Presentation is loading. Please wait.

Presentation is loading. Please wait.

Aerobic and anaerobic biological wastewater treatment processes: Case studies

Similar presentations


Presentation on theme: "Aerobic and anaerobic biological wastewater treatment processes: Case studies"— Presentation transcript:

1

2 Aerobic and anaerobic biological wastewater treatment processes: Case studies
Presenting by: Ghasem D. Najafpour Coworkers: Zeinab Bakhshi Esmaeel Kariminezhad, Roya Pishgar Babol Noshirvani University of Technology February 2011

3 Environmental pollution Harmful to human & plants
Threat to aquatic life Major concern of mankind

4 Wastewater treatment processes
Biological Anaerobic Aerobic Physical Chemical

5 Aerobic Biological Processes
Organic matter serves as electron donor Oxygen serves as electron acceptor Remove colloidal and suspended solids Remove organic compounds to prevent excessive DO depletion Aerobic Biological Processes

6 Aerobic suspended growth processes
Microorganisms are preserved in liquid suspension by suitable mixing methods Adequate dissolved oxygen concentration is required Aerobic suspended growth processes One of the most important suspended growth technologies is activated sludge process Used for biological treatment of municipal and industrial wastewaters

7 Aerobic attached growth processes
Less energy consumption Simpler operation Better recovery after shock toxic loads Less equipment maintenance Better sludge thickening properties No bulking problems

8 Anaerobic Biological Processes
Biogas Residual organic matters Microbial biomass Organic matter

9 Advantages: Methane production Less Energy required
Less biological sludge produced Low nutrients required Methane production Small reactor volume

10 Biological Processes performed in this study
Aerobic Biological Processes Attached Growth RBC Suspended Growth Activated sludge

11 Rotating Biological Contactor (RBC)
Wastewater characteristic Dairy Wastewater Gela, Amol, iran Reactor Configuration Working Volume 65.6 Liter Length 75 cm Width 35 cm Depth 30 cm Total Discs number 48 Disc Diameter 16 cm

12 Reactor Performance Figure 1: COD removal efficiency with respect to OLR with and without recirculation

13 Activated Sludge Wastewater characteristic
Amol industrial park wastewater Mazandaran, Iran Figure 2: Schematic Figure of Amol Industrial Wastewater treatment plant

14 Activated Sludge

15 Figure 3: COD removal and effluent COD with respect to HRT
Figure 4: Effect of recycle ratio on COD removal, SVI and F/M

16 Figure 5: COD removal with respect to HRT
Wastewater characteristic Yasreb municipal wastewater plant Ghaemshahr, Iran Figure 5: COD removal with respect to HRT Figure 6: Effect of recycle ratio on COD removal, SVI and F/M

17 Biological Processes performed in this study
Anaerobic Biological Processes Attached Growth UASFF

18 UASFF Bioreactor Reactor Configuration Internal Diameter 2.76 cm
Height 160 cm Total Volume 960 ml Support material Seashell Void 85%

19 Dairy wastewater Characteristic
Value COD (mg/l) Lactose (g/l) 50-60 TS (g/l) 55-65 VS (g/l) 49 Proteins (g/l) 2.2 Phosphate (g/l) 0.6 Ca (g/l) 0.02 pH

20 Reactor operation Acclimation period 26 days COD concentration
mg/l Duration of each period 8 days Temperature 37 °C HRT 36 & 48 h

21 Figure 7: COD removal efficiency with respect to OLR for HRTs 36 and 48 h

22 UASFF Bioreactor Main characteristics of pulp and paper wastewater
Wastewater characteristic Pulp and paper wastewater Sari, Iran Main characteristics of pulp and paper wastewater Value Flow (m3/h) 984 pH 7-8 Temp (˚C) 37-55 SS (mg/l) 900 COD (mg/l) 2800 BOD5 (mg/l) 1140 Resin acids (mg/l) 140 Sulfur (mg/l) 150 UASFF Bioreactor

23 Figure 8: Schematic diagram of UASFF bioreactor

24 Figure 9: COD removal with respect to HRT at temperature 37 and 55 °C

25 Conclusions: Aerobic and anaerobic processes are capable of treating industrial and municipal wastewaters UASFF had a considerable performance on treatment of dairy and pulp and paper wastewaters Pulp and paper removal efficiency (HRT 24 h): 37 ˚C % 55 ˚C % Dairy Wastewater removal efficiency: HRT 36 h % HRT 48 h %

26 Treatment of Dairy wastewater by RBC:
Improvement of 10% in COD removal efficiency by changing the operation mode to with recirculation Activated sludge was able to treat municipal and industrial wastewaters significantly. Industrial wastewater: Recycle ratio: 0.85 COD removal Efficiency: 95% SVI: 83 F/M: 1.1 Municipal wastewater: Recycle ratio: 0.2 COD removal efficiency: 85% SVI: 100 F/M:0.3

27 Biotechnology Research Laboratory,
Babol Noshirvani University of Technology

28 Anaerobic baffled reactor Upflow anaerobic packed bed reactor
Wastewater treatment Group Anaerobic baffled reactor Upflow anaerobic packed bed reactor Group Members: Nafise Moosavi, Zeinab Bakhshi

29 Anaerobic Fluidized bed reactor
Wastewater treatment Group Anaerobic CSTR Anaerobic Fluidized bed reactor Group Members: Roya Pishgar, Tahere Taghizade

30 Adsorption & Chitosan production Group
Enzyme Group Group Members: Zahra Vaseghi, Maryam Hosseinpour, Samane Mohseni Adsorption & Chitosan production Group Group Members: Marjan Khorrami, Hamide Radnia

31 Microbial Fuel Cell Group
Group Members: Mostafa Rahimnezhad, Fahime Haghparast, Tahere Jafari

32 Thank you for your attention


Download ppt "Aerobic and anaerobic biological wastewater treatment processes: Case studies"

Similar presentations


Ads by Google