cabling Power Cooling Racks and Physical Structure Fire Security and NCPI Reliable Business Operations Process Information Technology People Fiecare nivel depinde de toate de sub el Critical Foundation of Business Continuity

9 Critical Power & Cooling Services Division - 2008 9 In raspuns APC lucreaza sa schimbe modul in care se proiecteaza, instaleaza, functioneaza, conduce si intretine Infrastructura fizica pentru retele critice (NCPI) NCPINCPI Provocarile NCPI High operating and service costs Increasing availability expectations Regulatory requirements Server consolidation Server consolidation Rapid changes in IT technology High density blade server power/heat

10 Critical Power & Cooling Services Division - 2008 10 HIGH- DENSITY Capability Reduced HUMAN ERROR Reduced MTTR Cresterea DISPONIBILITATII si AGILITATII si scaderea COSTURILOR sunt posibile integrand intr-o singura solutie rack-uri, power, climatizare, management, monitorizare, servicii intr-un centru de date standardizat si modular Reduced ENERGY Cost Reduced Non-Energy OPERATING Cost Reduced CAPITAL Cost Deployment SPEED Ability to SCALE Ability to RECON-FIGURE

11 Critical Power & Cooling Services Division - 2008 11 ISX Designer – configuratorul disponibil pentru parteneri pe site-ul APC pentru proiectarea infrastructurilor pentru centre de date

12 Critical Power & Cooling Services Division - 2008 12 ISX Designer – parametrii care pot fi configurati

13 Critical Power & Cooling Services Division - 2008 13 ISX Designer – studiu de caz

14 Critical Power & Cooling Services Division - 2008 14 Servicii disponibile Service in garantie In situatia defectarii in garantie a produselor APC trebuie facut un claim pe web direct de clientul final sau integratorul de sistem pentru o mai mare operativitate; se poate face pe 3 cai: 1. folosind sectiunea "Support" de pe pagina de web publica a APC, la "Ask APC": http://www.apc.com/support/ask.cfm; Se alege din lista de "Help me": troubleshooting http://www.apc.com/support/ask.cfm 2. email la: apchutech@apcc.com 3. telefon la 0800 894 309 – telefon gratuit la CCC Budapesta (operator vorbitor de limba romana) Primele 2 metode sunt recomandate deoarece se inregistreaza automat claimul, si APC trebuie sa raspunda in max. 48 ore Pentru gama de produse monofazate (1 – 10KVA) APC face ADVANCED REPLACEMENT in perioada garantiei

15 Critical Power & Cooling Services Division - 2008 15 Ce facem pentru parteneri Training-uri certificate Programul ORP (opportunity registration program) Incentiv-uri pentru parteneri (prin distribuitori si direct) Promotii pentru parteneri Promotii direct la clientul final Reclame in revistele de specialitate din Romania Newsletters pentru parteneri

16 Critical Power & Cooling Services Division - 2008 16. MULTUMESC