CONGRATULATIONS ON YOUR NEW COCHRAN EMC-20H DIVE COMPUTER Cochran Undersea Technology a division of Cochran Consulting, Inc. Copyright 2000 - 2002 All.

Similar presentations


Presentation on theme: "CONGRATULATIONS ON YOUR NEW COCHRAN EMC-20H DIVE COMPUTER Cochran Undersea Technology a division of Cochran Consulting, Inc. Copyright 2000 - 2002 All."— Presentation transcript:

1 CONGRATULATIONS ON YOUR NEW COCHRAN EMC-20H DIVE COMPUTER Cochran Undersea Technology a division of Cochran Consulting, Inc. Copyright 2000 - 2002 All rights reserved, Protected under one or more Patents, Patents Pending, or Trademarks.

2 PLEASE SELECT THE PRESENTATION YOU WOULD LIKE TO VIEW FROM THE BUTTONS BELOW. AIR ONLY 1-MIX NITROX 2-MIX NITROX EXIT 1-MIX PO2 2-MIX PO2

3 THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE AIR ONLY COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

4 SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1

5 SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1

6 SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1

7 SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1

8 THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.

9 UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE SURFACE INTERVAL SCREEN IS VISIBLE WHENEVER THE UNIT IS AWAKE AND ON THE SURFACE.

10 IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)

11 AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN THE ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = 0 - 2500 2 bars = 5000 - 7500)

12 IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT AUTOMATICALLY GOES TO SLEEP TO CONSERVES BATTERY POWER.

13 LET’S GO DIVING

14 AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.

15 IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

16 DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.

17 Water Temperature Maximum Depth (so far this dive) Current Depth Bottom Time (so far this dive) NDC Time Remain (Time you can stay at current depth without Decompression) Ascent Rate (1 bar = 10-19 fpm) Note NDC Legend DIVE MODE

18 A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED

19 SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

20 COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE

21 WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THE DISPLAYED CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE

22 THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE

23 IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES & DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend

24 THE TEMPerature LEGEND AND VALUES ARE REPLACED BY CEILing LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression

25 IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES. Deco Ceiling NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)

26 ****************************** PLEASE NOTE THAT DEC TIME AND CEIL DEPTH ARE DISPLAYED ONLY WHEN THE DIVER REQUIRES A DECOMPRESSION STOP. IF THE DIVER DOES NOT REQUIRE A DECOMPRESSION STOP, ONLY NDC TIME AND TEMP WILL BE DISPLAYED. IF THE DEC LEGEND AND VALUES ARE REPLACED WITH THE NDC LEGEND AND VALUES, THEN YOU HAVE FULFILLED YOUR DECOMPRESSION OBLIGATIONS. ******************************

27 THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST DIVE INTERVAL HAS PASSED.

28 DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)

29 SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

30 THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

31 TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

32 NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE SIX PROGRAMMING MENUS.

33 WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS PdP, PREDIVE PREDICTION.

34 ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

35 THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)

36 THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU. Conservatism set to 15%

37 THE FIFTH TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU. On Time set to 10 seconds

38 THE SIXTH TOUCH BRINGS THE LOG, LOGBOOK MENU.

39 ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

40 EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

41 NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…

42 THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET. AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. Predict DepthCalculated PO2 (Based on FO2 of 21%) Predict NDC Time (Time you can Stay at predict Depth Without Decompression)

43 PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME. PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF.

44 THE INFORMATION SCREEN GIVES DATA REGARDING THE COMPUTER CONFIGURATION AND THE BATTERY VOLTAGE. Mode Blend Indicator (FO = Air only) Battery Voltage (3.0 Volts)

45 THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.

46 WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash

47 THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.

48 WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE SETTINGS ARE AS INTENDED.

49 IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

50 THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM. Conservatism set to 15%

51 A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 & 3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.

52 THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE TACLITE TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

53 THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE. On Time set to 10 seconds

54 THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number

55 TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

56 IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.

57 OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE

58 PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A NORMAL DIVE

59 ALTERNATE LOGBOOK SCREEN FOR A NORMAL DIVE Battery Voltage (2.9 Volts)

60 PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A DECO DIVE

61 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) FOR A DECO DIVE

62 YOU HAVE JUST COMPLETED A PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

63 A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT www.divecochran.comwww.divecochran.com CLICK ON “PRODUCT MANUALS.”

64 VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE www.divecochran.com AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR ENRICHED AIR NITROX APPLICATIONS. COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING” YOUR COMPUTER.

65 HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE! Click on the door to go back to the main selection screen or click on the stop sign to exit.

66 THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE SINGLE GAS COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

67 SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1

68 SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1

69 SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1

70 SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1

71 THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.

72 AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = 0 - 2500 2 bars = 5000 - 7500)

73 UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. MAIN SCREEN ALTERNATE SCREEN

74 IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)

75 ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Nitrox O2% (Of Blend #1 Set Point)

76 IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.

77 LET’S GO DIVING

78 AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.

79 IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

80 DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.

81 Water Temperature Current DepthCurrent PO2 Bottom Time (so far this dive) NDC Time Remain (Time you can stay At current depth without Decompression) Ascent Rate (4 bars = 40-49 fpm) MAIN SCREEN VISIBLE DURING A DIVE Note NDC Legend

82 ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE Nitrox O2% (Of Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive)

83 A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED

84 SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

85 COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE

86 WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE

87 THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE

88 IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend

89 THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression

90 Deco Ceiling IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 10 FEET FOR 20 MINUTES. NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)

91 ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION Nitrox O2% (Of current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive) Water Temperature

92 THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST-DIVE INTERVAL HAS PASSED.

93 DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)

94 SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

95 THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

96 TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

97 NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE SEVEN PROGRAMMING MENUS.

98 WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

99 ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

100 THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)

101 THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU. Conservatism set to 15%

102 THE FIFTH TOUCH BRINGS UP THE EAn 1 MENU FOR SETTING BLEND#1 O2%. Blend #1 set to 21.0% O2

103 THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” SETTING MENU. On Time set to 10 seconds

104 THE SEVENTH TOUCH BRINGS THE LOG, LOGBOOK MENU.

105 ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

106 EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

107 NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…

108 AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. Predict DepthCalculated PO2 (Based on Blend #1 Set Point) Predict NDC Time (Time you can Stay at predict Depth Without Decompression) THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET.

109 PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF. PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME.

110 Mode Blend Indicator (F1 = 1 FO2) Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN. THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE.

111 THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.

112 WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash

113 THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.

114 WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE SETTINGS ARE AS INTENDED.

115 IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

116 Conservatism set to 15% THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.

117 A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 & 3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, EAn 1 A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE O2% IN BLEND #1.

118 Blend #1 set to 32.0% FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE O2% IN BLEND #1 FROM 21.0 TO 50.0%.

119 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.

120 THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

121 On Time set to 10 seconds THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

122 THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number

123 TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

124 IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.

125 OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES

126 PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A NORMAL DIVE

127 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Nitrox O2% (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE

128 PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A DECO DIVE

129 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Nitrox O2% (Blend #1 Set Point) FOR A DECO DIVE

130 YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

131 A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT www.divecochran.comwww.divecochran.com FIRST CLICK ON “PRODUCT MANUALS.”

132 COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING” YOUR COMPUTER. VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE www.divecochran.com AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR MULTIPLE ENRICHED AIR NITROX APPLICATIONS.

133 HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE! Click on the door to go back to the main selection screen or click on the stop sign to exit.

134 THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE TWO GAS COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

135 SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1

136 SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1

137 SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1

138 SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1

139 THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.

140 AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = 0 - 2500 2 bars = 5000 - 7500)

141 UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE PLACE OF THE UNIT. MAIN SCREEN ALTERNATE SCREEN

142 IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)

143 ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Nitrox O2% (Of Blend #1 Set Point)

144 IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.

145 LET’S GO DIVING

146 AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.

147 IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

148 DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.

149 Water Temperature Current DepthCurrent PO2 Bottom Time (so far this dive) NDC Time Remain (Time you can stay At current depth without Decompression) Ascent Rate (4 bars = 40-49 fpm) MAIN SCREEN VISIBLE DURING A DIVE Note NDC Legend

150 ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE Nitrox O2% (Of Current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive)

151 A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED

152 SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

153 COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE

154 WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE

155 THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE

156 IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend

157 THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression

158 IN THIS EXAMPLE, THE DECO STOP IS REQUIRED AT 10 FEET FOR 20 MINUTES. Deco Ceiling NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)

159 ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION Nitrox O2% (Of current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive) Water Temperature

160 THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST DIVE INTERVAL HAS PASSED.

161 DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)

162 SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

163 THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

164 TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

165 NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE TEN PROGRAMMING MENUS.

166 WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

167 ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

168 THE THIRD COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)

169 Conservatism set to 15% THE NEXT 1&2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.

170 THE FIFTH TOUCH BRINGS UP THE EAn 1, BLEND#1 O2% MENU. Blend #1 set to 21.0% O2

171 THE NEXT TOUCH BRINGS UP THE EAn 2, DECO BLEND O2% MENU. Deco Blend set to 21.0% O2

172 THE SEVENTH TOUCH BRINGS UP THE dEC b, DECO BLEND TIME BENCHMARK MENU. Deco Blend Time Benchmark set to 600 minutes SO WHAT IS A BENCHMARK ?

173 THE NEXT TOUCH BRINGS UP THE dEC d, DECO BLEND DEPTH BENCHMARK MENU. Deco Blend Depth Benchmark set to 0 feet SO WHAT IS A BENCHMARK ?

174 THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU. On Time set to 10 seconds

175 THE TENTH TOUCH BRINGS THE LOG LOGBOOK MENU.

176 ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

177 TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS. EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES.

178 NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…

179 Predict Depth Calculated PO2 (Based on Blend #1 Set Point) Predict NDC Time (Time you can stay At predict depth without Decompression) AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET.

180 PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF. PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME.

181 THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE. Mode Blend Indicator (F2 = 2 FO2) BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN. Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in %

182 THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.

183 WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash

184 THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.

185 WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU. WHEN THIS HAPPENS, THE LAST VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS ALWAYS RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE MENUS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE LIMITS ARE AS INTENDED.

186 IF SO…FOLLOW THE SAME PROCEDURE TO ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

187 THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF CONSERVATISM. Conservatism set to 15%

188 A SIMILAR SEQUENCE OF TOUCHING CONTACTS 1 & 2 WITH A WET FINGER AND 2&3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGIT OF ADDITIONAL CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, EAn 1. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE OXYGEN PERCENTAGE FOR BLEND #1.

189 Blend #1 set to 32.0% FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO CHANGE THE O2% IN BLEND #1 FROM 21.0 TO 50.0%

190 THE NEXT 1 & 2 COIN TOUCH WILL END Blend #1 O2% SETTING AND BRING UP THE EAn 2 MENU WHERE YOU SET THE O2% FOR THE DECO BLEND.

191 SET YOUR DECO BLEND O2 PERCENTAGE ANYWHERE FROM 21.0 TO 99.9% Deco Blend set to 80.0% ANOTHER 1 & 2 COIN TOUCH AND YOU WILL COME TO THE Dec b MENU WHERE YOU SET THE DECO BLEND TIME BENCHMARK.

192 WITH THE SAME SEQUENCE OF 1 & 2 WET FINGER TOUCHES AND 2 & 3 COIN TOUCHES, YOU SET THE DECO BLEND TIME BENCHMARK FROM 10 TO 999 MINUTES Deco Blend Time Benchmark set to 70 minutes SO WHAT IS A BENCHMARK ?

193 THE NEXT CONTACT 1 & 2 COIN BRIDGE WILL TAKE YOU TO THE dEC d MENU WHERE YOU WILL BE ABLE TO CHANGE THE DECO BLEND DEPTH BENCHMARK.

194 FOLLOW THE SAME PROGRAMMING PROCEDURE TO CHANGE THE DECO BLEND DEPTH BENCHMARK FROM 0 TO 99 FEET. Deco Blend Depth Benchmark set to 20 feet SO WHAT IS A BENCHMARK ?

195 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.

196 THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

197 On Time set to 10 seconds THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

198 THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number

199 TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

200 IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.

201 OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES

202 PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A NORMAL DIVE

203 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Nitrox O2% (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE

204 PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A DECO DIVE

205 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Nitrox O2% (Blend #1 Set Point) FOR A DECO DIVE

206 YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

207 A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT www.divecochran.comwww.divecochran.com FIRST CLICK ON “PRODUCT MANUALS.”

208 HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE! Click on the door to go back to the main selection screen or click on the stop sign to exit.

209 WHAT ARE BENCHMARKS? Click here to return to Touch Contact Programming Return BENCHMARKS ARE CONDITIONS THAT MUST BE SATISFIED BEFORE THE GAS SWITCH FROM BLEND #1 TO BLEND #2 WILL OCCUR. THE “Dec b” BENCHMARK IS THE BOTTOM TIME OF THE DIVE AFTER WHICH THE GAS SWITCHING WILL BE ENABLED. ONCE THE PROGRAMMED TIME HAS BEEN SATISFIED, THE GAS SWITCH WILL BE CONTROLLED BY DEPTH THE “Dec d” BENCHMARK IS THE DEPTH OF THE GAS SWITCH. ONCE THE DIVER ASCENDS ABOVE THE PROGRAMMED DEPTH, THE GAS SWITCH FROM BLEND #1 TO BLEND #2 WILL HAPPEN. IF BENCHMARK “Dec b” IS NOT SATISFIED THERE WILL NOT BE A GAS SWITCH.

210 THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE SINGLE PO2 COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

211 SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1

212 SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1

213 SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1

214 SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1

215 THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.

216 AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = 0 - 2500 2 bars = 5000 - 7500)

217 UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. MAIN SCREEN ALTERNATE SCREEN

218 IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)

219 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) PO2 in ATA (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE

220 IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.

221 LET’S GO DIVING

222 AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.

223 IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

224 DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.

225 Water Temperature Current DepthCurrent FO2 Bottom Time (so far this dive) NDC Time Remain (Time you can stay At current depth without Decompression) Ascent Rate (1 bar = 10-19 fpm) MAIN SCREEN VISIBLE DURING A DIVE Note NDC Legend

226 ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE PO2 in ATA (Of Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive)

227 A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED

228 SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

229 COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE

230 WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE

231 THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE

232 IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend

233 THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression

234 Deco Ceiling IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES. NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)

235 ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION PO2 in ATA (Of current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive) Water Temperature

236 THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST-DIVE INTERVAL HAS PASSED.

237 DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)

238 SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

239 THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

240 TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

241 NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE EIGHT PROGRAMMING MENUS.

242 WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR SELECTING EITHER THE FO2 OR PO2 OPERATING MODE. FO2 SCREEN PO2 SCREEN

243 THE SECOND MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION. TOUCH OR BRIDGE CONTACTS 1 AND 2 AGAIN WITH A COIN.

244 ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

245 THE FORTH COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)

246 THE NEXT TOUCH BRINGS THE Con, CONSERVATISM MENU. Conservatism set to 15%

247 THE SIXTH TOUCH BRINGS UP THE PO2 1 MENU FOR SETTING BLEND#1 PO2. Blend #1 set to 0.70 ATA

248 THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” SETTING MENU. On Time set to 10 seconds

249 THE EIGHTH TOUCH BRINGS THE LOG, LOGBOOK MENU.

250 ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

251 EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES. TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS.

252 NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…

253 AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. Predict DepthPO2 Set Point Predict NDC Time (Time you can Stay at predict Depth Without Decompression) THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET.

254 PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF. PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME.

255 Mode Blend Indicator (P1 = 1 PO2) Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN. THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE.

256 THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.

257 WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash

258 THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.

259 WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU ITEM. ONCE THIS HAPPENS, THE VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS STRONGLY RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE SELECTIONS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE SETTINGS ARE AS INTENDED.

260 IF SO…FOLLOW THE SAME PROCEDURE AND ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

261 Conservatism set to 15% THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.

262 A SIMILAR SEQUENCE OF TOUCHING CONTACT 1 & 2 WITH A WET FINGER AND 2 & 3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGITS OF CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1 A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE PO2 IN BLEND #1.

263 Blend #1 set to 0.70 ATA FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO PROGRAM THE PO2 IN BLEND #1 FROM 0.50 TO 1.50 ATA.

264 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.

265 THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

266 On Time set to 10 seconds THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

267 THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number

268 TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

269 IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.

270 OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES

271 PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A NORMAL DIVE

272 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) PO2 in ATA (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE

273 PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A DECO DIVE

274 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % PO2 in ATA (Blend #1 Set Point) FOR A DECO DIVE

275 YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

276 A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT www.divecochran.comwww.divecochran.com FIRST CLICK ON “PRODUCT MANUALS.”

277 COCHRAN UNDERSEA TECHNOLOGY HAS SOLVED THE PROBLEM OF “OUTGROWING” YOUR COMPUTER. VISIT YOUR LOCAL COCHRAN DEALER OR VISIT OUR WEB SITE www.divecochran.com AND LEARN HOW YOUR COMPUTER CAN BE UPGRADED AND ENHANCED FOR MULTIPLE ENRICHED AIR NITROX APPLICATIONS.

278 HAPPY DIVING, HAVE FUN, AND MOST IMPORTANTLY, BE SAFE! Click on the door to go back to the main selection screen or click on the stop sign to exit.

279 THE FOLLOWING PRESENTATION WILL INTRODUCE YOU TO SOME OF THE BASIC FEATURES AND PROGRAMMING SKILLS TO GET THE MOST EFFECTIVE USE OF THE TWO PO2 COCHRAN EMC-20H. PLEASE READ AND UNDERSTAND THE OWNER’S MANUAL. ALSO KNOW AND FOLLOW THE PRINCIPLES AND PRACTICES OF SAFE DIVING.

280 SIDE CONTACTS: Locate the three side contacts. TURN ME ON Contact #3 Contact #2 Contact #1

281 SIDE CONTACTS: TO OPERATE, YOU WILL NEED A METAL OBJECT, SUCH AS A COIN OR DIVE KNIFE BLADE, AND YOUR FINGER. Contact #3 Contact #2 Contact #1

282 SIDE CONTACTS: THE COCHRAN EMC-20H CAN TELL THE DIFFERENCE BETWEEN A METAL OBJECT, SALT WATER, FRESH WATER, AND YOUR WET FINGER. Contact #3 Contact #2 Contact #1

283 SIMPLY BRIDGING CONTACTS 1 AND 2 FOR A COUPLE OF SECONDS WITH YOUR WET FINGER ACTIVATES THE UNIT. A SHORT SERIES OF BEEPS SIGNALS ACTIVATION. Contact #2 Contact #1

284 THE UNIT BEGINS A SELF-TEST TO INSURE THAT ALL SYSTEMS ARE OPERATING CORRECTLY AND ARE “GOOD TO GO.” ALL DISPLAY SEGMENTS ARE VISIBLE AND 5 AUDIBLE SHORT BEEPS ARE PART OF THE SELF- TEST WHEN SUCCESSFULLY COMPLETED.

285 AFTER ACTIVATION AND PRIOR TO DESCENDING BELOW 5 FEET, THE UNIT DISPLAYS TEMPERATURE AND THE SURFACE INTERVAL CLOCK RUNS. ALTITUDE APPEARS IN ASCENT BAR GRAPH Air Temperature Surface Time Barometric Altitude (2500 feet per bar No bars = 0 - 2500 2 bars = 5000 - 7500)

286 UPON COMPLETION OF THE SELF-TEST, THE UNIT ENTERS THE SURFACE INTERVAL MODE. THE ALTERNATE SCREEN CAN BE VIEWED BY TAPPING ON THE FACE OF THE UNIT. MAIN SCREEN ALTERNATE SCREEN

287 IF YOU HAVE RESIDUAL NITROGEN, OR HAVE EXPERIENCED AN ALTITUDE CHANGE, THE SURFACE INTERVAL SCREEN WILL DISPLAY ADDITIONAL INFORMATION. Maximum Depth (of the last dive) Air Temperature Bottom Time (of the last dive) Surface Time (Amount of time since last dive) Time to Fly (Hours before safely flying) Dive of “Day” (Repetitive Dive Number)

288 ALTERNATE SURFACE INTERVAL SCREEN WITH RESIDUAL NITROGEN Battery Voltage (2.9 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % PO2 in ATA (Of Blend #1 Set Point)

289 IF A DIVE IS NOT INITIATED WITHIN ONE HOUR, THE UNIT CONSERVES BATTERY POWER AND AUTOMATICALLY GOES TO SLEEP.

290 LET’S GO DIVING

291 AT 5 FT. OF DEPTH, THE DIVE MODE TAKES PRIORITY AND AUTOMATICALLY REPLACES OTHER PROGRAMMING AND DISPLAY MODES.

292 IF ANYTHING IS NOT UP TO THE HIGHEST OPERATING STANDARD, OR IF BATTERY POWER IS INADEQUATE, THE UNIT WILL TURN ITSELF OFF. CHECK YOUR OWNER’S MANUAL FOR BATTERY REPLACEMENT DETAILS.

293 DURING A DIVE, THE FOLLOWING DATA IS AVAILABLE IN A LARGE, EASY TO READ DISPLAY.

294 Water Temperature Current DepthCurrent FO2 Bottom Time (so far this dive) NDC Time Remain (Time you can stay At current depth without Decompression) Ascent Rate (1 bar = 10-19 fpm) MAIN SCREEN VISIBLE DURING A DIVE Note NDC Legend

295 ALTERNATE SCREEN THAT MAY BE VIEWED DURING A DIVE PO2 in ATA (Of Current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive)

296 A “TWO MINUTE WARNING” IS ISSUED WHEN NO– DECOMPRESSION TIME REACHES 2 MINUTES. THE REMAIN TIME NUMBERS FLASH THE WARNING LEGEND APPEARS AND FLASHES AN AUDIBLE ALARM WILL BE ISSUED

297 SHOULD A NO-DECOMPRESSION LIMIT BE EXCEEDED, THE COMPUTER AUTOMATICALLY ENTERS THE DECOMPRESSION MODE. STAYING AT THE SAME DEPTH OR DEEPER AFTER THE 2 MINUTE WARNING WILL CAUSE THE UNIT TO ENTER THE DECOMPRESSION MODE.

298 COCHRAN DOES NOT INTEND FOR THIS UNIT TO BE DELIBERATELY USED FOR DECOMPRESSION DIVING. HOWEVER, IF YOU PLAN TO PERFORM DECOMPRESSION DIVES, WE RECOMMEND THAT YOU HAVE ADEQUATE TRAINING, BACK UP TABLES, AND AT LEAST TWO IDENTICAL COCHRAN COMPUTERS. DECOMPRESSION MODE

299 WHILE IN DECOMPRESSION MODE, THE VALUES IN THE UPPER LEFT HAND REMAIN TIME BOX ALTERNATE BETWEEN THE TIME REQUIRED AT THAT CEILING DEPTH AND THE TOTAL TIME REQUIRED TO COMPLETE ALL DECO STOPS. AT THE 10 FOOT CEILING, TOTAL TIME AND STOP TIMES MAY BE THE SAME AND APPEAR NOT TO ALTERNATE. DECOMPRESSION MODE

300 THE CEILING REPRESENTS A DEPTH ABOVE WHICH THE DIVER MUST NOT ASCEND, UNTIL SUFFICIENT TIME HAS PASSED, IN ORDER TO MINIMIZE THE RISKS OF DECOMPRESSION SICKNESS. THE DEPTH OF THE REQUIRED CEILINGS START AT 10 FEET AND INCREASE IN 10 FOOT INCREMENTS AS THE DECOMPRESSION OBLIGATION INCREASES. DECOMPRESSION MODE

301 IN DECOMPRESSION MODE, THE NDC LEGEND AND VALUES ARE REPLACED BY DECOMPRESSION TIMES, DEC. Deco Stop Time (Alternates between Total Deco Time and time at current Stop) NDC Time Remain (Time you can stay at current depth without Decompression) No-Decompression Time Decompression Time Note NDC Legend Note DEC Legend

302 THE TEMP LEGEND AND VALUES ARE REPLACED BY CEIL LEGEND AND VALUES. Deco Ceiling Water Temperature Note TEMP Legend Note CEIL Legend Don’t go above this depth for optimum Decompression

303 Deco Ceiling IN THIS EXAMPLE, A DECO STOP IS REQUIRED AT 20 FEET FOR 12 MINUTES. NOTE THAT THE NDC LEGEND HAS CHANGED TO DEC Deco Stop Time (Alternates between Total Deco Time and time at current Stop)

304 ALTERNATE SCREEN VIEWABLE DURING DECOMPRESSION PO2 in ATA (Of current Blend Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % Max Depth (of current dive) Water Temperature

305 THE 10 MINUTE PERIOD FOLLOWING A DIVE IS CALLED THE POST-DIVE INTERVAL. THE SURFACE INTERVAL SCREEN IS VISIBLE. THE SURF LEGEND WILL FLASH UNTIL THE 10 MINUTE POST DIVE INTERVAL HAS PASSED.

306 DISPLAYED DATA Air Temperature Maximum Depth (of the last Dive) Surface Time (Amount of time since last Dive) Bottom Time (of the last Dive) Dive of “Day” (Repetitive Dive Number) Time to Fly (Hours before safely flying) (Post Dive Interval and Surface Interval)

307 SHOULD ANOTHER DIVE BE STARTED BEFORE THE 10 MINUTE POST DIVE INTERVAL IS COMPLETE, THE DIVE WILL BE CONSIDERED AN EXTENSION OF THE PREVIOUS DIVE. PROGRAMMING IS DISABLED. NOTE: DURING THE 10 MINUTE POST DIVE INTERVAL, TOUCH CONTACT

308 THE COCHRAN EMC-20H HAS MANY FEATURES THAT ENHANCE DIVER SAFETY WITH MANY USER PREFERENCES. THE DIVER CAN CUSTOMIZE THE COMPUTER TO BETTER REFLECT THE DIVE CONDITIONS AND INDIVIDUAL STYLE OF DIVING. MANY OF THESE FEATURES ARE PROGRAMMABLE AT THE DIVE SITE. OTHER FEATURES WILL REQUIRE THE ANALYST SOFTWARE INTERFACE.

309 TOUCH CONTACT PROGRAMMING MODE CAN ONLY BE ACCESSED WHEN THE UNIT IS IN THE SURFACE INTERVAL.

310 NOW, GRAB THE BATTERY REPLACEMENT TOOL THAT WAS INCLUDED WITH YOUR COCHRAN EMC-20H. IT CAN BE RECOGNIZED BECAUSE IT LOOKS AND SPENDS EXACTLY LIKE A U.S. QUARTER. THIS FIRST TIME THROUGH THE PROCEDURE, WE ARE SIMPLY GOING TO LOOK AT THE TEN PROGRAMMING MENUS.

311 WITH THE SURFACE INTERVAL SCREEN DISPLAYED, TOUCH OR BRIDGE CONTACTS 1 AND 2 WITH A COIN. THE FIRST MENU TO APPEAR IS FOR SELECTING EITHER THE FO2 OR PO2 OPERATING MODE. FO2 SCREEN PO2 SCREEN

312 TOUCH OR BRIDGE CONTACTS 1 AND 2 AGAIN WITH A COIN. THE SECOND MENU TO APPEAR IS FOR PdP, PREDIVE PREDICTION.

313 ANOTHER SIMILAR TOUCH WITH A COIN BRINGS THE InF, INFORMATION MENU.

314 THE FORTH COIN TOUCH BRINGS THE dEP AL, DEPTH ALARM MENU. (Depth Alarm set to 124 feet)

315 Conservatism set to 15% THE NEXT 1&2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF ADDITIONAL CONSERVATISM.

316 THE SIXTH TOUCH BRINGS UP THE PO2 1 MENU FOR SETTING BLEND#1 PO2. Blend #1 set to 0.70 ATA

317 THE NEXT TOUCH BRINGS UP THE PO2 2, DECO BLEND PO2 MENU. Deco Blend set to 1.30 ATA

318 THE EIGHTH TOUCH BRINGS UP THE dEC b, DECO BLEND TIME BENCHMARK MENU. Deco Blend Time Benchmark set to 600 minutes SO WHAT IS A BENCHMARK ?

319 THE NEXT TOUCH BRINGS UP THE dEC d, DECO BLEND DEPTH BENCHMARK MENU. Deco Blend Depth Benchmark set to 0 feet SO WHAT IS A BENCHMARK ?

320 THE NEXT TOUCH BRINGS UP THE TAC, TACLITE DWELL OR “ON TIME” MENU. On Time set to 10 seconds

321 THE TENTH TOUCH BRINGS THE LOG LOGBOOK MENU.

322 ANOTHER TOUCH RETURNS YOU TO THE SURFACE INTERVAL SCREEN.

323 TOUCH CONTACTS 1 AND 2 WITH THE COIN AGAIN AND THE PdP MENU REAPPEARS. EACH PROGRAMMING OPTION OFFERS ADDITIONAL DATA OR OPPORTUNITIES FOR PROGRAMMING YOUR PERSONAL DIVING PREFERENCES.

324 NOW TOUCHING CONTACTS 1 AND 2 WITH A WET FINGER WILL ALLOW THE ADDITIONAL DATA TO APPEAR ON THE SCREEN. FOR EXAMPLE…

325 AS SHOWN HERE, AFTER TWO MORE TOUCHES THE PREDICTED TIME IS FOR A DEPTH OF 50 FEET. Predict DepthPO2 Set Point Predict NDC Time (Time you can Stay at predict Depth Without Decompression) THE PREDICTED NDC TIME BEGIN AT 30 FEET, EACH ADDITIONAL WET FINGER TOUCH INCREASES THE PREDICT DEPTH BY 10 FEET.

326 PREDICTIONS ARE TERMINATED WHEN THE NO-DECOMPRESSION TIME PREDICTION REACHES TWO MINUTES OR A DEPTH OF 320 FEET IS REACHED. BRIDGING CONTACT 1 AND 2 WITH A COIN TAKES YOU TO THE NEXT MENU, InF. PRE-DIVE PREDICTIONS ARE EFFECTED BY RESIDUAL NITROGEN LOADING AND CHANGE WITH SURFACE INTERVAL TIME.

327 THE INFORMATION SCREEN GIVES DATA REGARDING CNS AND OTU OXYGEN TOXICITY ISSUES, UNIT CONFIGURATION AND BATTERY VOLTAGE. Mode Blend Indicator (P2 = 2 PO2) BRIDGING CONTACTS 1 & 2 WITH A WET FINGER WILL ACCESS THE INFORMATION SCREEN. Battery Voltage (3.0 Volts) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in %

328 THE NEXT 1 & 2 COIN TOUCH BRINGS UP THE DEPTH ALARM PROGRAMMING MENU. THE NEXT WET FINGER 1 & 2 TOUCH STARTS THE 1’S DIGIT FLASHING. The Digit being Programmed will Flash Until it is set and you Move on to the next Digit.

329 WHEN FLASHING, THE DIGIT IS INCREASED BY ONE WITH EACH COIN TOUCH BETWEEN CONTACTS 2 & 3. The Digit being Programmed will Flash

330 THE NEXT 1 & 2 WET FINGER TOUCH STARTS THE 10’S DIGIT FLASHING AND MAKES IT AVAILABLE FOR CHANGE. A COIN TOUCH BETWEEN 2 & 3 INCREASES THE VALUE BETWEEN 0 AND 9. TO PROGRAM THE 1OO’S DIGIT START IT FLASHING BY TOUCHING 1 & 2 WITH YOUR WET FINGER. WITH THE 100’S DIGIT FLASHING, BRIDGE CONTACTS 2 & 3 WITH A COIN UNTIL THE DESIRED VALUE IS REACHED.

331 WHEN CONTACT 1 AND 2 ARE NEXT BRIDGED WITH A COIN, THE SCREEN ADVANCES TO THE NEXT MENU. WHEN THIS HAPPENS, THE LAST VALUES PROGAMMED ARE STORED IN THE COMPUTER. IT IS ALWAYS RECOMMENDED THAT YOU SCROLL THROUGH ALL OF THE PROGRAMMABLE MENUS PRIOR TO BEGINNING A DIVE TO ENSURE THAT THE LIMITS ARE AS INTENDED.

332 IF SO…FOLLOW THE SAME PROCEDURE TO ADD A BIT OF CONSERVATISM TO YOUR DIVING. ADD FROM 0% - 50% TO ANY OR ALL DIVES. SUPPOSE THAT YOU’RE A BIT DEHYDRATED, A LITTLE FATIGUED, SOMEWHAT OVERWEIGHT, AND HAVE AN OLD INJURY. MAYBE YOU HAVE ANOTHER CONDITION WHICH MIGHT PREDISPOSE YOU TO DECOMPRESSION ILLNESS…..

333 THE NEXT 1 & 2 COIN TOUCH WILL END DEPTH ALARM PROGRAMMING AND OPEN THE MENU USED FOR PROGRAMMING A PERCENT OF CONSERVATISM. Conservatism set to 15%

334 A SIMILAR SEQUENCE OF TOUCHING CONTACTS 1 & 2 WITH A WET FINGER AND 2&3 WITH A COIN WILL ALLOW YOU TO PROGRAM THE 1’S AND 10’S DIGIT OF ADDITIONAL CONSERVATISM. A CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, PO2 1. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE PO2 VALUE FOR BLEND #1.

335 Blend #1 set to 0.70 ATA FOLLOW THE PROCEDURE DESCRIBED PREVIOUSLY TO CHANGE THE PO2 IN BLEND #1 FROM 0.50 TO 1.50 ATA.

336 THE NEXT 1 & 2 COIN TOUCH WILL END Blend #1 PO2 SETTING AND BRING UP THE PO2 2 MENU WHERE YOU SET THE PO2 FOR THE DECO BLEND.

337 SET YOUR DECO BLEND PO2 IN ATA ANYWHERE FROM 0.50 TO 1.50. Deco Blend set to 1.30 ATA ANOTHER 1 & 2 COIN TOUCH AND YOU WILL COME TO THE Dec b MENU WHERE YOU SET THE DECO BLEND TIME BENCHMARK.

338 WITH THE SAME SEQUENCE OF 1 & 2 WET FINGER TOUCHES AND 2 & 3 COIN TOUCHES, YOU SET THE DECO BLEND TIME BENCHMARK FROM 10 TO 999 MINUTES Deco Blend Time Benchmark set to 70 minutes SO WHAT IS A BENCHMARK ?

339 THE NEXT CONTACT 1 & 2 COIN BRIDGE WILL TAKE YOU TO THE dEC d MENU WHERE YOU WILL BE ABLE TO CHANGE THE DECO BLEND DEPTH BENCHMARK.

340 FOLLOW THE SAME PROGRAMMING PROCEDURE TO CHANGE THE DECO BLEND DEPTH BENCHMARK FROM 0 TO 99 FEET. Deco Blend Depth Benchmark set to 20 feet SO WHAT IS A BENCHMARK ?

341 THE NEXT CONTACT 1 & 2 COIN TOUCH TAKES YOU TO THE NEXT MENU, TAC dl. A WET FINGER TOUCH WHILE ON THIS SCREEN BEGINS THE PROCEDURE FOR SETTING THE TACLITE “ON TIME” OR DWELL.

342 THE TACLITE IS ACTIVATED BY TAPPING ON THE FACE OF THE COMPUTER. THIS UNIQUE DESIGN LETS YOU READ THE DATA IN LOW- LIGHT CONDITIONS WITHOUT THE WORRIES OF OVER-DEPLETING THE BATTERY. ALSO, “NO WORRIES MATE” ABOUT A SWITCH THAT COULD POTENTIALLY BREAK OR LEAK. YOU SIMPLY PROGRAM THE LIGHT TO REMAIN ON FOR WHATEVER TIME YOU CHOOSE.

343 On Time set to 10 seconds THE TACLITE FACTORY SETTING IS 10 SECONDS, YOU CAN CHANGE THIS TIME FROM 1-98 SECONDS. SETTING IT TO 00 AND THE TACLITE WILL NEVER TURN ON. A SETTING OF 99 AND THE LIGHT IS ON WHENEVER THE EMC-20H IS AWAKE.

344 THE NEXT COIN TOUCH OF CONTACTS 1 & 2 OPENS THE LOGBOOK MODE. THE WET FINGER BETWEEN 1 & 2 WILL ALLOW VIEWING OF DIVE DATA FOR THE MOST RECENT 512 DIVES. Logbook Dive Number

345 TAPPING THE FACE OF YOUR COCHRAN EMC- 20H WILL ACTIVATE AN ALTERNATE SCREEN, WHICH DISPLAYS THE DATE AND TIME OF THE SELECTED DIVE. DayMonthYear Minutes 00 to 59 Hour 00 to 24 THIS DIVE WAS STARTED AT 14:26 (2:46 P.M.) ON 18 December 2001

346 IMPORTANT DATA FROM COMPLETED DIVES IS EASILY AVAILABLE ONCE IN THE LOGBOOK MODE.

347 OVERALL DIVE NUMBER MINIMUM WATER TEMPERATURE SURFACE INTERVAL BEFORE DIVE BOTTOM DIVE MINIMUM NDC TIME FASTEST RATE OF ASCENT MAXIMUM CEILING (DECO DIVE) MAXIMUM DEC TIME (DECO DIVE) ENDING BATTERY VOLTAGE DATE AND TIME OF DIVE CNS and OTU OXYGEN TOXICITY VALUES

348 PRIMARY LOGBOOK SCREEN Water Temperature (Minimum recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) NDC Time Remain (Minimum NDC time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A NORMAL DIVE

349 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) PO2 in ATA (Blend #1 Set Point) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % FOR A NORMAL DIVE

350 PRIMARY LOGBOOK SCREEN Deepest Deco Ceiling (Recorded during the dive) Maximum Depth (of the dive) Surface Time (Amount of time since last dive) Bottom Time (of the dive) DEC Time Remain (Maximum Deco time during the dive) Ascent Rate (Maximum recorded on dive 40 - 49 fpm) FOR A DECO DIVE

351 ALTERNATE LOGBOOK SCREEN Battery Voltage (2.9 Volts) Water Temperature (Minimum recorded during the dive) OTU Oxygen Toxicity in % CNS Oxygen Toxicity in % PO2 in ATA (Blend #1 Set Point) FOR A DECO DIVE

352 YOU HAVE JUST COMPLETED A BRIEF PRESENTATION ON SOME OF THE MANY FEATURES AND BENEFITS OF THE COCHRAN EMC-20H COMPUTER. YOUR OWNER’S MANUAL GOES INTO GREATER DETAIL REGARDING THESE AND OTHER VALUABLE FEATURES, ALL DESIGNED AND DEVELOPED TO SUPPORT A SAFER, MORE ENJOYABLE DIVING EXPERIENCE.

353 A COMPLETE COPY OF THE OWNER’S MANUAL CAN BE OBTAINED FROM OUR WEBSITE. VISIT www.divecochran.comwww.divecochran.com FIRST CLICK ON “PRODUCT MANUALS.”