Presentation is loading. Please wait.

Presentation is loading. Please wait.

Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd.

Similar presentations


Presentation on theme: "Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd."— Presentation transcript:

1 Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd

2 SUPREME HDPE Sprinkler Pipes and Fittings

3 Supreme Sprinkler………. Sprinkler system is a system where you can spray water through nozzles, at rate which is less than absorption capacity of soil. This system and it joints consists of pipes and fittings made up of HDPE. Water use can be optimized to get maximum benefits out of it, by means of this system. Supreme HDPE pipes and fittings accessories are designed and developed by experts, to provide you the best quality. SUPREME HDPE pipes and fittings are useful for all kinds of soils. It is useful where land is not leveled. By applying water through the sprinkler system, water can be saved,soil erosion can be prevented / reduced, temperature of plant area can be maintained in summer. All the plants get uniform and regular water, so plant growth is uniform and fast. The crop gets ready earlier compared to others. Quality of crop remains uniform, and production is more. Thus you get better income and reduced cost. Application : Suitable for almost all field crops like Wheat, Gram, Pulses as well as Vegetables, Cotton, Soya bean, Tea, Coffee, and other fodder crops. Suitable for Residential, Industrial, Hotel, Resorts, Public & Government Enterprises, Golf Links, Race courses. Salient Features : Portable, Chemically inert, Easy Handling, Quick installation, Corrosion resistant, Flexible and tough, Low labour, Protection from ultra violet rays.

4

5 DATA SHEET for Sprinkler Irrigation System: A. Raw Material RequirementReference Designation (MRS) 6.3, 8.0 & 10 Mpa at 20 º C IS;14151(pt-1); 1999 Melt Flow Rate (I 5 ) 0.2 to 1.10 Gm/10 min. at 190 º C IS;14151(pt-1); 1999 Density 940.4 to 958.4 Kg/cm 3 IS;14151(pt-1); 1999 B.Dimension As per tableIS;14151(pt-1); 1999 Length3.0 to 6.0m or as agreed between manufacturer and Purchaser. IS 14151 (pt-1): 1999 Visual Appearance (Surface Finish) SatisfactoryIS 14151 (pt-1): 1999 C. Performance Requirement Heat Reversion TestMax 3%IS 14151 (pt-1): 1999 Hydrostatic Pressure Resistance Test QUALITY TESTIS 14151 (pt-1): 1999 Duration: 165 hrs. at 80 º C, Stress Values : 3.5 Mpa ACCEPTANCE TEST Duration : 48 hrs at 80 º C,Stress Values: 3.8 Mpa Fusion Compatibility TestQUALITY TESTIS 14151 (pt-1): 1999 Duration: 165 hrs at 80 º C, Stress Values : 3.5 Mpa ACCEPTANCE TEST Duration : 48 hrs 80 º C, Stress Values : 3.8 Mpa Melt Flow Rate (I 5 )0.2 to 1.10 (both inclusive) Gm/10 min.IS 2530 : 1963

6 DATA SHEET for Sprinkler Irrigation System: Carbon Black Content & Dispersion2.5 ± 0.5%IS 2530 : 1963 Tensile Test19 Mpa(T/S) 500%(Elongation)IS 14151 (pt-1): 1999 Workmanship and AppearanceSatisfactoryIS 14151 (pt-2): 1999 Bearing Capacity of Holding AttachmentThe holding attachment is strong enough to withstand the pressure two times the working pressure of pipe. IS 14151 (pt-2): 1999 Leakage Testwithout leakageIS 14151 (pt-2): 1999 Hydraulic Proof TestThe assembly shall not show any sign of localized swelling, leakage, weeping or deformation and shall not burst during the test. IS 14151 (pt-2): 1999 Weldability TestQUALITY TESTIS 14151 (pt-2): 1999 Duration: 165 hrs. at 80 º C Stress Values : 3.5Mpa ACCEPTANCE TEST Duration : 48 hrs at 80 º C Stress Values: 3.8 Mpa D.Identification & MarkingColour: Black. All pipes shall be indelibly marked by hot foil embossing as per Colour code IS 14151: 1999 Class-1-----Orange Class-2------Red Class-3------Blue Class-4-------Green

7 Supreme Sprinkler pipes comply to IS 14151-Part I & Part II, Class 1( 0.25 Mpa ) - IS 14151 : 1999 Sr. No. OD(mm)Avg(mm).Thickness(mm)Avg(mm). MinMaxODMinMaxThickness 175.0075.7075.352.002.402.20 290.0090.8090.402.202.602.40 3110.00111.00110.502.703.202.95 4125.00126.20125.603.103.603.35 5140.00141.30140.653.504.103.80 6160.00161.50160.753.904.504.20 7180.00181.70180.854.405.004.70 8200.00201.80200.904.905.605.25

8 Supreme Sprinkler pipes comply to IS 14151 Part I & Part II : Class 2( 0.32 Mpa ) - IS 14151 : 1999 Sr. No. OD(mm)Avg(mm).Thickness(mm)Avg(mm). MinMaxODMinMaxThickness 163.0063.6063.302.002.402.20 275.0075.7075.352.502.902.70 390.0090.8090.402.903.403.15 4110.00111.00110.503.403.903.65 5125.00126.20125.603.804.504.15 6140.00141.30140.654.305.004.65 7160.00161.50160.754.905.605.25 8180.00181.70180.855.506.305.90 9200.00201.80200.906.107.006.55

9 Supreme Sprinkler pipes comply to IS 14151 Part I & Part II Class 3( 0.4 Mpa ) - IS 14151 : 1999 Sr. No. OD(mm)Avg(mm).Thickness(mm)Avg(mm). MinMaxODMinMaxThickness 150.0050.5050.252.002.402.20 263.0063.6063.302.502.902.70 375.0075.7075.353.003.403.20 490.0090.8090.403.504.103.80 5110.00111.00110.504.204.804.50 6125.00126.20125.604.805.505.15 7140.00141.30140.655.406.105.75 8160.00161.50160.756.207.006.60 9180.00181.70180.856.907.807.35 10200.00201.80200.907.708.708.20

10 Supreme Sprinkler pipes comply to IS 14151 Part I & Part II Class 4( 0.6 Mpa ) - IS 14151 (Part 1) : 1999 Sr. No. OD(mm)Avg(mm).Thickness(mm)Avg(mm). MinMaxODMinMaxThickness 140.0040.4040.202.302.802.55 250.0050.5050.252.903.403.15 363.0063.6063.303.804.404.10 475.0075.7075.354.505.204.85 590.0090.8090.405.306.105.70 6110.00111.00110.506.507.406.95 7125.00126.20125.607.408.307.85 8140.00141.30140.658.309.308.80 9160.00161.50160.759.4010.6010.00 10180.00181.70180.8510.6011.9011.25 11200.00201.80200.9011.8013.2012.50

11 Sprinkler Piping System Layout Design

12 THANK YOU……….. The Supreme Industries Limited


Download ppt "Supreme Sprinkler Pipes & Fittings Presentation The Supreme Industries Ltd."