© 2007 Ideal Industries www.idealindustries.com 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer.

Similar presentations


Presentation on theme: "© 2007 Ideal Industries www.idealindustries.com 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer."— Presentation transcript:

1 © 2007 Ideal Industries www.idealindustries.com 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer

2 © 2007 Ideal Industries www.idealindustries.com 2 of 32 Intro To Ideal 800 Power Analyzer Objective of Demo Gain a understanding of the Analyzer and Software. –Interactive or real time measurements –Setting up for Data logging –Download of data and Software This presentation was done using a hair dryer as a load, and a line splitter with a standard DMM test lead set for quick and easy set-up. This was done for demonstration purposes to get familiar with the analyzer before attaching analyzer to an unknown circuit. (Hair dryer is not in Demo Case)

3 © 2007 Ideal Industries www.idealindustries.com 3 of 32 Intro To Ideal 800 Power Analyzer Simple Set-up To For Learning the IDEAL Analyzer. Attach the Black lead to N input and the Red lead to the VL1 input of the analyzer. Connect the leads to the 2 test point holes on the line splitter, and plug splitter in to a 120V receptacle. Attach one of the clamps to the IL1, then clamp around the x10 loop of the line splitter. Use a hair drier as a load.

4 © 2007 Ideal Industries www.idealindustries.com 4 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation First, the analyzer may be used in an interactive or real time mode –The interactive functions do not hinder the performance of the analyzer mode of operation –To begin Lets make Sure that the Analyzers is not taking “storing” data. –You should see STOP in the lower left corner of the display

5 © 2007 Ideal Industries www.idealindustries.com 5 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation Table Display Mode –Turn on unit and observe Display –After a few moments you should see on the analyzer the Table Display Note Measurement –Vp-n –A –KW –etc

6 © 2007 Ideal Industries www.idealindustries.com 6 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation Large Display Mode –Press ESC –Note the reading on the display –This display can be configured to read any three values that the analyzer can measure –Press Enter

7 © 2007 Ideal Industries www.idealindustries.com 7 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation To make changes to the display you must de-select the measurement you don’t desire –Use arrow keys to Identify measurement and press SET to select (On) or de- select(Off) Remember only three can be selected, so to start, you must first de-select at least one –Press Enter to return to Large display screen

8 © 2007 Ideal Industries www.idealindustries.com 8 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation BAR Graph Mode –Press ESC –Note the reading on the display –This display can be configured to read any of the three phase measurements on the analyzer –Press Enter

9 © 2007 Ideal Industries www.idealindustries.com 9 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation Use the Up and Down Arrow key to select your desired function {Vp-p, Vp- n, A, KW etc.} –In this example Select A for amperes –Enter

10 © 2007 Ideal Industries www.idealindustries.com 10 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation Set graph ZERO value to the desired value –For example set ZERO value to 0 –Use arrow keys and the SET key to select Value on key pad in the bottom right of screen Set graph Full Scale value to the desired value –For example, set Full Scale value to 130 –Use arrow keys and the SET key to select Value on key pad in the bottom right of screen. Return to Bar Graph display and note changes

11 © 2007 Ideal Industries www.idealindustries.com 11 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation Waveform Display –Note the display –Phase Values are to the left of screen –Adq is hi-lited Press enter to acquire new waveform data –Use the arrow keys to select a phase measurement –Example: A L1 –Press enter

12 © 2007 Ideal Industries www.idealindustries.com 12 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation Waveform Zoom –Note display –Use left & right arrow keys to move cursor across waveform –Note cursor data reading –Press Enter

13 © 2007 Ideal Industries www.idealindustries.com 13 of 32 Intro To Ideal 800 Power Analyzer Interactive Operation Harmonics Bar Graph display –Note Display reading –Use left and right arrow keys to move between harmonics –Note changes in the reading

14 © 2007 Ideal Industries www.idealindustries.com 14 of 32 Intro To Ideal 800 Power Analyzer Power Analyzer setup This screen shows how the analyzer is set up –Right screen defines setup perimeters –Left screen is how this analyzer is set up Setup PerimetersAnalyzer Setup Analyzer Setup screen

15 © 2007 Ideal Industries www.idealindustries.com 15 of 32 Intro To Ideal 800 Power Analyzer Before you Begin Initial Considerations 61-805 Unit Set-up –Set run/stop to STOP –Check Files –Clear ENERGY value –Clear Maximum & Minimum values –Check or Set Time and Date –Name of file with desired file type It is a good idea to delete all files to have maximum memory available. Check to make sure that any files in analyzers have been transferred or backup to the Power Provision software supplied with analyzer

16 © 2007 Ideal Industries www.idealindustries.com 16 of 32 Intro To Ideal 800 Power Analyzer Menus of the Analyzer

17 © 2007 Ideal Industries www.idealindustries.com 17 of 32 Intro To Ideal 800 Power Analyzer Unit Setup-Password Setup Menu –Press SET –Enter Password [<] [SET] [^] [SET]

18 © 2007 Ideal Industries www.idealindustries.com 18 of 32 Intro To Ideal 800 Power Analyzer Unit Setup- Run/Stop & Clear From Main Menu select RUN- Press enter –Use arrow keys to select Stop- press enter –Esc or arrow back to Main Menu Select CLEAR-press enter –Select energy and clear –Select MAX MIN and clear –Esc or arrow back to Main Menu

19 © 2007 Ideal Industries www.idealindustries.com 19 of 32 Intro To Ideal 800 Power Analyzer Unit Setup-Period & Trigger ESC or Arrow key back to RECORD Menu Select PERIOD – Press enter –Set the period from 15 minutes {default is 00:15:00} to 1 minute [ 00:01:00 ] –Record may also be triggered by level or time. –Set Trigger to Auto

20 © 2007 Ideal Industries www.idealindustries.com 20 of 32 Intro To Ideal 800 Power Analyzer Unit Setup- File Name ESC or Arrow key back to RECORD Menu Select NAME – Press enter –Use the arrow keys to move around the keyboard on screen –Use set to enter each character (8 chars max) –Press enter – Esc or arrow back to SETUP Menu

21 © 2007 Ideal Industries www.idealindustries.com 21 of 32 Intro To Ideal 800 Power Analyzer Unit Setup-Clock From the SETUP Menu select CLOCK – Press enter –Set Date as shown Date / Month/ Year dd/mm/yy –Set Time as shown hours:minutes:seconds hh:mm:ss Not necessary each time unit is set up

22 © 2007 Ideal Industries www.idealindustries.com 22 of 32 Intro To Ideal 800 Power Analyzer Unit Setup- Current Clamps From Main Menu select SETUP - Press enter From Setup Menu select MEASURE - Press Enter In Measure Menu select TR.REL - Press Enter –REL. A Primary CT value { CPR-1000 ratio is 1000A/2V, set to [ 1000 ]} –REL.V Primary and Secondary voltage values should be set to 1 “Do Not Change” Not necessary each time unit is set up

23 © 2007 Ideal Industries www.idealindustries.com 23 of 32 Intro To Ideal 800 Power Analyzer Analyzer Setup screen Check the Analyzer setup for desired configuration –Check ratios: –Check Filename : –Check recording parameters –Check Trigger: Setup PerimetersAnalyzer Setup

24 © 2007 Ideal Industries www.idealindustries.com 24 of 32 Intro To Ideal 800 Power Analyzer Before you Begin Make your phase to phase connections Confirm proper connection of analyzer to {L1,L2,L3} Check KW readings Should not have negative power –Set run/stop to Run {When you are ready to start}

25 © 2007 Ideal Industries www.idealindustries.com 25 of 32 Intro To Ideal 800 Power Analyzer Software Insure the analyzer power communication cable is connected to the power interface adapter and the adapter is plugged in Insure serial cable is connected to the power interface adapter and your computer Connect analyzer power/interface adapter to the analyzer and adapter. –Use only the cables supplied with analyzer

26 © 2007 Ideal Industries www.idealindustries.com 26 of 32 Intro To Ideal 800 Power Analyzer Software Short Cut Icons –Energy Graphs energy data –Data Chart Graphs any stored data –Communication Sets device perimeters –Config Com Sets device port –Export Data Export read data file to be used by other applications –Read Power Analyzer Reads data file from analyzer

27 © 2007 Ideal Industries www.idealindustries.com 27 of 32 Intro To Ideal 800 Power Analyzer Software Before you begin, make sure your software matches your Analyzers communication setting. To view analyzers setting, go to the SETUP screen last sections Example:Com: 9600 /no/8/1

28 © 2007 Ideal Industries www.idealindustries.com 28 of 32 Intro To Ideal 800 Power Analyzer Software Next is the proper setting of your COM port. If you aren’t sure check through Windows Control Panel which port is available. In this example:COM1 –The modem was on com2

29 © 2007 Ideal Industries www.idealindustries.com 29 of 32 Intro To Ideal 800 Power Analyzer Software Power Vision software was designed to make it easy to convert data taken by the analyzer and present it in easy to understand Table or graphical format.

30 © 2007 Ideal Industries www.idealindustries.com 30 of 32 Intro To Ideal 800 Power Analyzer Software Table Data

31 © 2007 Ideal Industries www.idealindustries.com 31 of 32 Intro To Ideal 800 Power Analyzer Software Graph Data

32 © 2007 Ideal Industries www.idealindustries.com 32 of 32 Intro To Ideal 800 Power Analyzer Software Harmonics


Download ppt "© 2007 Ideal Industries www.idealindustries.com 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer."

Similar presentations