1 2007. 03. 07 H/W Team R&D Center / BCS Dept. Installation of

2 1/17 BKSU Unpacking Tie cableAnchor plug Screw Fuse CD manual Power cord Battery cable

3 2/17 EKSU Unpacking Tie cable Anchor plug Screw Fuse Power cord Battery cable Link cable

4 3/17 Rack / Wall Mountable Expandable Structure Compact Cabinet Size 339 x 288 x 85 (mm) KSU Exterior and Dimension

5 4/17 Opening the Front Cover Open the Cord cover and turn the screws counter-clockwise to loosen as shown in Figure Lift the front cover in the direction of the arrow as shown

6 5/17 Before installation, assure that the AC plug is not connected to an AC outlet. The PSU is located at the left in the KSU and is pre-installed in the ipLDK-60 KSU. The PSU provides three DC voltage power sources to MBU through the 7-pin connector, CN7. Mains input: 100 ~230Vac Power Supply Unit Installation

7 6/17 Place the PSU cover on the PSU as shown in Figure. Then secure the PSU cover by tightening the screws (clockwise turn). Power Supply Unit Installation

8 7/17 Frame Ground Connection It is very important that the frame of the ipLDK-60 System is grounded: Turn the grounding screw counter clockwise to loosen, as shown in Figure. Insert the grounding wire and tighten the screw. Then connect the grounding wire to an appropriate ground source (refer to Caution). CAUTION The equipment should be connected to a socket-outlet with a protective ground connection. For ground wire, green-and-yellow insulation is required and the cross-sectional area of the conductor must be more than UL 1015 AWG#18 (1.0mm)). It is recommended that the ground wire is shorter than 1m (3.28ft). Proper grounding is very important to protect the ipLDK-60 from external noise or to reduce the risk of electrocution in the event of lightning strike. Be sure to comply with applicable local regulations.

9 8/17 The external batteries must provide 24V DC; this is generally accomplished by connecting two 12V batteries in a series arrangement as shown. External Backup Battery Installation NOTE The cable used to connect the battery is supplied with the KSU. CAUTION It is recommended to use an external backup battery fuse (5A @250V) between the battery and the System. Recommended battery capacity is 24V/20AH MF; Carefully check the battery polarity with cable colors Red(+) and Blue(-) when connecting the battery to the System. Make sure that you do not short out the external batteries and cables. There is a danger of explosion if external batteries are incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.

10 9/17 Expansion KSU to Basic KSU Connection Remove the dummy of each KSU. Use the link cable to connect the Basic KSU to the Expansion KSU. To fix the link cable securely, turn the screw clockwise to tighten and then tie the link cable with tie cable.

11 10/17 MBU Connection ports

12 11/17 MBU MJ1 (CO) MBU MJ1–1,2,3 Connector PIN NumberNOSignal Name RJ111,2N/A 3,4CO-T, CO-R 5,6N/A MBU MJ2 (Extension) MBU MJ2-1 (DKT ONLY) CONNECTORPIN NUMBERNOSIGNAL NAME RJ111N/A 2DKT-T 3,4ALARM_Detection 5DKT-R 6N/A MBU MJ2–2,3,4,5,6,7,8 CONNECTORPIN NUMBERNOSIGNAL NAME RJ111N/A 2DKT-T 3,4SLT-T, SLT-R 5DKT-R 6N/A NOTEWhen installing DKT or SLT on Hybrid Ports, (MJ2-2,3,4,5,6,7,8), keep the above pin assignment. Otherwise the DKT or SLT will not operate normally. MBU Connection ports

13 12/17 TERMINAL DKT CONNECTORPIN NUMBERNOSIGNAL NAME RJ111N/A 2RING 3,4Reserved 5TIP 6N/A TERMINAL SLT CONNECTORPIN NUMBERNOSIGNAL NAME RJ111,2N/A 3,4TIP, RING 5,6N/A MBU Connection ports

14 13/17 CN13 Pin Assignment (Relay Contact) CONNECTOR NOSIGNAL NAME 4 PIN 1Relay 1-pin1 2Relay 1-pin2 3Relay 2-pin1 4Relay 2-pin2 MJ3 Pin Assignment (LAN) ConnectorPin NumberNOSIGNAL NAMEFUNCTION RJ454,5,7,8RESERVED 1TX+Transmit Data 2TX-Transmit Data 3RX-Receive Data 6RX+Receive Data MBU Connection ports

15 14/17 Terminal Cabling Distance

16 15/17 The following illustrates how to connect the DKT to your System: Basic Terminal Connection ( DKT and DSS) PIN ASSIGNMENT CONNECTORPIN NUMBERNOSIGNAL NAME RJ111N/A 2RING 3,4Reserved 5TIP 6N/A 2 wire

17 16/17 The following illustrates how to connect the SLT to your System: Basic Terminal Connection ( SLT) CONNECTORPIN NUMBERNOSIGNAL NAME RJ111,2N/A 3,4TIP, RING 5,6N/A PIN ASSIGNMENT

18 17/17 The MBU provides connections one external music source PJ1 (RED, External MOH), one external page port PJ2 (BLUE, External Page) two relay contact, an alarm detection input monitor through the MJ2 Connecting Additional Terminals External relay contact