Presentation is loading. Please wait.

Presentation is loading. Please wait.

Kitchen Ventilation.

Similar presentations


Presentation on theme: "Kitchen Ventilation."— Presentation transcript:

1 Kitchen Ventilation

2 Systems

3 Multi Point Ventilation

4 Heat Recovery Ventilator

5 Bath Ventilation

6 Bathroom Exhaust Fans

7 Bathroom Exhaust Fans CODE for Baths without bathing or spas:
3 SF Glazing ½ Operable or Baths 75SF or less - 50 CFM Fan or Over 75 SF – Intermittent Ventilation System 1 air change every 12 minutes Continuous Ventilation System at 20 CFM

8 Bathroom Exhaust Fans Baths with bathing and spas 50 CFM Intermittent
or 20 CFM Continuous

9 Multi Point Ventilation

10 Kitchen Ventilation Considerations
Fan Type Propeller Fan – Limited air capacity and noisy Axial Fan – Better air movement but still noisy Centrifugal Blower (Squirrel Cage) The best

11 Axial Fan

12 Centrifugal Blower

13 Sound Levels Sound is measured in Sones
1-Sone equals the loudness of a pure tone having a frequency of 1,000 hertz at 40 decibels.

14 Decibels 0 The softest sound a person can hear with normal hearing
10 normal breathing 20 whispering at 5 feet 30 soft whisper 50 rainfall 60 normal conversation 110 shouting in ear 120 thunder

15 Sones The Home Ventilation Institute sets a limit of 9.0 sones for kitchen fans up to 500 CFM Reference – A fan with a sone rating of 8.0 sones is twice as loud as one rated at 4.0 sones. Reference - Refrigerators run at about 1.0 sone.

16

17 Broan Silent Series 110 cfm .7 Sones

18 In-Line Ventilator Fan 110 CFM 1.0 Sones 210 CFM 2.0 Sones

19 Kitchen Ventilation

20 Kitchen Exhaust Fans CODE 100 CFM Intermittent Or 25 CFM Continuous

21 Multi Point Ventilation

22 Vented Hood System

23 Recirculating Fan in Microwave Combo

24 Kitchen Ventilation Heat Grease Steam Odor Smoke

25 Recirculating Range Hood

26 Recirculating Ventilation System
This type of system will only remove two Heat Steam

27 Downdraft

28 Down Draft Ventilation

29 Down Draft Ventilation

30 Range Hood Installation

31

32

33

34

35

36

37

38

39

40 Integral Fan Vented Through Roof

41 In Line Fan

42 Integral Through Soffit

43 Remote Ventilator

44 Through Crawlspace

45 Down Draft Through Floor

46 Down Draft Through Roof

47 Kitchen Ventilation Considerations
Fan – 250 CFM minimum Ducts Duct run lengths Interior Fan (power) Keep duct runs as short and straight as possible. 6” round or 3 ¼” x 10 rectangular ducts Maximum run = 25’ maximum

48 Kitchen Ventilation Considerations
Exterior or In-Line Fan (power) 9” round or 3 ¼” x 14” rectangular duct Maximum run = 55’ maximum