Presentation is loading. Please wait.

Presentation is loading. Please wait.

TECNIPLAST Marketing Corporate. The idea Library Style.

Similar presentations


Presentation on theme: "TECNIPLAST Marketing Corporate. The idea Library Style."— Presentation transcript:

1 TECNIPLAST Marketing Corporate

2 The idea Library Style

3 Mouse Library Plus (ML + ) Mouse Library Plus (ML + ) Motorized Mouse Library Plus (MML + ) MML Plus  The racks are moved by a motorized wheel on the rear side of AHU ML Plus  The racks are moved by the operators Railway guide

4 Features Increased Density Ergonomics Easy to Install and Maintain Silent, No Vibrations

5 Increased Density In the same room (depending on the room dimension and shape) it is possible to fit a higher number of racks compared to a standard configuration This because the Library System allows to move the racks in order to create enough room for caretakers or researchers

6 Increased Density / ML Plus up to 18% more density compared to a standard layout Standard configuration Room size 55.59 m 2 Density 25.18 c/m 2 Density 2.34 c/ft 2 ML Plus Room size 47.15 m 2 Density 29.69 c/m 2 Density 2.76 c/ft 2

7 Increased Density / MML Plus Standard configuration Room size 55.59 m 2 Density 25.18 c/m 2 Density 2.34 c/ft 2 MML Plus Room size 40.89 m 2 Density 34,23 c/m 2 Density 3.18 c/ft 2 The ML+ requires the operator to move the racks manually: to do so, there must be a minimum distance of 70 cm from the closest racks. As to MML+, the minimum distance between racks is 40 cm, but is required just to allow a proper light intensity and exposure time, because the racks are moved by pushing a button. up to 30% more density compared to a standard layout

8 Ergonomics MML Plus  The racks are moved simply by pushing a button No effort ML Plus  The racks can be easily moved by means of handles

9 Easy to Install and Maintain Two double sided racks and the AHU are linked by a quick release SS frame system that allows to position the AHU either: -between the two racks (mandatory for 2GM160 racks)  ACRACKML / ACRACKMML -at the racks’ side (next to the wall)  ACBOXML / ACBOXMML (in this case you also have to use an interlinking devices for rack to rack connection ACBOXLYGM03)

10 Easy to Install and Maintain Railway Guide Wall mounted (wall must withstand 1000 Nm Torque) Floor mounted The same for all the Library System (ML +, MML + and AML)

11 Silent, No Vibrations The racks can be moved without producing any noise The whole system is extremely stable, with no vibration when moving the racks No stress for the animals

12 AHU The dedicated Smart/Easy Flow features some modifications compared to standard one: A modified (SS straight vertical) supply pipe A modified (SS straight vertical) exhaust pipe Standard Smart/Easy Flow cannot be retrofitted. A modified exhaust collector

13 AHU The dedicated Smart/Easy Flow features some modifications compared to standard one: Anytime ML + can be upgraded to MML + thanks to a retrofit motorized wheel kit A motorized wheel on the rear side of AHU (just for MML Plus)

14 Racks Same as standard double-sided range of racks. Differences: 2 “0-90 degrees” lockable wheels for each rack  Retrofittable 2 wheels dedicated for library version  Retrofittable 4 handles (2 each side)  Retrofittable

15 Library Style: available Rack types ML+/ MML+ with AHU between two racks or at their sides DGM (10 levels)Available DGM (9 levels)RFQ required (AHU has to be customized) AERONot Available GR/DD/BLUE Line/Blue Line NEXT RFQ required

16 ML + / MML + / AML Minimun Requirements 1) The power supply, 2) The exhaust thimble connections (and eventually the 3) Automatic Watering System connections) on the ceiling have to be located in a position that allow the train movements. STAND-BY LEFT RIGHT spigot power cable Check the SIL!

17 The exhaust connections on the ceiling have to be located in a position that allow the train movements. A better solution (if possible) is the exhaust channel The Project Management has to be involved from the beginning as soon as possible “chimney” style Check the SIL! ML + / MML + / AML Minimun Requirements

18 Thank You !!! TECNIPLAST Marketing Corporate