Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 SAFECOM & HTC Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT.

Similar presentations


Presentation on theme: "1 SAFECOM & HTC Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT."— Presentation transcript:

1 1 SAFECOM & HTC Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT 8,415,822 US PATENT 5,747,888

2 2 Hulda transformers Company Profile:  Established in 1975 and is owned by Kibbutz Hulda.  A part of (KIA) the Kibbutz Industries Association represents over 300 factories & Companies owned by the kibbutz association in Israel.  It total KIA has 35,000 employees & over 8 billions US$ sales/year.

3 3 Main Markets:  Military & Aviation transformers.  Medical equipment manufacture.  Cable TV industry. Safety standard: CE, BABT, IEC, VDE & UL Quality Assurance Management System: ISO 9001:2008 certified. Hulda transformers Company

4 4 Mr David Zilberberg Privet company Hulda transformers Company Kibbutz Industries Association (KIA) Kibbutz Organization CATV Upstream noise blocker (UNB) CATV Patented Powering Kibbutz Hulda

5 Safecom's proven, patented SYNERGY-2, DPSV4, Power Booster & Dual T- former P.S turns CATV Optical & HTC networks into a super power synergy platform that provide most reliable and economic powering system for unlimited backup time. Safecom Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries DPS v5 Power Booster 4G SYNERGY-2 Dual T-former 2X 15A 60,66,72,87 V + DOCSIS Monitoring 5 Dual outputs T-former 15A (Indoor -Europe Standard ) 60,66,72,87 V

6 Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the SYNERGY-2 & DPS4 draws power from the distant available source over existing coax or power cables. Utilizing breakthrough direct AC/AC On-Line stabilize technology safecom's SYNERGY-2 and Power Booster ensures an optimal voltage level – even over long distances. The Backup Power concept. 6 Unlimited backup Power for CATV networks & Without Batteries (60V & 90 V standard)

7 Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the DPSv5 draws power from the distance available source over existing coax or power cables. Safecom's proven smart grid technologies greatly improve network powering reliability while creating significant savings in both capital and operational expenses. 1 2 3 4 Power + Signal To remote / Node / Amplifier Optical Node/Trunk amp P.S 2 1 3 4 AC 1 input. AC 2 input Local output to local Optical Node. (AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) US PATENT 5747888 EP 0708559 7 Power Booster Port Monitoring Port: voltage, RF PASS 5-1000 MHZ AC 1 Local Remote Current, status AC 2 Unlimited backup Power for Optical & HFC networks Without Batteries

8  MINIMIZE THE NUMBER OF POWER SUPPLIES IN THE NETWORK.  INCREASING THE POWERING AREA COVERED BY POWER SUPPLY Vin 30-87Vac (US) Vin 30-64Vac (EU ) t v t v Vout 87 Vac (US) Vout 60 Vac (EU) US PATENT 8,415,822 Utilizing patented breakthrough direct on-line zero crossing AC/AC stabilize technology safecom's ensures an optimal voltage level to Optical Nodes & Line Amplifiers even the source of power from over long distances. Passive, Standalone element, power booster solves the power distribution problem in a CATV network caused by high-resistance and low energy efficient coax & electricity cables. 8 RF PASS 5-1000 MHZ

9 Power Booster – the 4G Transmission 9

10 All in One two-way RF Pass 1GHZ passive device that “toggle” available Power between two distant locations. Redirecting power from the "normally" remote powered area to the area subject to power outage. During the normal mode of operation, when there is no power outage at either end of the pair, the SYNERGY-2 act as power block to the other side. Utilizing breakthrough step-up & stabilizing voltage technology the unit provides optimal & stable voltage level from local or remote P.S even from very long distance or using a un-stabilized P.S. = DPS V 4 Power Booster US PATENT 8,415,822 AC 1 input. AC 2 input Local output to local Optical Node. (AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) 1 2 3 4 Power + Signal To remote / Node / Amplifie r Optical Node/Trunk amp P.S 21 34 + 10 Unlimited backup Power for Optical & HFC networks Without Batteries

11 Inputs/ Output configuration Monitoring Inputs/outputs ONLINE Current & Voltage + status. AC 2 - InputAC1 - Input RF / AC 5-1000MHz 15A OUTPUT To Local Amplifier / Node RF / AC 5-1000Mhz 15A INPUT / OUTPUT To / From Remote Amplifier / Node US PATENT 8,415,822 Vin 30-87V Vac (US) Vin 30-64V Vac (EU ) t v t v Vout 87 Vac (US) Vout 60 Vac (EU) Inside view: SYNERGY-2 60/87V -2x15A 11

12 SYNERGY 2 the New generation. 12 Unlimited backup Power for Optical & HFC networks Without Batteries

13 US PATENT 8,415,822 NEW UR – Ultra Range +/- 25% Vin a a a a a a 13 a

14 DOCSIS® & EuroDOCSIS Status Monitoring, Embedded Transponder. Direct RF connection to CATV network Output 2 60,66,72 15A Output 1 60,66,72 15A External Monitoring DPS, SYNERGY-2 & more Dual Port P.S model SC-D-TFPS-1800-E-O-M 2 ports X 15A 60,75,87Vac 50/60 Hz. Direct connection. Voltage testing points Current loop testing points (For Clamp meter) 14

15 NEW-Dual Port P.S model SC-D-TFPS-1800-EOM 2 ports X 15A 60,75,87Vac 50/60 Hz. 15

16 Direct RF connection to CATV network Output 2 60,66,72 15A External Monitoring DPS, SYNERGY-2 & more NEW -Dual Port P.S model SC-D-TFPS-1800-UOM 2 ports X 15A 60,75,87Vac 50/60 Hz. Direct connection. Output 1 60,66,72 15A Direct connection. Voltage testing points Current testing points 16 Secondary AC input / Generator Main AC input Phase changer 120 KA SURGE SUPPRESSION DOCSIS® & EuroDOCSIS Status Monitoring, Embedded Transponder.

17 17 CATV Dual Port P.S 1350VA 15A 60,72,87V Model SC-STFPS-1350-90EI For hanging or shelf-lain mounting. NEW -Dual Port P.S model SC-D-TFPS-1350-90UI 2 ports, 15A 60,75,87Vac 50/60 Hz.

18 SYNERGY-2 Typical configuration Optical node + Trunk amplifier (or second optical node). Power + Signal From Optical node 4 21 3 1 2 3 4 AC 2 input. AC 2 input Local output to local Optical Node. (AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal Optical Node 21 34 To remote / amplifier / Node P.S. S P.S 60V Optical Node Or Trunk amplifier 60V Area A Area B 18 Unlimited backup Power for Optical & HFC networks Without Batteries

19 From Optical node 1 2 3 4 AC 2 input. AC 2 input Local output to local Optical Node. (AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal 21 34 To remote / amplifier / Node P.S. S P.S SYNERGY-2 – Demo backup power from Area A to Area B Power + Signal 60V 55V 50V 45V 60V Area A Area B 21 4 3 3 40V 60V 40V 19 60V Optical Node Or Trunk amplifier Optical Node Unlimited backup Power for Optical & HFC networks Without Batteries

20 Power + Signal To Optical node 4 21 3 1 2 3 4 AC 2 input. AC 2 input Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp) Power + Signal 21 34 From remote amplifier / Node P.S.S P.S 45V 50V 55V 60V SYNERGY-2 – Demo backup power from Area B to Area A P.S Area A Area B 40V 60V 20 Optical Node Or Trunk amplifier Optical Node Unlimited backup Power for Optical & HFC networks Without Batteries

21 SAFECOM’s powering system around the world. Reliability since 1994 21

22 22 Power backup Comparisons Synergy-2 / DPS V4 T-Former GeneratorsNon StandbyStandby + Batteries Power Type Low HighLowHigh Cost Zero PermanentNegligiblePermanent Maintenance Unlimited Limited by fuelNone 2 to 3 hour (Depends on batt. condition ) Backup Power Low cost Very expensiveLowVery Expensive Redundant/ Diversity Optional NON Integrated Surge Suppressor 120K Optional NON Integrated Phase Changer

23 Typical optical network powering examples 23

24 90V-network 60V-available 24 Deep Fiber Network 60V- SYNERGY backup power 60V-network 90V-available

25 60V-network 90V-available 25 HFC Network 90V- DPS5+ Power Booster backup power 90V-network 60V-available

26 Deep Fiber Network 90V- DPS5+ SYNERGY backup power 90V-network 60V-available 26

27 Business case. Improving customer service and satisfaction. Enabling MSO to add new services that required top high reliability. Unlimited backup time. Reducing dramatically CAPEX & OPEX. Increasing powering efficacy & save energy. 27

28 Complete Tree-View Import using CSV files Also can discover One node at a time from the UI (on –demand discovery) Network discovery Export the Tree-View for further Use 1.Discovery can be backed up 2.Automated Full Topology DPS/ SYNERGY back up Auto Discovery of the PS Monitor Supports any device that has an SCTE-HMS-PS-MIB Supports auto discovery of thresholds (SCTE-HMS-COMMON-MIB) Auto Generates Attribute Widgets with properly formatted thresholds Supports all Adjacent devices like APC, Cordex Controllers etc. Supports Discrete Thresholds DOCSIS® & EuroDOCSIS Status Monitoring 28

29 Monitors the Attributes – Pre-Configured Poll Interval – Summarization (Hourly, Daily) – Graphing (Single or Multiple attributes) – Attribute Refresh (on demand) Monitors the Current Alarm Table – Generates the Events from this table – Auto Correlation (If the alarm is pre-existing, does not generate a new Alarm) – Updates the Tree-view with corresponding Severity – If SNMP Traps are enabled, It will auto-correlate the incoming traps with Current Alarm table 29

30 Google Maps Integration 30

31 ON-LINE REPORT 31

32  Europe 60V & US 90V Standard.  Support full 15A rms input /output.  Prefect voltage at the remote location in the network.  †† Water-proof Enclosure. (IPX8)  Opposite connection protected.  †† Input & Output Surge Protection.  DOCSIS® & EuroDOCSIS Status Monitoring.  Online RF transmission during operation. (INTERNET, VOD, VOIP) DPSv4 / SYNERGY-2/ Power Booster    32 Standard Features

33 Summery SAFECOM SYNERGY-2 & DPSv5 & Power Booster offers CATV operators the most efficient and reliable complete backup solution for an unlimited time at minimum cost. No additional cost for MSO further to the fact that SYNERGY-2 / DPS v5 unit can be reused from HFC network to full optical network. Following the government regulation for full powering backup. SYNERGY-2, DPSv5 & Power Booster systems, enabling additional backup from remote powering. No maintenance. Unlimited lifetime. Two way powering on a single cable (Coax or electrical cable) Full DOCSIS® & EuroDOCSIS Status Monitoring 33

34 Thank you 34


Download ppt "1 SAFECOM & HTC Smart Powering Grid Patented technology, providing a complete set of unlimited backup Power for CATV networks & Without Batteries US PATENT."

Similar presentations