Presentation is loading. Please wait.

Presentation is loading. Please wait.

New 230V boards for swing-leaf gate operators

Similar presentations


Presentation on theme: "New 230V boards for swing-leaf gate operators"— Presentation transcript:

1 New 230V boards for swing-leaf gate operators
1

2 Contents Why new 230V boards? Market positioning
A few words about the new 230V boards USPs 2

3 Why new 230V boards? E 145 E 045  SAFEzone: with the new boards for 230V operators (both hydraulic and electro-mechanical) , obstacle detection and reversal rapidity are always granted  safety condition in compliance with DM 2006/42/EC  GREEN TECH: solutions have been adopted to save power up to 90% compared to traditional systems  Connectivity: the new boards support BUS 2Easy; the E145 model, which can also be programmed from PC/MAC, is prepared for the connection to the new modules for GSM, Ethernet and WiFi. 3

4 Contents Why new 230V boards? Market positioning
A few words about the new 230V boards USPs 4

5 Performance Positioning Performance Phase Out E145 top of the range
Current range Phase Out New range E145 top of the range 462DF programmed using an external device (FAACtotum) 455D display, advanced controls E045 similar to 455D 452MPS entry level, dip switch and LED. 455D limited availability 5

6 Contents Why new 230V boards? Market positioning
A few words about the new 230V boards USPs 6

7 SAFEzone Both boards control the new SAFEcoder Absolute Encoder via the BUS 2Easy input. 7

8 SAFEzone Strong points of the SAFEcoder: It enables the reverse on contact feature It is directly fitted on the operator bracket (FAAC PATENT) Backward-compatible: it can be fitted on existing systems without having to modify any fittings or installation dimensions. It is able to find, automatically and with high accuracy, the deceleration and stop points, thus preventing the automated system from forcing against the stop point If the stop points are set by hand there is no mechanical stops need In the event of a power fault, the absolute encoder keeps the leaf position memorized, wherever it stopped, thus avoiding irregular cycles after special events. Therefore it fully complies with the new Machinery Directive 2006/42/EC 8

9 GREEN TECH Both boards have been designed to offer the highest energy efficiency (thanks to the switching power supply), resulting thus in a reduced current consumption and money saving. The E145 board is furthermore able to operate at very low consumption conditions (Sleep) during standby. Comparison between the top 230V boards of the 3 main competitors* Test conditions: control board for 230V motors in standby, 2 pairs of photocells, radio receiver * Competitor’s data are results of laboratory test 9

10 GREEN TECH EXAMPLE: Saving of a 230V automated system with 2 leaves equipped with the new FAAC boards, 2 BUS photocells and radio receiver with respect to a traditional automated system of A competitor. Energy efficiency in standby Hypotesis: Residential Energy Price = 0,20 €/KWh * E045 E145 Standby saving W saved/hour 9 11,4 KWh saved/day 0,22 0,27 TOT KW/h saved/year 79 100 TOT Kg CO2 avoided/year * 42 53 Money saved/year 16 € 20 € * Italian average price and CO2 factor: energy price and CO2 factor could vary depending on the Country The money saved in the years can already justify a possible extra-cost on FAAC boards. 10

11 Connectivity The E145 board features an expansion slot for connecting the GSM, Ethernet and WiFi modules. With these modules the board can be remote-controlled via standard communication channels (i.e. internet) with the following related advantages: The installer can offer top-class maintenance services thanks to the remote monitoring of the system and to the possibility of being informed by the board in the event of faults or if a certain number of cycles has been reached Business customers can insert the automated system in their centralized control systems without having to use expensive interfaces, such PLCs. The final residential customer can control his/her board using a smartphone or insert it in a Home Automation system. 11

12 Connectivity The E145 board can be programmed by display or connected to a PC or a MAC. Using the simple and user-friendly EasyBoard programming software, you can choose whether to follow the Wizard guided installation or customize your system in all its parts. It will be also possible to program the SLHP remote controls directly on the board without having to use the SLHP decoder (future development). 12

13 Comparison between 230V boards
Features FAAC 452MPS 455D 462DF E 045 E 145 Board and motor power supply 230V AC 90V ÷ 260V AC SAFEzone with obstacle detection (with SAFEcoder Absolute Encoder) GREENtech (energy saving and switching power supply) ✓ (sleep in standby) Automatic set-up Display LED LCD Available logics 6 8 10 + 7 Electronic deceleration USB functions (SW update, data backup) 2Easy BUS Connectivity (X-COM/G-COM/NET-COM/etc) Programming via PC/MAC FAACTOTUM Password protection ✓ (via PC) Built-in timer Electric lock outputs 1 2 Limit switch inputs Programmable inputs/outputs Type of radio receiver RP Omnidec Omnidec and RP Transmitters stored on the board 256 1.600 Photocell inputs Tradition. only BUS BUS & tradition. Control of operators for sliding gates Full diagnostics 13

14 Retro-compatibility: E045 - Photocells
When replacing an electronic board with standard photocells already installed (e.g. 452MPS, 455D), with the E045, equipped with BUS input only, there are different solutions: Replacing the old photocells with BUS photocells in order to increase the installation protection and efficiency: 2Easy BUS is FAAC proprietary and therefore is not compatible with competitor’s boards or accessories; moreover BUS photocells have an extreme power efficiency. Use BUS XIB interface (cod ) that allow using standard input photocells with 2Easy BUS connection. BUS XIB INTERFACE 14

15 Retro-compatibility: E045 – Radio receiver
Replacing an old electronic board (452MPS, 455D, etc.), the following cases, related to radio system, could happen: CASE 1. External or wire-connected receiver CASE 2. RP receiver plug-in (5 pin) CASE 3. External receiver PLUS/PL with Decoder/Minidec plug-in (5 pin connector) CASE 1. EXTERNAL OR WIRE-CONNECTED RECEIVER Just wire the receiver to E045 connector CASE 2 and 3. RP RECEIVER PLUG-IN (5 PIN) or EXTERNAL RECEIVER PLUS/PL WITH DECODER/MINIDEC PLUG-IN (5 PIN CONNECTOR) Both cases have two solutions 15

16 Retro-compatibility: E045 – Radio receiver
Solution 1: eliminate RP receiver or external receiver + decoding board (e.g. PLUS + MINIDEC) and replace them with the XF module (3 pin) with the same frequency (433 or 868) of the old system Re-program ONLY ONE transmitter SLH/DS or ALL the RC transmitters. Possibility to store transmitters on USB memory. RP E045 16

17 Retro-compatibility: E045 – Radio receiver
Solution 2: keep RP receiver or external receiver + decoding board and plug it on the Interface Adaptor (cod ) in order to wire it to the E045 NO transmitters have to be re-programmed RP Interface adaptor Wire to E045 connector 17

18 Retro-compatibility: E145
The new E145 is equipped with both 2Easy BUS and standard photocell inputs (opening and closing), and both the OMNIDEC XF radio connector (3 pin) and RP connector (5 pin): any type of connection can be done. Moreover 452MPS and 455D connectors are pin-to-pin compatible (all but the electro-lock one) with the E145 connectors; it is therefore even faster and easier replacing an old board with E145, because the wiring remain the same. 452MPS and 455D connectors pin-to-pin compatible 455D connector pin-to-pin compatible 18

19 Contents Why new 230V boards? Market positioning
A few words about the new 230V boards USPs 19

20 USPs: E045 and E145 1 Easy programming and Display
Integrated switching power supply and pilot relay redundancy Radio programming from board with integrated Omnidec Compatibility with the whole range of 230V operators for swing-leaf gates Compatibility with current 230V boards Large connectivity Absolute BUS Encoder support  Safety and accuracy Software update and saving of the configuration via USB 2 3 4 5 6 7 8 20

21 USPs: only E145 9 Compatibility with 230V operators for sliding gates (only E145) Visualization and programming using PC/MAC (only E145) Integrated timer (only E145) Comprehensive diagnostics with event log (only E145) Expansion slot for connectivity (only E145) 10 11 12 13 21

22 1 Easy programming and display
Even the Low-range board features a display for a rapid and easy programming and visualization of the parameters High brightness display: direct sunlight readable Automatic set-up and usual programming similar to 455D: all FAAC control boards for swing-leaf gates, electromechanical and hydraulic, 230V and 24V, feature the same Set-Up procedure 22

23 2 Switching power supply and pilot relay redundancy
Switching power supply integrated on both boards: highly insensitive to interferences; E145 with wide range, 90Vac ÷ 260Vac Remarkable weight reduction thanks to the absence of the transformer Energy efficiency: HW/SW solutions have been adopted to drastically reduce the standby power Motor pilot relay redundancy (5 ones): avoids sticking 23

24 3 Radio programming from board with integrated Omnidec
Only the XF frequency module is needed (433MHz or 868MHz) Radio programming directly on display (+/R1, -/R2) Possibility to create a backup of the memory-stored radios using USB devices For E145, possibility to program the transmitters from PC/MAC and to keep a database of the name associated with the remote control, as SLHP now does (Future development). 24

25 4 Compatibility with the whole range of 230V operators for swing-leaf gates
412 413 415 402 390 422 750 770 / 770N 400 25

26 5 Compatibility with current 230V boards
452MPS 455D 462DF E 045 E 145 The E045 model is largely compatible with 452MPS and offers more potentialities The E145 model is fully compatible with 455D and 462DF and offers more potentialities 26

27 6.1 Large connectivity E045 SAFEcoder USB storage XF 433/868 XT RC
XP15B XF 433/868 XT RC XT SLH LR 27

28 6.2 Large connectivity E145 NETCOM, GCOM SAFEcoder XCOM Module XCOM
Box NETCOM, GCOM USB programming Photobeam SAFEcoder Photoswitch E145 XP15W XP15B Safebeam RP 433/868 XF 433/868 USB storage XT SLH LR XT RC 28

29 7 SAFEcoder: Absolute Encoder
It can be directly connected on the Bus 2Easy input Rapid obstacle detection according to DM 2006/42/EC Directly fitted on the bracket (FAAC PATENT) Easy to retrofit on existing installations Very high detection accuracy (automatic or manual) of the limit switches and of the deceleration points Mechanical stop points can be avoided by setting stop points manually 29

30 8 Software update and saving of the configuration using USB
The USB HOST port, which is present on both boards, can also be used to: Perform an easy update of the firmware when new versions are released Upload or download a programming configuration Upload or download the radio code table (no more need to store at least one SLH Master transmitter) 30

31 E145 Specific features 31

32 9 Compatibility with other 230V operators (only E145)
740 741 844 746 The E145 model is able to control many 230V automations as gearmotors for sliding gates, also in mixed configurations: Two opposed sliding gates A swing-leaf gate (i.e. for pedestrians) and a sliding gate 32

33 10 Visualization and programming of the parameters using PC/MAC (only E145)
The E145 model can be connected to a PC/MAC using the XCOM module or the USB device port in order to: Program each individual parameter on the board Program the energy efficiency function Enter a password to protect the system Easily update the firmware when new versions are released Upload or download a configuration Upload or download the radio code table Program transmitters associated to a database of names (SLHP) 33

34 11 Integrated timer (only E145)
The integrated timer enables you to select weekly or daily procedures with an Outlook-like user interface. “Jolly” periods are selectable in order to create exceptions to standard timer configuration (e.g. Christmas period, summer closing, etc.) 34

35 12 Comprehensive diagnostics with event LOG (only E145)
Real-time detailed check of all errors/warnings and states of every input/output Event LOG : the board memory-stores the last 350 events (opening, closing, obstacle detection, photocells, etc.) for a simplified diagnostics 35

36 13 Expansion slot for connectivity (only E145)
Net-COM G-COM Wi-COM E145 can mount expansion modules to enable remote communication capabilities through the most common and standard protocols like: GSM Ethernet WiFi 36


Download ppt "New 230V boards for swing-leaf gate operators"

Similar presentations


Ads by Google