Presentation is loading. Please wait.

Presentation is loading. Please wait.

LOAD BANKS DIRECT The Load Bank of Choice www.LoadBanksDirect.com.

Similar presentations


Presentation on theme: "LOAD BANKS DIRECT The Load Bank of Choice www.LoadBanksDirect.com."— Presentation transcript:

1 LOAD BANKS DIRECT The Load Bank of Choice

2 LOAD BANKS DIRECT

3 Factory Direct Sales and Support  No Middleman Means Better Pricing and Service  Factory Person Answers Your Request, Every Time  Assembled Staff of Industry Experts  Each Member of Management Support Team Has 20+ Years Experience  No Miscommunication Between Customer to Rep to Factory  Privately Owned Means More Interest in Customers than Shareholders

4 LOAD BANKS DIRECT 100% Engineered and Manufactured in the USA

5 LOAD BANKS DIRECT Meets Rugged Industry Standards Comprehensive UL Listed Product Line

6 LOAD BANKS DIRECT Easily Movable Can be Transported to Different Locations Ideal for Service and Rental Companies or Customers in a “Campus” Setting Portable Load Banks

7 LOAD BANKS DIRECT Portable Load Banks Integral Control Panel For Simplified Operation Digital Power Metering Cam-Lok Power Connectors for Quick Connections Color Coded for ease of Phase identification High Capacity Light Weight Compact Designs Easily Transportable Robust Casters for Easy Transport

8 LOAD BANKS DIRECT LP150 Control and Blower Power 120 Volt AC, 1-phase A 15’ detachable line cord is provided Cam-Lok Quick-Connect-Disconnect Load Connectors Dimensions: 26.5"W x 33.5"D x 40"H Weight: 195 pounds DC and other Design Voltages Available 150 KW at 240 or 480 Volts AC, 3-Phase, 60 Hertz Also available in 480 VAC or 600 VAC designs

9 LOAD BANKS DIRECT LP200 Rated 200 KW at 400 Volts AC, 3-phase, 50 Hertz Blower Power 400 Volts AC, 3-phase, 50 Hertz Control circuits powered by integral 400:115 VAC 50 Hertz Control Power Transformer Cam-Lok Quick-Connect-Disconnect Load Connectors Dimensions: 26.5"W x 33.5"D x 48"H Weight: 275 pounds DC and other Design Voltages Available

10 LOAD BANKS DIRECT LP KW at 240 or 480 Volts AC, 3-Phase, 60 Hertz Also available in 480 VAC or 600 VAC designs Control and Blower Power 120 Volt AC, 1-phase A 15’ detachable line cord is provided Cam-Lok Quick-Connect-Disconnect Load Connectors Dimensions: 26.5"W x 33.5"D x 54"H Weight: 280 pounds DC and other Design Voltages Available

11 LOAD BANKS DIRECT Operator Controls Digital Power Meter: Measures 16 Load Parameters including 3-phase Volts, Amps, Frequency and Power Functions Includes RS485 (Modbus protocol) for Remote Reading Main Power On/Off, Blower Start/Stop, Master Load On/Off Switch, and Individual Load Step Switches Illuminated Indicators Provided for Main Power On, Blower On, Motor Overload, Airflow Failure, Over-Temperature, Wrong Voltage Applied and Load Dump Emergency-Stop (E-STOP) Push Button

12 LOAD BANKS DIRECT LP400 LP KW at 400, 240/480, 480 and 600 Volts AC 500 KW at 400, 240/480, 480 and 600 Volts AC Blower Power 5 HP 230/460 VAC 3-phase, 60 Hertz  7.5 HP for 400 VAC 50 Hertz Models  5 HP 575 VAC for 600 VAC 60 Hertz Models Control Power: External 120 Volt AC, 1-phase, or Powered by Integral Control Power Transformer Cam-Lok Quick-Connect-Disconnect Load Connectors Dimensions: 33.5"W x 48.5"D x 62.5"H Weight: 875 pounds DC and other Design Voltages Available

13 LOAD BANKS DIRECT LP800 LP1000 Dimensions: 33.5"W x 48.5"D x 76.5"H Weight: pounds DC and other Design Voltages Available Blower Power 10 HP at 460 VAC, 3-Phase 60 Hertz, or 10 HP at 400 VAC, 3-phase, 50 Hertz Control Power External 120 Volt AC, 1-phase, or Powered by Integral Control Power Transformer Cam-Lok Quick-Connect-Disconnect Load Connectors 800 KW at 400 Volts, 3-phase, 50 Hertz 1000 KW at 480 Volts, 3-phase, 60 Hertz

14 LOAD BANKS DIRECT LP800 and LP1000 Local Operator Controls, including: Main Power On/Off, Blower Start/Stop, Master Load On/Off Switch, and Individual Load Step Switches Illuminated Indicators Provided for Main Power On, Blower On, Motor Overload, Airflow Failure, Over-Temperature, and Load Dump Emergency-Stop (E-STOP) Push Button Digital Power Meter: Measures 16 Load Parameters including 3-phase Volts, Amps, Frequency and Power Functions Includes RS485 (Modbus protocol) for Remote Reading

15 LOAD BANKS DIRECT Stationary Load Banks Vertical Air Flow Safer for Personnel and Surrounding Equipment Isolated Control and Resistor Compartments Outdoor Duty NEMA 3R Design Reduces “Installed” Footprint

16 LOAD BANKS DIRECT 50 KW through 2500 KW

17 LOAD BANKS DIRECT LS KW at 208, 400, 240/480, and 600 VAC LS KW at 208, 400, 240/480, and 600 VAC LS KW at 208, 400, 240/480, and 600 VAC LS KW at 208, 400, 240/480, and 600 VAC LS KW at 208, 400, 240/480, and 600 VAC LS KW at 208, 400, 240/480, and 600 VAC Dimensions: 27"W x 31"D x 52"H Weight: pounds DC and other Design Voltages Available

18 LOAD BANKS DIRECT Galvanized Steel with Powder Coat Paint Finish and Stainless Steel Hardware Easy Front Access to Control Components Plated Copper Bus Bars Remote Operator Control Panel Heavy Duty Construction

19 LOAD BANKS DIRECT LS KW at 208, 400, 240/480, and 600 VAC LS KW at 208, 400, 240/480, and 600 VAC LS KW at 208, 400, 240/480, and 600 VAC LS KW at 208, 400, 240/480, and 600 VAC LS KW at 400, 240/480, and 600 VAC LS KW at 240/480, and 600 VAC LS KW at 240/480, and 600 VAC LS KW at 480, and 600 VAC Dimensions: 40.25"W x 52.5"D x 69"H Weight: pounds DC and other Design Voltages Available

20 LOAD BANKS DIRECT LS KW at 400, 480, and 600 Volts AC LS KW at 400, 480 and 600 Volts AC LS KW at 480 and 600 Volts AC LS KW at 480 and 600 Volts AC LS KW at 480 and 600 Volts AC Dimensions: 40.25"W x 52.5"D x 92"H Weight: pounds DC and other Design Voltages Available

21 LOAD BANKS DIRECT LS KW at 400, 480 and 600 Volts AC LS KW at 400, 480 and 600 Volts AC LS KW at 480 and 600 Volts AC LS KW at 480 and 600 Volts AC Dimensions: 40.25"W x 88"D x 92"H Weight: pounds DC and other Design Voltages Available

22 LOAD BANKS DIRECT Your Complete Solutions Provider Widest Range of Portable, Stationary, and Duct Mounted Designs Conservative Designs Enhanced Safety Circuits Smaller Footprints Lighter Weight BEST Customer Service and Support

23 LOAD BANKS DIRECT The Load Bank of Choice Toll Free 855-LBD-CALL ( ) Your Complete Solutions Provider


Download ppt "LOAD BANKS DIRECT The Load Bank of Choice www.LoadBanksDirect.com."