Presentation is loading. Please wait.

Presentation is loading. Please wait.

Intermec Solutions for Hazardous Environments: CK32IS.

Similar presentations


Presentation on theme: "Intermec Solutions for Hazardous Environments: CK32IS."— Presentation transcript:

1 Intermec Solutions for Hazardous Environments: CK32IS

2 Slide 2 UL (Underwriters Laboratory) ATEX (European Atmospheres Explosibles Directives) IEC (International Electrotechnical Commission) Global Considerations Global Certification requirements U.S. Canada Mexico European Union Norway Switzerland Turkey Australia Singapore Malaysia Philippines Indonesia Saudi Arabia Austria Belgium Bulgaria Cyprus Czech Republic Denmark Estonia Finland France Germany Greece Hungary Ireland Italy Latvia Lithuania Luxembourg Malta Netherlands Poland Portugal Romania Slovakia Slovenia Spain Sweden United Kingdom of Great Britain and Northern Ireland

3 Slide 3 Hazardous Environment Certifications UL, ATEX, IEC Localized Languages English, Spanish, French, German, Italian, Simplified Chinese, Traditional Chinese, Korean, Thai (character set only) RoHS Compliance Restriction of the Use of Certain Hazardous Substance in Electrical and Electronic Equipment WEEE Compliance Waste Electrical and Electronic Equipment RF Certifications Support & Service Certified repairs at all service centers worldwide Global Reach

4 Slide 4 UL (Underwriters Laboratory) ATEX (European Atmospheres Explosibles Directives) IEC (International Electrotechnical Commission) Hazardous Certifications Gases, Liquids, Vapors Class I Division 1 Group A,B,C,D (T4) Class 1 Zone 0 Group IIC (T4) Gases, Liquids, Vapors Zone 0 (T4) Group IIC Gases, Liquids, Vapors Zone 0 (T4) Group IIC Dusts & Fibers Class II Division 1 Groups E, F and G Dusts & Fibers Zone 20 Group II* T250°C Dusts & Fibers Zone 20 Group II* T250°C Underground Mining Group I M1 Underground Mining Group I M1 Class III Division 1 * Except conductive dust

5 Slide 5 UL (Underwriters Laboratory) ATEX (European Atmospheres Explosibles Directives) IEC (International Electrotechnical Commission) Hazardous Certifications * Except conductive dust From concept, design specifications dedicated to meeting customer’s most stringent requirements for flammable gases, vapors, liquids, dusts or fibers. Gases, Liquids, Vapors Class I Division 1 Group A,B,C,D (T4) Class 1 Zone 0 Group IIC (T4) Gases, Liquids, Vapors Zone 0 (T4) Group IIC Gases, Liquids, Vapors Zone 0 (T4) Group IIC Dusts & Fibers Class II Division 1 Groups E, F and G Dusts & Fibers Zone 20 Group II* T250°C Dusts & Fibers Zone 20 Group II* T250°C Underground Mining Group I M1 Underground Mining Group I M1 Class III Division 1

6 Slide 6 High Level Device Requirements Chemical, Oil & Gas, and Pharmaceutical customers told us their “ideal” requirements: One Device - Globally One Manufacturer - Globally Long Product Life Cycle Industry Commitment - Globally Global Technical Support & Service

7 Slide 7 Detailed Device Requirements – Typical Customer Device: Windows mobile PDA Hazardous Ratings: 60% - UL Class 1 Div 2 for North America 5% - UL Class 1 Div 1 for North America 20% - ATEX Zone 2 for Europe 5% - ATEX Zone 1 for Europe 10% - IEC, Rest of World (RoW) Memory: 128 MB of RAM / 512 MB of Flash Storage Communications: 802.11b/g Cisco CCX V3 radio support Bluetooth – Used to talk to peripherals (RFID, Vibration, Temperature probes) Keyboard/Ergonomics: Big, easy to use Arrows & Numeric Keys (for use in gloved environments) User installable Trigger Handle Support: 8 Hours of Battery Life No loss of data/application after cold boot Global Support Lock Down Application

8 Slide 8 Detailed Device Requirements – What are yours? Device? Hazardous Ratings? Memory? Communications? Keyboard/Ergonomics? Support?

9 Slide 9 Enterprise Asset Management Solutions Example: Plant Maintenance & Repair Trend Good maintenance and support practices are an integral component of optimized production processes and lean manufacturing. Key Issues Manufacturers are focused on improving the efficiency of production. As production capacity rises above 80% utilization, efficiency and productivity in plant maintenance and repair is mandatory. Return on Assets (ROA) is becoming the primary driver of equipment investment. Solutions In-premise and extra-premise predictive maintenance. Break-Fix operations. Dispatching for optimized production. Operator directed response (ODR).

10 Slide 10 Intermec Hazardous Environment Solutions 751 Class I Div 2751 ATEX Zone 2730 Class I Div 1 CK31 Class I Div 2 CK61 Class I Div 2 CK32IS

11 Slide 11 Intermec Hazardous Environment Solutions 751 Class 1 Div 2751 ATEX Zone 2730 Class 1 Div 1 CK31 Class 1 Div 2 CK61 Class1 Div 2 CK32IS Mobile Computers Fixed Mount Computers RFID ScannersPrinters Intermec Solutions Family

12 CK32 Intrinsically Safe Mobile Computer

13 Slide 13 CK32IS Features Intermec Linear Imager 42 or 56 Keypad options (Standard, 3270/5250, VT/ANSI) 128 MB RAM 512 MB Persistent Storage QVGA Color Display w/ Touchscreen Intel XScale PXA270 Processor 802.11b/g WLAN w/ CCX 3, USB Bluetooth & Ethernet Windows Mobile 5.0 Premium & Phone Edition & MSFP Integrated Speaker/microphone

14 Slide 14 CK32IS Usability User installable trigger handle Batteries removable in hazardous environments Keypad options support gloved use

15 Slide 15 CK32IS Accessories * Associated Apparatus Certified – Guarantees that any outside equipment cannot damage the unit. Not for use in Hazardous environments. Communication Adapter* USB Client and Ethernet Battery Eliminator Battery Pack Option Quad Battery Charger* Trigger Handle User Installable Carrying Strap Leather Hand Strap Screen Protector Kit Tethered Stylus Kit

16 Slide 16 CK32IS Durability Electrostatic Dissipation Internal Antennas Hard Plastic Key tops Polycarbonate Enclosure Internal Magnesium Frame Internal Shock Mounting Encapsulated Circuit Boards Designed from inception for exceptional durability 5 foot drop specification IP67 sealed Operating temperature: -20°C to +50°C Robust construction:

17 Slide 17 Hardware Durability Internal Magnesium Frame Thicker than comparable frame in standard product Lightweight but strong Internal skeleton

18 Slide 18 Hardware Durability Magnesium frame Reduces flexing, risk of damage Maintains relative alignment and spacing Protects LCD display glass

19 Slide 19 Hardware Durability Encapsulated Circuit Boards High temperature silicon for thermal insulation Second line of protection against gas & dust Protects components from shock, vibration, corrosion

20 Slide 20 Hardware Durability Internal Shock Mounting Isolates electronic modules Display

21 Slide 21 Hardware Durability Hard Plastic Key Caps Laser engraved Silicon Keypad Touch Screen Touch Screen Protector

22 Slide 22 Hardware Durability Polycarbonate Enclosure Extra thick, high quality, reinforced Conductive IP67-rated seal Modular construction

23 Slide 23 Worldwide Service & Support Medallion service contracts Tel and web based post sales support More than 70 service & support facilities Local languages, time zones Intermec Repair Locations Intermec Global Service Partners

24 Slide 24 UL (Underwriters Laboratory) ATEX (European Atmospheres Explosibles Directives) IEC (International Electrotechnical Commission) CK32IS Hazardous Certifications Certified Intrinsically Safe by ALL 3 global agencies, for gases, vapors, liquids, dusts, fibers and underground mining. Today’s safety requirements. And tomorrow’s. * Except conductive dust Gases, Liquids, Vapors Class I Division 1 Group A,B,C,D (T4) Class 1 Zone 0 Group IIC (T4) Gases, Liquids, Vapors Zone 0 (T4) Group IIC Gases, Liquids, Vapors Zone 0 (T4) Group IIC Dusts & Fibers Class II Division 1 Groups E, F and G Dusts & Fibers Zone 20 Group II* T250°C Dusts & Fibers Zone 20 Group II* T250°C Underground Mining Group I M1 Underground Mining Group I M1 Class III Division 1

25 Slide 25 Designed to Deliver Highest Level of Safety Full International Safety Certifications in One Computer Meets or Exceeds Latest Safety Standards: Zone 0 Exceptionally Rugged: 5’ drop, IP67 Worldwide Service & Support

26 Slide 26 Next Steps Compliance: Define your safety certification requirements Configuration: Determine detailed device requirements Service & Support: Determine global needs

27 Slide 27 Thank you! ADC NordicADC Nordic - Distributor in the Nordic countries Phone +46 40-680 02 80