Presentation is loading. Please wait.

Presentation is loading. Please wait.

Test Procedure: ECS (E1/Eth), SAM2, SAM1.5 & Access

Similar presentations


Presentation on theme: "Test Procedure: ECS (E1/Eth), SAM2, SAM1.5 & Access"— Presentation transcript:

1 Test Procedure: ECS (E1/Eth), SAM2, SAM1.5 & Access
INALA TECHNOLOGIEs Test Procedure: ECS (E1/Eth), SAM2, SAM1.5 & Access Version 1.0

2 Testing Summary Set up SAM2.
Set up ECS (E1/Eth) communication controller. Test communication to SAM1.5 or SAM2 unit via ECS (E1/Eth) coms Controller Test communication to Access Control unit via ECS (E1/Eth) coms Controller SAM Training

3 SAM2 Set UP – Via RS232

4 SAM2 – RS232 RS232 Communication Test;
Connect a straight RS232 cable between the Lap Top and the SAM2 RS232 port(DB9 Connector on front panel Open SAM2 ECT Select “Com Port” and double click on “Password” SAM Training

5 SAM2 – Set up via RS232 continued
RS232 Communication Test; Cont; Active communication will be shown on the bottom left as indicated with the RED circle until it says “received” Click on “Load Config” and select the applicable config file. Click on “Update SAM” and wait until SAM has been updated – This can be seen on the bottom left as indicated with the RED circle until it says “received” Click on “Sync Time” Click on “Get Config” and ensure that SAM2 shows you the current date and time. Capture SAM2 Serial number. Click on “Update” Click on “Set Config” 4 7 3 5 6 1 2 SAM Training

6 SAM2 – Set up via RS232 continued
1 RS232 Communication Test; Cont; Click on “Alarm Configuration” tab Select “RS485” under “Coms Config” Click on “Set” Click on “Get Config” Click on “Set Config” Check that “Intruder” alarm is number “9” Check that “Movement” alarm is number “11” Close SAM2 ECT 4 5 3 2 SAM Training

7 ECS (e1/eth) communication Controller Set-UP

8 ECS(E1/Eth) Coms Controller – Set up
Connect a Straight RS232 cable the Lap Top and the ECS(E1/ETH) Coms Controller diagnostics port. Open ECS(E1/ETH) ECT Insert “User name” and “Password” Select “Serial Communication and click on “Login” 1 2 3 4 SAM Training

9 ECS(E1/Eth) Controller – Set up
4 ECS(E1/ETH) Set Up: Click on “Find” to connect to unit Check that the units has the latest Firmware version being “ ” If Not on latest version, upgrade to latest version Click on “Down Load” Capture the IP address as indicated Click on “Set” Click on “Site Inventory” 2 1 3 1 SAM Training

10 ECS(E1/Eth) Coms Controller – Set up
ECS(E1/ETH) Set Up: Capture ECS(E1/ETH) Coms Port setup as per screen print Click on “Set” on the “Network” tab once done. SAM Training

11 Testing Communication to the SAM or Access Control unit
via the ECS(E1/Eth) communication controller

12 Laptop – Set up SAM Training Laptop Set Up:
Your Laptop IP address needs to be changed so that it is within range of the coms controller Connect LAN cable between the Coms controller and the Laptop Open Network settings Click on “Local area Connection” Click on “Properties” Select “Internet protocol Version 4(TCP/IP). Click on “Use the following IP Address” Capture the IP address – IP address will be the same as the Coms controller except the last digit must differ The Subnet mask and gateway IP must be the same as the coms controller Click on “OK” SAM Training

13 SAM2 Communication Test
via the ECS(E1/Eth) communication controller

14 SAM2 – Communication test via ECS2 Communication Controller – “RS485”
RS485 Communication Test; Connect a LAN cable between the Lap Top and the ECS(E1/Eth) LAN port Open SAM2 ECT Select “TCP” and insert the IP address of the ECS(E1/Eth) and Port 301 and double click on “Password” SAM Training

15 SAM2 – Communication test via ECS2 Communication Controller – “RS485”
RS485 Communication Test; Cont; Active communication will be shown on the bottom left as indicated with the RED circle until it says “received” SAM Training

16 SAM1.5 Communication Test
via the ECS2 communication controller

17 SAM1.5 – Communication test via ECS2 Communication Controller – “RS485”
RS485 Communication Test; Connect a LAN cable between the Lap Top and the ECS(E1/Eth) LAN port Open SAM2 ECT Select “TCP” and insert the IP address of the ECS(E1/Eth) and Port 301 and double click on “Password” SAM Training

18 SAM1.5 – Communication test via ECS2 Communication Controller – “RS485”
RS485 Communication Test; Cont; Active communication will be shown on the bottom left as indicated with the RED circle until it says “received” SAM Training

19 Access Control Communication Test
via the ECS2 communication controller

20 Access Control – Communication test via ECS2 Communication Controller – “RS485”
RS485 Communication Test; Cont; Click on “TCP” and insert IP address of the ECS(E1/Eth). Click on “Connect” Click on “Logon” Click on “Open Door” Click on “Get Version” Click on “Get Time” Click on “Log off” Click on “Exit” Responses should be received as indicated in the Red circle 1 2 3 6 7 4 5 6 SAM Training

21 Thank you