1 GROUP 4 Mikko Kaarakainen, Finland VAMK
Rene Paju Finland Metropolia UAS Alexandra Ciocoiu, Romania Vasile Alecsandri Keith Raekelboom, Belgium UA Lukas Lazar, Germany HS Bremen Iasonas Vovos, Greece UP

2 PROJECT VILLA

3 BUILDING Construction facts Usage Office building 12 employees
250 Working days / year Construction date Stone walls Wooden doors Wooden frames in roof, doors and windows (30 cm concrete rings on top of the walls) (concrete planes beneath the floor)

4 Lighting and other electricity
Current situation HEATING Lighting and other electricity COOLING Lightning is mixture of 60W incandescent lamps and 23W CFLs Server computers Computers Radiators Diesel boiler Electrical hot water boiler No mechanical ventilation Chiller

5 CLIMATE

6 Simulation of villa Design Insert the data Existing energy consumption

7 Results: Cooling Heating

8 Energy consumption Current situation Lightning: 5800 kWh
Computers: kWh Servers, UPS, switches: (running through the year) kWh Cooling: 8560 kWh Heating: 6070 kWh Total: kWh

9 Heating and Cooling

10 Constructional Improvements
Windows: Current windows  U value of 4,8 Improve  use of silicone or a film Or replace with double glazing Expensive! But U value of 2,0 Insulation Common U value in Greece = 0,7 Thickness: approximately 10 cm Rockwool Passive Ventilation: Chimney Effect

11 Electrical Improvements
Install consumption meters for measuring energy consumption New LED lamps Daylight controlled intelligent lightning system (DALI)

12 Intelligent lightning system

13 Energy consumption after improvements
Tighter windows, insulated roof, new lamps, lightning control system Lightning (7 W LED): 832 kWh Computers: kWh Servers, UPS, switches: kWh Cooling: 7240 kWh Heating: 4400 kWh Total: kWh

14 Annual savings With insulations and lightning improvements
Saved energy (0,15 €/kWh) In heating ΔE = 1670 kWh -> 250 € In cooling ΔE = 1320 kWh -> 200 € In lightning ΔE = 4970 kWh -> 750 € Using mechanical ventilation ΔE = 660 kWh -> 100 € Total savings: 8600 kWh -> 1300 €

15 Improved Heating and Cooling System

16 What to improve Selling the Diesel heater New pump for heating cycle
New UV-opaque insulation outside Renew pipe insulation Install PV on the campus

17 HOUSE 1 New roof/fix it New plaster
 white plaster to reflect light/radiation No insulation  thick walls PV panels on the roof south orientation possible Caps above the windows and doors New doors New windows New water pipes Connect electricity

18 HOUSE 2 Plaster on the outside walls Renovation of the balcony:
New plaster New paint New door

19 HOUSE 3 Best shaped building Only some slight changes:
New paint surface etc

20 THANKS FOR YOUR TIME!