18/09/2015 Technical and Marketing Resources Ltd.1 CEMSuite Plus Emissions Data logging and presentation software.

Similar presentations


Presentation on theme: "18/09/2015 Technical and Marketing Resources Ltd.1 CEMSuite Plus Emissions Data logging and presentation software."— Presentation transcript:

1 18/09/2015 Technical and Marketing Resources Ltd.1 CEMSuite Plus Emissions Data logging and presentation software

2 18/09/2015 Technical and Marketing Resources Ltd. 2 CEMSuite Plus  CEMSuite is a comprehensive, data logging package designed to work with continuous emissions monitoring systems. For some analysers with a serial output, the data can be exported directly to the host PC; also, data can be acquired from systems with analogue outputs using our advanced interface unit.  The data is stored on the PC hard drive and is used for real- time presentation, historical graphing, alarms and customised reports. CEMSuite has advanced graphing capabilities to provide stunning visual displays of data to enable operators to clearly understand what is happening in their process and gives the ability to correct excursions before they become serious.

3 18/09/2015 Technical and Marketing Resources Ltd. 3 CEMSuite Plus  CEMSuite Plus is a data acquisition and reporting program that gathers data from either a single AMS or a number of groups of AMS.  It is designed to run on a p.c. using a Windows operating system.  It performs real-time data normalisation for pressure, temperature, oxygen and moisture.  It can capture data from 8 separate stacks, each with up to 16 gas/dust/pressure/temperature and process parameters.  Storage capacity is dependent on the size of the hard drive but normally about 10 years with a 20GB hard drive.  Data can be displayed in text or graphical format.  Audible and visual alarms are available to warn operators of upset conditions.  CEMSuite is compliant with WID, LCPD and IPPC

4 18/09/2015 Technical and Marketing Resources Ltd. 4 CEMSuite Plus Components  CEMSuite consists of five inter-connected programs:-  a) CEMCfg - sets up and stores all the required parameters such as normalisation and process data  b) CEMComm - collects data directly from the analyser or an Interface unit and stores it on the hard drive  c) CEMForm - the main data presentation program  d) CEMPort - a data management system that configures stored data for printing in report form or export to other programs such as spreadsheets and databases  e) CEMQual – a module for calculating and displaying the QAL2, QAL3 and AST elements of BS EN 14181

5 18/09/2015 Technical and Marketing Resources Ltd. 5 CEMForm  CEMForm is the display module for CEMSuite Plus and measurement data is displayed in alpha-numeric and graphical form  CEMForm converts raw data from the database into a number of forms including mg/m 3 and mg/Nm 3 using normalising data.  The trend screen shows graphical trends for selected measurands over user defined periods. This allows the operator to investigate incidents and long term trends  The trend screen also shows the plant status (on or off) and whether the averaged data is valid, according to European standards.  Two alarm thresholds are provided to advise operators when limits are being exceeded  An event log is provided so that explanations for events can be recorded by the operator

6 18/09/2015 Technical and Marketing Resources Ltd. 6 CEMForm - Real time data

7 18/09/2015 Technical and Marketing Resources Ltd. 7 CEMForm – Trend screen

8 18/09/2015 Technical and Marketing Resources Ltd. 8 CEMForm – Control screen  The Control screen has been devised for processes such as incineration and Gas turbines where the operator can control the process to regulate emissions levels.  The screen works off a pre-determined block average period (normally 30/15 minutes)and enables the operator to view the current average and the new average required to meet the ELV.  The screen also displays the number of valid minute averages within the block average  Using this page operators will able to regulate their emissions so that they never exceed the ELV

9 18/09/2015 Technical and Marketing Resources Ltd. 9 Control Screen

10 18/09/2015 Technical and Marketing Resources Ltd. 10 CEMPort  CEMPort’s main function is to summarise the emission data into a format for submission to the environmental authorities or for internal reporting or analysis.  CEMPort enables an operator to create professional looking reports that can be output to a printer or saved to file. The program makes full use of Windows embedded printing facilities. Furthermore, data can be exported in CSV, HTML or Excel format to enable users to create their own reports.  The WID report is the standard format report for the EA and shows all the required parameters.

11 18/09/2015 Technical and Marketing Resources Ltd. 11 CEMPort – Report Configuration

12 18/09/2015 Technical and Marketing Resources Ltd. 12 CEMPort – Summary Report  There are three types of report available, Summary, Convert and Alarm. The format of the Summary report may be configured by the user to output the following :-  Averaging period  Measurement groups  Raw or normalised or mass data  Averaged or block data  Measurands  Period of the report  Maxima  95 th Percentile

13 18/09/2015 Technical and Marketing Resources Ltd. 13 Summary report

14 18/09/2015 Technical and Marketing Resources Ltd. 14 CEMPort – Convert Report  The format of the Convert report may be configured by the user to output the following:-  Averaged output over a discrete period  Period of the report  Measurands  Measurement groups  Raw or normalised or mass data  Pre-configured reports can be printed at specified times like the end of the day or a shift. They can also be emailed automatically

15 18/09/2015 Technical and Marketing Resources Ltd. 15 Convert Report

16 18/09/2015 Technical and Marketing Resources Ltd. 16 WID Report

17 18/09/2015 Technical and Marketing Resources Ltd. 17 WID Report  This is the report requested by the Environment Agency from WID controlled sites.  It is easy to configure by the operator and performs all the calculations automatically.

18 18/09/2015 Technical and Marketing Resources Ltd. 18 CEMQual  CEMQual is a module designed to assist operators comply with the requirements of BS EN 14181  It accepts data input manually or retrieved from the CEMForm database automatically  It can perform all the key calculations for QAL2, AST and QAL3  It can produce CUSUM, Shewart and moving median graphs  All graphs and spreadsheet data can be printed or output as a JPEG picture.  Fully compliant with EN 14181 and validated by AEA Technology  With the addition of CEMCAL software and an Envirosoft supplied valve system, automatic zero and span tests can be undertaken at pre-determined intervals.

19 18/09/2015 Technical and Marketing Resources Ltd. 19 QAL2/AST analysis

20 18/09/2015 Technical and Marketing Resources Ltd. 20 Control Chart data entry

21 18/09/2015 Technical and Marketing Resources Ltd. 21 CUSUM Drift Chart

22 18/09/2015 Technical and Marketing Resources Ltd. 22 Shewart Chart

23 18/09/2015 Technical and Marketing Resources Ltd. 23 Moving Median Chart

24 18/09/2015 Technical and Marketing Resources Ltd. 24 Input unit  Accepts analogue inputs from most analysers  Will accept digital inputs (0-5V)  Supplied in an industrial weather proof cabinet  Low voltage directive (LDV) and CE compliant

25 18/09/2015 Technical and Marketing Resources Ltd. 25 Data Storage Unit  The DSU provides long term raw data storage (20Gb) and data back up  It carries out high speed data communications  It can provide data re- transmission from serial to analogue  It automatically updates the host PC if it is turned off for any period

26 18/09/2015 Technical and Marketing Resources Ltd. 26 Multi-analyser system with Input unit

27 18/09/2015 Technical and Marketing Resources Ltd. 27 CEMSuite Plus  We believe that CEMSuite Plus offers new levels of reliability and ease of use to operators of all kinds of regulated processes.  The program is easy to navigate and can be configured to cover most requirements.  The Software is written co-operation with the Regulatory authorities, current CEN standards and guidance to ensure full compliance.  Envirosoft is a specialist company that only creates data logging packages for environmental monitoring systems.  We offer peace of mind to operators of all processes because we can provide the expertise and service that they require to ensure they meet their regulatory obligations.