Presentation is loading. Please wait.

Presentation is loading. Please wait.

Hybrid IP PBX.

Similar presentations


Presentation on theme: "Hybrid IP PBX."— Presentation transcript:

1 Hybrid IP PBX

2 KX-TDA100/200

3 KX-TDA Hybrid IP-PBX The ultimate solution for the seamless synchronisation of voice and data. Vastly improved feature set and even greater ease of operation. Completely new architecture with Panasonic’s legendary reliability. Integrated DECT portable phones. PC-Phone and PC-Console via USB.

4 KX-TDA Hybrid IP-PBX Advanced Networking.
Tie Lines VPN Q-Sig VoIP Higher Call Centre functionality. Multi-connect CTI.

5 Hybrid IP-PBX The Concept: New Technology Quick Development
VoIP QSIG Wireless xDSL Open Architecture Hybrid IP-PBX Global Business using Internet Expandability Call Centre with CTI / IVR / CRM New Architecture Worldwide Software Ver. Unified Messaging VM/Fax-mail/ Quick Development New Customer Needs

6 Convergence of Telephone & IT Networks
Telephony Network IT Network Remote Maintenance Remote Maintenance Networking CTI Server Panasonic PSTN/ISDN Internet Personal CTI DPT Panasonic Hybrid IP-PBX Office CTI Router USB CTI Client SLT LAN H.323 IP Telephony Wireless Data Hybrid of Technologies

7 KX-TDA Line-up TDA ports TDA ports TDA ports

8 KX-TDA System Outline The Main Unit consists of a Basic Shelf that includes an MPR (Main Processor) card. * Power Supply must be ordered separately according to requirements. The ‘Free Slot’ architecture allows a wide variety of CO, Extension and other peripheral cards to be installed easily into the system’s remaining slots.

9 KX-TDA System Outline The TDA200 can be configured to a maximum of 216 ports. 128 Extns / 128 Lines max. The TDA100 can be configured to an absolute maximum of 108 ports. 64 Extns / 64 Lines max.

10 KX-TDA Configurations
Free Slot Architecture TDA100 TDA200

11 KX-TDA System Capacity - 1
Max. Port 216 108 36 Initial Configuration 0-CO / 4-Hybrid port Free Card Slot 10-slot 5-slot CO 2-slot [4-port] Optional Card Slot 1-slot 1-slot EXT. 2-slot [8-port] 1-slot [4-port] Power Supply Medium (M) Small (S) Max. Trunk Port 128 64 8 or 12 Max. CO (PSTN) 128 64 8 Max. E&M (Tie Line) 32 16 N/A Max. BRI, S0-Bus 64 (128-ch) 32 (64-ch) 6 (12-ch) Max. PRI, Internal PRI 4 (120-ch) 2 (60-ch) N/A Max. E1 4 (120-ch) 2 (60-ch) N/A Max. IP Gateway Card 4 (16-ch) 2 (8-ch) 1 (2-ch)

12 KX-TDA System Capacity - 2
Max. Port 216 108 36 Free Card Slot 10-slot 5-slot 4-Hybrid port 1 x 4-Port Slot 2 x 8-Port Slot Optional Card Slot 1-slot 1-slot Max. Extension 128 64 28 Max. SLT 128 64 24 Max. D-PT (T7600 series, T7565, T7560) 128 64 24 Max. D-PT including Digital XDP 128 64 24 Max. Old D-PT (Note-1 ) (T75/T74/T72 series) 32 (128 : Note2 ) 16 (32 : Note3 ) 4 (24 : Note4 ) Max. DECT-Cell Station 32 (128-ch) 16 (64-ch) 4 (16-ch) Note-1: An old DPT Consumes 4 times the power of a new DPT. Therefore, calculate 1 old DPT as 4 DPTs. Note-2: Requires Optional Power Supply L. Note-3: Requires Optional Power Supply M. Note-4: Requires Optional Power Supply SX.

13 KX-TDA System Capacity - 3
Other Accessories Max. DECT CS (Antenna) 32 16 4 Note : A DECT CS belongs to Extension Type and is counted as an Extension. Max. DECT PS (Cordless) 128 128 24 Max. TVP system 2 2 1 Max. Doorphone 16 8 4 Max. Door Opener 16 8 4 Max. External Relay 16 8 N/A Max. External Sensor 16 8 N/A Max. Voice MSG(OGM) Ch. 16 8 2 Max. BGM / MOH Input 2 2 1 Max. External Paging 2 2 2 Max. RS232C / SMDR 1 1 1 Max. USB 1 1 1 Max. Ethernet For CTI or Programming 1 1 1 Max. PC Console 8 8 N/A

14 1 KX-TDA200/100 MPR card MPR : Main Processor card (Pre-installed)
Same unit for both TDA100 and TDA200 SD (Secure Digital) card (16 Mb Pre-installed) - System Software - Customer Data - Replaceable - ISDN Remote Maintenance to update Main Software SD Slot RMT Analogue Modem Analogue Modem card (Optional) - Max. 56K bps (V.90) USB Interface (Pre-installed) - Programming / CTI USB I/F MEX Expansion Memory Expansion Memory card (Optional) - Available from Version 1.1 Software - Extension Capacity Expansion Serial I/F RS232-C / V.24 Interface (Pre-installed) - Programming / SMDR 1

15 KX-TDA200/ Trunk cards Trunk cards (Optional) Installed in any “Free slot” LCOT 8 LCOT 16 8 or 16 Analogue CO card - Polarity Reversal E&M 8 8 E&M card - Type 5 CID8/PAY8 Caller ID card for 8 CO (FSK/DTMF) 12/16KHz Detection BRI 4 BRI 8 PRI 30 4 or 8 Basic Rate ISDN card 1 Primary Rate ISDN card (30-ch) - RJ45 / BNC E1 (30-ch) IP-GW 4 1 E1 card - RJ45 / BNC 4 IP Gateway card - 10 Base-T - Occupies 2-slots

16 KX-TDA200/100 Extension cards
Extension cards (Optional) Installed in any “Free slot” 8 Digital Hybrid Line card - Supports 8 DPT and 8 SLT, or 8 APT. - 2 Power Failure port - 8 DTMF Receiver - XDP - DXDP (from V1.1) DHLC8 DLC 8 DLC 16 8 or 16 Digital Line card - Cabling : 500 m - DXDP (from V1.1) SLC8 SLC16 MSLC16 8 or 16 SLT Line card - 2 or 4 Power Fail ports - 8 or 16 DTMF Receivers - 48V (1500m) 16 SLT with Message Lamp - 90-Volt Neon Lamp - 4 Power Fail ports - 16 DTMF Receivers CSINF4 CSINF 8 4 or 8 DECT-CS Interface - Cabling : Up to 1000 m

17 KX-TDA200/100 Optional cards
Option card Installed in “Option Slot” & any “Free slot” OPB 3 Optional card mounting base board - Houses 3 small optional cards MSG4 / DPH4 / EIO4 and ECHO16 4 Doorphone / Door Opener card DPH4 4-Ch. Message card - Total 8 min. Max. 64 Msgs MSG4 16-Ch. Echo Canceller card - Suppresses echo signal - Required for 1) Multiparty Conference from party to 8-party (Especially for Analogue CO and SLT customers) 2) Analogue CO to CO Transfer 3) Network-based echo ECHO16 4 Sensor Input / 4 Relay Output card (Ver.1.1) EIO4 CTI-LINK CTI Interface Card - 10 Base-T

18 TDA System Configuration - Cards & Slots
Extension Card DHLC8 DLC8, DLC16 SLC8, SLC16 Max. 8 Cards Max. 4 Cards CSINF4 CSINF8 Max. 4 Cards Max. 2 Cards Free Slot Limitation Total Max. 8 Cards Max. 4 Cards Trunk Card LCOT8, LCOT16 BRI4, BRI8, E1 PRI30, E&M4 IP-GW4 Max. 8 Cards Max. 4 Cards System Limitation One PRI30 or One E1 card counts as “2-cards” Free Slot TOTAL Max. 10 Cards Max. 5 Cards PRI30 / E1 count as “1-card” (Not 2) Option OPB3, CTI-Link Max. 4 Cards Max. 2 Cards System TOTAL Max. 11 Cards Max. 6 Cards

19 TDA System Configuration - OPB3 Cards
DOOR4 DOOR2 MSG4 Max. 4 Cards Max. 2 Cards Options ECHO Max. 2 Cards Max. 1 Cards

20 TDA System Configuration - Power Factor
Power Supply PWS-S For TDA100 64 Power Factor PWS-M For TDA100/200 128 PWS-L For TDA200 512 Terminals and Cards Power Factor PT T7600 / T7565 / T7560 (New DPT) T7400 / T7200 (Old DPT) APT (T73xx) / DSS (T73/74xx) 1 4 4 SLT SLC8 card SLC16 card MSLC16 card DHLC8 card 8 16 16 8 DECT CS (TDA0142) 4 ISDN-Extension (2ch) 2 KX-TVP Port (2ch) 1

21 TDA System Configuration - Calculation-1
Step 1 Requirement Step 2 Slot Calculation Step 3 Unit Selection Physical Slots T76xx 30 DLC16 x 2-cards = 32 port 2 Extension SLT 60 SLC16 x 4-cards = 64 port 4 BRI8 x 2-cards = 16 port ISDN BRI 15 2 Trunk Analogue CO 4 LCOT8 x 1-card = 8 port 1 Total 9 Slots is Required for this Configuration. TDA200 Step 4 Power Factor Calculation Power Factor T76xx / T7565 / T7560 PT 1 x 30 = 30 Total Power Factor 94 SLT SLC16 card 16 4 64 x = Therefore, is Required ! PWS-M

22 TDA System Configuration - Calculation-2
Step 1 Requirement Step 2 Slot Calculation Step 3 Unit Selection Physical Slots T76xx 4 Total DPT ports = = 14 DLC16 x 1-card = 16 port T74xx 10 1 Extension SLT 15 SLC16 x 1-card = 16 port 1 DECT CS 6 CSINF8 x 1-card = 8 port 1 ISDN BRI 7 Total BRI ports = = 10 BRI 8 x 2-cards = 16 port Trunk 2 ISDN Extension 3 Total 5 Slots Step 4 Power Factor Calculation is OK for this Configuration. TDA100 Power Factor T76xx / T7565 / T7560 T74xx / T72xx PT 1 x 4 = 4 4 x 10 = 40 SLC8 card SLC16 card SLT 8 x = Total Power Factor 90 16 1 16 x = DECT CS (TDA0142) 4 6 24 x = Therefore, is Required ! PWS-M ISDN-Extension (2ch) 2 3 6 x =

23 TDA System Configuration - Calculation-3
Step 1 Requirement Step 2 Slot Calculation Step 3 Unit Selection Physical Slots T76xx 25 DLC16 x 2-cards = 32 port 2 Extension SLT 15 SLC16 x 1-card = 16 port 1 DECT CS 5 CSINF8 x 1-card = 8 port 1 Trunk BRI8 x 2-cards = 16 port 2 ISDN BRI 14 Total 6 Slots TDA200 is Necessary ! Step 4 Power Factor Calculation Power Factor PT T76xx / T7565 / T7560 1 x 25 = 25 SLT Total 61 SLC16 card 16 1 16 Power Factor x = DECT CS (TDA0142) 4 5 20 x = Therefore, is Required ! PWS-M

24 TDA System Configuration - Calculation- 4
Step 1 Requirement Step 2 Slot Calculation Step 3 Unit Selection Physical Slots T76xx 4 Total DPT ports = = 14 DLC16 x 1-card = 16 port 1 T74xx 10 Extension Extension SLC16 x 1-card = 16 port 1 SLT 15 DECT CS 6 CSINF8 x 1-card = 8 port 1 ISDN BRI 7 Total BRI ports = = 10 BRI8 x 2-cards = 16 port Trunk Trunk 2 ISDN Extension 3 Total 5-Slots Step 4 Power Factor Calculation PT T76xx / T7565 / T7560 T74xx / T72xx APT / T73/74xx DSS 1 x 4 = 4 4 10 40 TDA100 is OK for this configuration. x = 4 x = SLT SLC8 card SLC16 card MSLC16 card DHLC8 card 8 x = 16 1 16 x = Total 90 Power Factor 16 x = 16 x = Therefore, is Required ! PWS-M DECT CS (TDA0142) 4 6 24 x = ISDN-Extension (2ch) 2 3 6 x = KX-TVP Port (2ch) 1 x =

25 TDA System Configuration - Calculation- 5
Step 1 Requirement Step 2 Slot Calculation Step 3 Unit Selection Physical Slots T76xx 15 Total DPT ports = = 18 DLC16 x 1-card = 16 port DHLC8 x 2-cards = 16 port SLC16 x 3-cards = 48 port 1 T7640 3 Extension Extension 2 T7330 10 SLT 51 3 PRI 1 PRI30 x 1-card = 30 port 1 Trunk Trunk ISDN Extension 8 BRI8 x 1-card = 8 port 1 Step 4 Power Factor Calculation Total 8-Slots PT T76xx / T7565 / T7560 T74xx / T72xx APT / T73/74xx DSS 1 x 15 = 15 4 x = TDA200 is Required 4 13 52 x = SLT SLC8 card SLC16 card MSLC16 card DHLC8 card 8 x = 16 3 48 x = Total 163 Power Factor 16 x = 16 x 2 = 32 Therefore, is Required ! PWS-L DECT CS (TDA0142) 4 x = ISDN-Extension (2ch) 2 8 16 x = KX-TVP Port (2ch) 1 x =

26 KX-TDA100/200 Hardware

27 KX-TDA200/100 MPR RMT KX-TDA0196 MEX KX-TDA0105 SD (Built-in )
Card Name Function Card Configuration FLASH: 512KB SDRAM: 8MB SRAM: 1.0MB * (TDA MB) Slide SW ( Initialise / Normal) TSW is in both MPR and LPR. MPR CPU : SH7709A (133MHz/32bit) (Main Central Processing Unit ) RMT Analogue modem card Modem IC (V.90 support) MAX:33.6Kbps (Remote Maintenance Trunk) (This card is unnecessary when ISDN remote is used) KX-TDA0196 Flash: 8MB SDRAM: 8MB SRAM: 1MB (Version 1.1) MEX Reserved for feature expansion (Memory Expansion) KX-TDA0105 SD Pre-installed software System will not initialise if an SD card is not installed -System data Back-up Memory size: 16MB (Built-in ) (Secure Digital Card)

28 System Initialize Switch
Main Processor Card [MPR] Pager 1 Pager 2 LED1 (BATT Alarm) LED2 (SD Access) Reset Switch System Initialize Switch USB Port MOH2 MOH1 *ASIC : Application Specific Integrated circuit (Includes TSW) SD Card Controller Flash ROM SRAM USB Controller ASIC* SDRAM CPU

29 KX-TDA200/100 DHLC8 DLC16 (DLC8) MSLC16 SLC16 (SLC8) CSIF8 Card Name
Max use Function Card Configuration DHLC8 CPU : SH-1(12.288MHz) Flash : 512KB External RAM : 1KB Internal 128KB External TDA200 8 TDA100 4 8 DPT/ APT/SLT/DSS Console ports 2 power fail ports 8 DTMF receivers Level control per port *Software downloadable from PBX ( Digital Hybrid Line) KX-TDA0170 DLC16 (DLC8) 16(8) port DPT card DSS console can be connected Level control per port *Software downloadable from PBX CPU : SH-1(12.288MHz) Flash : 512KB External RAM : 1KB Internal 128KB External TDA200 8 TDA100 4 (Digital Proprietary Line) KX-TDA0172 (0171) MSLC16 Message Waiting Lamp control 16 DTMF receivers 4 power fail ports Level control per port TDA200 8 TDA100 4 NO CPU (SLT 90VMW Lamp 48V cct.) KX-TDA0175 SLC16 (SLC8) TDA200 8 TDA100 4 16(8) DTMF receivers 4(2) power fail ports Level control per port NO CPU (8-port SLT Line 48V) KX-TDA0174 (0173) For DECT(4ch) / 2.4GHzSS-FH(3ch) *Software downloadable from PBX Level control per port (CSIF8 is counted as 2 EXT. cards with standard power unit.) CSIF8 CPU : SH-1(12.288MHz) Flash : 512KB External RAM : 1KB Internal 128KB External (8-port Cell Station I/F ) TDA200 4 TDA100 2 KX-TDA0144

30 CSIF8 Card Trans for the transmission LED1 (Card status)
Echo Canceling ASIC (CS-LPR communication) RJ45 ASIC (MPR-LPR communication) CPU Flash ROM

31 KX-TDA200/100 LCOT16 (LCOT8) CID/PAY8 CID8 E&M 8 E1 Card Name Max use
Function Card Configuration LCOT16 (LCOT8) Polarity reversal detection 4 (2) power fail ports Level control per port (-6dB ~ +3dB per 3dB) NO CPU TDA200 8 TDA100 4 (Loop Start Trunk) 2-daughter board on LCOT16 KX-TDA0181 (0180) 1-daughter board on LCOT8 CID/PAY8 TDA TDA100 8 (Caller ID/Pay Tone) NO CPU CO Caller ID type -> Bell/ETSI/DTMF type KX-TDA0189 CID8 (Caller ID ) TDA TDA100 8 CO Caller ID type -> Bell/ETSI/DTMF type NO CPU KX-TDA0193 Type5 DTMF/Pulse Dial Signaling Type: Continuous E&M / Pulsed E&M *Software downloadable from PBX CPU: SH-1 (12.288MHz) FLASH: 512KB RAM: Internal 1KB SRAM: 128KB E&M 8 TDA200 8 TDA100 4 (E&M TIE line card) KX-TDA0184 E1 TDA200 4 TDA100 2 Level control (-9dB ~ 0dB per 3 dB) *Software downloadable from PBX MFC-R2 / DTMF / Pulse Dial Signaling Type: Digital R2 / Continuous E&M / Pulsed E&M RJ45/BNC (Slide SW) (ITU-T / ANSI ) Connector:RJ45 (EIA/TIA) CPU : SH-1(12.288MHz) FLASH : 512KB SRAM : 512KB DSP mounted (30ch E1 TIE line card) KX-TDA0188

32 KX-TDA200/100 BRI8 (BRI4) PRI30 BRI2 DHLC4 LCOT4DHLC4 CID4 Card Name
Max use Function Card Configuration BRI8 (BRI4) TDA200 8 TDA100 4 CPU : SH-1(12.288MHz) FLASH : 512KB SRAM : 512KB RJ45 (ISDN Basic) Extension / CO trunk per port *Software downloadable form PBX Level control (-9dB ~ 0 dB per 3 dB) Euro-ISDN / ETS (Q-SIG) KX-TDA0288 (0284) CO Trunk / Extension *Software Downloadable from PBX Level control (-9 dB ~ 0 dB per 3 dB) Impedance: selective (75/120ohms) Euro-ISDN / ETS / NT1 PRI30 CPU : SH-1(12.288MHz) FLASH : 512KB SRAM : 512KB Coaxial/RJ45 (Slide SW) TDA200 4 TDA100 2 (ISDN Primary) (Q-SIG) KX-TDA0290 CPU : SH-1(12.288MHz) Flash : 512KB External RAM : 1KB Internal 128KB External RJ45(CO trunk side) BRI2 DHLC4 2-port ISDN basic I/F for Extension / CO trunk per port DPT / APT / SLT / DSS / Console card with 4-port. TDA200 4 TDA100 2 (Ver. 1.1) (Q-SIG) KX-TDA???? CPU : SH-1(12.288MHz) Flash : 512KB External RAM : 1KB Internal 128KB External RJ45 (CO trunk side) LCOT4DHLC4 4-port analog LCOT (polarity reversal) 1 power fail port 4-Ports DPT / APT / SLT / DSS / Console TDA200 4 TDA100 2 (Ver. 1.1) KX-TDA???? CID4 (Ver. 1.1) TDA200 4 TDA100 2 CO Caller ID type -> Bell/ETSI/DTMF type NO CPU KX-TDA????

33 KX-TDA200/100 IP-GW4 CTI-LINK Card Name Max use Function
Card Configuration IP-GW4 Supports VoIP H.323 V.2 Voice coded: G.729a, G723.1 FAX:G3 64 Kbps , Physical I/F: 10 BASE-T (occupies 2 slots) TDA200 4 TDA100 2 (Q-SIG) KX-TDA0480 Card Name Max use Function Card Configuration Ethernet card for CTI communication Data controlled Physical I/F: 10BASE-T CPU SH7709A(133MHZ) FLASH:512KB SDRAM:8MB CTI-LINK TDA200 1 TDA100 1 (LAN I/F) KX-TDA0410

34 IP-GW4 Card DSP CPU 10 Base T Ethernet Port SD RAM FPGA*
RS232C Maintenance Port (Communication between Lower card and Upper card) Upper Card ( VoIP/H.323 control ) Lower Card ( Communication with MPR ) *FPGA: Field Programmable Gate Array

35 CTI-LINK Card LAN Controller LED1 (Card status) Flash Memory LED2
(Link status) Trans SD RAM RJ45 ASIC (MPR-LPR communication) CPU

36 KX-TDA200/100 Not in AL version OPB3 MSG4 DPH4 DPH2 (-G) EIO4 ECHO16
Card Name Max use Function Card Configuration OPB3 CPU : SH1(12.288MHz) ROM : 512KB(External) RAM : 1KB(internal) 128KB(External) TDA200 4 TDA100 2 Max 3 option cards *Software Downloadable from PBX (Optional base card) KX-TDA0190 OGM for DISA / Queuing / Wake up Calls / Internal hold melody DTMF detection, CO-CO conversation DTMF repeater functions MSG4 TDA200 4 TDA100 2 NO CPU Total 16 min. Max. 64 messages for System (4-channels) KX-TDA0191 DPH4 TDA200 4 TDA100 2 4-port Door-phone & Door-opener card Door-phone (T30865) NO CPU KX-TDA0161 DPH (-G) TDA200 8 TDA100 4 2-port Door-phone & Door-opener card For Germany D-phone I/F NO CPU KX-TDA0162 EIO4 (Ver. 1.1) TDA200 4 TDA100 2 (External I/O) 4 Outputs (Relay) Inputs Used for external relay / sensor NO CPU KX-TDA0164 ECHO16 TDA200 4 TDA100 2 16-port Echo Cancelling card NO CPU KX-TDA0166 Not in AL version

37 OPB-3 Card DPH2 DPH4 MSG4 CPU Flash Memory SRAM Extended I/O DSP
(rear) DPH2 DPH4 MSG4 ASIC

38 Digital Telephones Accessories T7636 T7633 T7630 T7625 4-Position Tilt

39 T7636 6-line x 24-character display Backlight 24 Programmable keys
Dual-colour LEDs Navigator Key Full duplex handsfree DXDP (version 1.1) Headset Jack 20-character extension ID Optional USB port Optional 12-CO keys

40 DXDP (Available Ver 1.1) * 0.5mm cable DPT DPT SLT Up to 720m*

41 T7633 3-line x 24-character display Backlight 24 Programmable keys
Dual-colour LEDs Navigator Key Full duplex handsfree DXDP (version 1.1) Headset Jack 20-character extension ID Optional USB port Optional 12-CO keys

42 T7630 3-line x 24-character display 24 Programmable keys
Dual-colour LEDs Navigator Key Full duplex handsfree DXDP (version 1.1) Headset Jack 20-character extension ID

43 T7625 24 Programmable keys Dual-colour LEDs Volume Key
Full duplex handsfree DXDP (version 1.1) Headset Jack

44 T7640 DSS 60 DSS/BLF keys Fully-programmable flexible keys
For all T76xx models Requires 1 digital port

45 T7603 Add-on Module 12 Programmable keys Dual-colour LEDs
Connects to DPT No additional port required For T7636 & T7633 only

46 T7590 DECT PS 4L x 16C Display 3 Programmable CO keys Tri-colour LED
Caller ID Ringer 6 tone, 4 melody + vibrate 100 number directory

47 Incoming Call Distribution SMDR(Call Information data)
System Resources Resource TDA100 TDA200 Tenant 8 8 COS 64 64 Trunk Group 64 64 Paging Group 32 32 Call Pick up Group 64 64 Incoming Call Distribution Group 64 (32Extn) 64 (32Extn) Idle Hunting Group 64 (16Extn) 64 (16Extn) VM(DPT) Group 2 2 VM(DTMF) Group 2 2 Queuing Time Table 64 64 Absent Message 9 9 Message Waiting 256 256 No. chars of the name 20 20 Extension Digits 1- 4 1- 4 Call Park Area 100 100 SMDR(Call Information data) 200 200

48 System Resources Conference Verified Code Special Carrier Code
TDA100 TDA200 Conference 10x3p – 4x8p (32CNFT) 10x3p – 4x8p (32CNFT) Verified Code 10 digits, 1000 entries 10 digits, 1000 entries Special Carrier Code 16 digits, 20 entries 16 digits, 20 entries Host PBX Access Code 10 digits, 4 entries/TG 10 digits, 4 entries/TG DDI/DID Table 16 digits, 1000 entries 16 digits, 1000 entries

49 System Resources Emergency Dial Quick Dial System Speed Dial
TDA100 TDA200 Emergency Dial 32 digits, 10 entries 32 digits, 10 entries Quick Dial 1-4 digits, 80 entries 1-4 digits, 80 entries System Speed Dial 32 digits, 1000 entries 32 digits, 1000 entries Station Speed Dial 32 digits, 10 ent./Ext 32 digits, 10 ent./Ext One Touch Dial 32 digits 32 digits Pick up Dial 32 digits 32 digits Key Pad protocol Dial 32 digits 32 digits Redial 32 digits 32 digits

50 System Resources Routing Plan Leading Digits Exception Leading Digits
TDA100 TDA200 Routing Plan 16 16 Leading Digits 10 digits, 1000 entries 10 digits, 1000 entries Exception Leading Digits 200 entries 200 entries ARS/LCR Carrier 10 10 Itemized Code 5 digits 5 digits Authorization Code 20 digits 20 digits TIE Routing Table 32 entries 32 entries Leading Digits 3 digits 3 digits PBX Code 7 digits 7 digits Toll Restriction Level 7 7 Toll restriction Code 7 digits, 100 entries/LV 7 digits, 100 entries/LV Toll restriction Exception Code 16 digits, 200 entries 16 digits, 200 entries

51 2 System Resources Charge Rate Charge Currency Charge Record for Hotel
TDA100 TDA200 Charge Rate 8 digits 8 digits Charge Currency 3 chars 3 chars Charge Record for Hotel 1000 2000 Call Log-Outgoing Call 0-100 log/EXTN MAX. 640 log/Sys 0-100 log/EXTN MAX. 640 log/Sys Call Log-Incoming Call 0-100 log/EXTN MAX log/Sys 0-100 log/EXTN MAX log/Sys Call Log-Incoming Call - ICD Group 0-100 log/EXTN MAX. 640 log/Sys 0-100 log/EXTN MAX. 640 log/Sys VPS(DPT) No. of Systems 2 systems 2 systems VPS(DPT) Number of Channels 24 CH 24 CH Mail BOX No.Digits 16 digits 16 digits System Password (Administrator) 4-10 digits 4-10 digits System Password (End user) 4-10 digits 4-10 digits Manager Password 4-10 digits 4-10 digits Extension PIN 0-10 digits/Station 0-10 digits/Station 2

52 Features 3

53 Installation 4

54 Installation Requirements
Dedicated 240VAC Power Source Static-Preventive procedures Category 3 Cabling (minimum Requirement) Avoid RF Interference (as much as possible) Avoid HF Interference (as much as possible) PC with TDA Maintenance s/w installed SD Card Reader/Writer (highly recommended)

55 Main Unit Installation
Wall Mounting

56 Main Unit Installation
Floor Mounting (TDA200 only)

57 Main Unit Installation
Minimum Clearances 10cm to left & right 20cm above Do not place objects on top of the Main Unit 20cm 10cm

58 Main Unit Construction

59 Power Supplies

60 RMT Card Installation MPR Card

61 CID/Paytone Card Installation
ELCOT16 Card

62 E1 Card Installation Trunk or Extension

63 BRI Card Installation Trunk or Extension

64 PRI Card Installation Trunk or Extension

65 Option Card Installation

66 Option Card Installation

67 DECT Installation CSIF8 Card Cabling Refer to Handout 5

68 Start-up Precautions 6 SD Card MUST be installed.
Begin with power ‘disconnected’, not just switched off. Discharge static before touching anything on the system. See Getting Started Guide 6

69 Programming

70 Programming 7 Windows-based Maintenance Console Structured Menu system
Multi-connection RS232c/USB/Modem/LAN/ISDN Remote SD Card Backup feature Diagnostics BRI Auto-configuration 7

71 Connection LAN Connection via CTI Link Card
Modem Connection via RMT Card External Modem Connection ISDN Modem Connection

72 PC Programming Software

73 Troubleshooting & Diagnostics

74 Troubleshooting & Diagnostics
Built-in Diagnostics Initial self-diagnostic test Various on-line diagnostic tests Background Manual Regular Digital Line Error Rate monitor

75 Troubleshooting & Diagnostics
Self-diagnosis Hardware is tested for each individual card at start-up. Error indication is shown on the card LEDs. Errors are recorded in the system log.

76 Troubleshooting & Diagnostics
On-line Diagnostics Periodical ‘active’ tests. Hardware Interrupt monitoring Reporting by: System Alarm LED Card Status LED Error Log Local Alarm Remote Alarm

77 Troubleshooting & Diagnostics
LED1 : Battery Alarm LED2 : SD card access MPU Card

78 Troubleshooting & Diagnostics
Option Cards LED1 OFF G ON G Flash R ON R Flash : Power OFF : Normal (all idle) : Normal (in use) : Fault / Reset : Out of Service

79 Troubleshooting & Diagnostics
Local Alarm On-site notification Alarm button programmed on DPT Remote Alarm PC Console / PC Phone Local Alarm creates message

80 Troubleshooting & Diagnostics

81 Troubleshooting & Diagnostics
Internet System PC Console or PC Phone DPT SMTP Server Customer Site Dealer Site

82 Thank You


Download ppt "Hybrid IP PBX."

Similar presentations


Ads by Google