An introduction to the Galaxy DIMENSION range of control panels October 2012 Honeywell Security (Australia)

Similar presentations


Presentation on theme: "An introduction to the Galaxy DIMENSION range of control panels October 2012 Honeywell Security (Australia)"— Presentation transcript:

1 An introduction to the Galaxy DIMENSION range of control panels October Honeywell Security (Australia)

2 S.P.A.C.E.R. Safety Exits/Fire Exits Fire alarm tests
Any site specific safety aspects Restrooms/Toilets Honeywell Safety Policy

3 S.P.A.C.E.R. Agenda: Start: 09:00 Tea/Coffee: 10:30 -10:45
Lunch: :30 – 13:30 Tea/Coffee: :00 -15:15 Finish: :30

4 S.P.A.C.E.R. A sales introduction to the Galaxy DIMENSION
Purpose (Objective) A sales introduction to the Galaxy DIMENSION To give you knowledge Reason to let you make informed decisions

5 S.P.A.C.E.R. Code of Conduct Silence pagers and cell/mobile phones
Cannot address every issue however, all open issues will be recorded to ensure that it is covered (PARKING LOT if needed) Minimize side conversations Every question is important, please ask Relaxed, informal atmosphere and enjoy yourself

6 S.P.A.C.E.R. Expectations By the end of this training, we expect the audience will: Be able to comfortable in selecting the Galaxy DIMENSION Audience: do you have any additional expectations? Know the Information or where to find it

7 S.P.A.C.E.R. Responsibilities Presenter: Audience:
Present subject material engagingly. Answer on-the-fly questions, or defer to the parking lot as necessary. Follow up with parking lot queries and offline questions. Steer audience to additional resources where necessary. Audience: Please follow code of conduct to help us stay on the agenda. Participate! Identify subject areas that particularly affect your applications, so we can follow up offline.

8 Galaxy Series: History
Microtech Security: 1990 Headquarters: East Kilbride, Scotland Based: East Kilbride, Scotland Ademco Microtech: 1995 Headquarters: Pittway Corporation, Chicago, Illinois Based: East Kilbride, Scotland Started as small company in Scotland with 12 people Purchased by Ademco – Manufacturing moved from the UK to Czech republic & now to China. Honeywell has over 130k + people. – Through all these changes Galaxy has stayed the same Honeywell Security: 2000 Headquarters: Morristown, New Jersey Based: Newhouse, Scotland

9 Galaxy Control Panels Galaxy Classic Galaxy 2 Series Galaxy 3 Series
Launched in Now discontinued*. Launched in 2002 to meet EN Typically Grade 2. In production V1.50 (July 2011) Galaxy 3 Series Launched in 2002 to meet EN Typically Grade 3. Now discontinued#. Galaxy DIMENSION Launched in 2008 to replace the Galaxy 3 Series. Typically Grade 3. In production V6.70 (July 2011) Whilst we wont be seeing all these panels , it shows the History of the product range EN50131 – European Security standard CPIB – Customer Product Information Bulletin – Notice of firmware upgrades, New products etc. See CPIB #012 for details (Customer Product Information Bulletin) * See CPIB #002 for details

10 Galaxy DIMENSION overview
Based on 20 years of Galaxy control panels Integrated access control features Single remote servicing solution Support for graphical “end user” touch screen keypad Multi-language on-site selection option Enhanced interfacing protocol Compliant to all relevant European standards Enhanced walk test operation The Galaxy product has evolved by listening to customers & implementing good ideas. There are a lot of options, whilst they may not make sense or have an application to everyone, they are suitable for someone. Saves time. Saves money. Works better.

11 Key Features / Benefits Galaxy DIMENSION A single control panel
A control panel to suit every intruder/access requirement from 16 to 520 zones With 4 RS485 Data Lines Galaxy GD-520* TouchCenter (Colour Graphics User Interface) Visually impressive, easy to use customer interface DCM (Door Control Module) Enhanced access control With Wiegand Interface Industry standard interface RIO’s – Remote Input Output modules Also use Belden 8723 cable Weekly Timer Schedules Enhanced timing control Cat 5/Cat 5e cable can be used Greater choice for the RS485 Data Line wiring * GD Galaxy Dimension

12 Key Features / Benefits Galaxy DIMENSION Multiple Language options
Multi Channel Audio Audio Confirmation of alarms with Listen In Only option 6-Way Trigger Lead 6 extra outputs from the main board on a flying lead Control End Users can easily and directly control electrical systems Remote Servicing Suite V3.XX Works with Windows 7 (64 bit) operating system RSS – Galaxy software - has Keypad simulation built in, ideal for remote servicing RSS can connect by – DIRECT, PSTN, ETHERNET Multiple Language options Installer can select on-site from a cluster of languages

13 Additional Features / Benefits Galaxy DIMENSION
New Menu Options/Changes Walk Test (Menu 31) Silent Walk Test and View the progress of the Walk Test Codes (Menu 42) Enhanced Timer/Schedules Timer Control (Menu 45) Enhanced Timer/Holiday control Good Ideas that have been implemented Silent walk test used to be audible only (customer feedback) Timers (Menu 65) Weekly Timer Schedules Access Control (Menu 69) DCM (Door Control Module) programming

14 Galaxy DIMENSION Hardware Extra header for the 6-Way Trigger Lead
The outputs are rated to sink, not supply, 100 mA. This header can also work with the Trigger Lead (Order Code: A229) Outputs already on Board These outputs can be controlled by Touchcenter

15 Galaxy DIMENSION Compliant with EN50131, Security Grade 3, Class II
Compatible with all Classic Galaxy and Galaxy 3 Series peripherals Uses existing and familiar Galaxy user and programming interface 16 zones / 8 (+6) outputs onboard Integrated PSTN* V.22 dialler Integrated RS232 communication Powerful and intelligent PSU# Rated at: 2.5 A (Non Grade 3) 1.0 A (Grade 3) Large Box Up to 2x 17Ah batteries SMS is also available * Public Switched Telephone Network # Power Supply Unit

16 Galaxy DIMENSION: Panel range
Brief overview PSU output 2.5Amp ( 1.4Amp – used to supply the 2x 14Amp batteries) 1500 events log memory – 1st in - 1st out + Trace – Records independently last Alarm activation (5x events) even if main log is overwritten MANUALS – Page: 1-1 Galaxy variants G-1 Approvals F-4 Current consumptions of modules etc. F-2 F-3 Module Size specifications F-1 Panel specifications * Single Pole ChangeOver

17 Galaxy DIMENSION: System Architecture
4x Data lines Cat5/5e – proven Belden 8723 – PROVEN Cat 6 – Not officially tested – Not the cheapest, simply the best ADT / Chubb in Europe have Standardised on Galaxy RS485 Data Line (each 1 km)

18 Galaxy DIMENSION: System Architecture
RS485 Data Line 2 Mk7/Mk 8 LCD Keypad Mk7/Mk8 KeyProx RS485 Data Line 3 RS485 Data Line 4 RS485 Data Line 1 TouchCenter ISDN Imod TouchCenter Full VGA TouchCenter Full VGA Prox PSTN dialler Ethernet Module MAX4 Proximity Reader RS232 interface RIO (Remote Input Output) Pictures of Modules Very flexible product – It has been proven over the years to be easy to install & use Printer interface DCM (Door Control Module)

19 Galaxy DIMENSION: TouchCenter (CP040-01/02)
Easy operation for end users Touch-screen buttons with clear guidance More information can be shown to make selections easy, for example, when Setting Groups Event logs displayed as a scroll list for easier comprehension and can also be easily filtered for a Group/Event Engineering access available via virtual emulation of standard Galaxy keypad Customised background image 320 x 240 (1/4 VGA) Resolution with 256 colours User functions include : Set/Unset Changing User Codes Resetting alarms Viewing Event Log Authorise Engineer mode Initiate a download This is what the End User sees as Galaxy

20 A Breakthrough in Simplicity
Simple things work the best IT’S EASY To learn To plan To install To program To maintain 1 user database and 1 PC management package

21 TouchCenter: Group Settings
Up to 32x Areas or Partitions Names can be added to make identification easier

22 TouchCenter - Outputs Actual Output status can also be displayed – Optional With a Mk7 keypad – the outputs would be code protected

23 TouchCenter – Event Log
Simple single line display for each event (up to 1500) Events can be filtered Available through RSS software – Alpha Keypad – Has a 2 line display for each event

24 TouchCenter – User Codes
Easy for end users to maintain codes Mk7 Keypad – MENU 42 – User programming

25 TouchCenter - Help menu screen
End user manual built in- If they loose their paper work – still have it available + can add Company details on another screen

26 TouchCenter - SD Card Customise the screen

27 Simple to use Virtual Keypad
Showing Zone Status – with Voltage & zone resistance + for those who are old fashioned

28 Galaxy DIMENSION: Mark 7 Keypad/KeyProx
Std keypad – with or without Prox Card Prox cards can have different functions (Menu Options Page 6-1) Used to change user codes Show last Alarm info (Security patrol) Door can be hung either side

29 Galaxy DIMENSION: Mark 8 Keypad/KeyProx
New Style Keypad – Blue LCD display Due – Sept / Oct

30 Galaxy DIMENSION PCB colour – old colour

31 Galaxy DIMENSION Blue – New colour which is ROHS compliant
(Removal of Hazardous Substances) lead etc. If Hungry eat the blue board – not your greens

32 Galaxy DIMENSION: Serial Peripheral Interface (SPI) Key
Small, reliable and efficient data storage device Upgrades panel firmware Copies and stores panel programming Memory Stick SPI Key

33 Galaxy DIMENSION : SPI Key
Connector SPI Key header Protecting Cover Menu 71 – SPI Key Upgrades panel firmware Copies and stores panel programming Order Code: A227 (Blank Key) SPI key programmer allows the SPI key to be updated for firmware direct from a PC. Panel programming must be through a Control panel - Power panel down before connecting A must to protect panel data When you press delete, you don’t get a 2nd chance

34 Your Benefits – Access Control
One single integrated intrusion and access system Maximum security with Maximum convenience for End-users DIMENSION Access Control works with many of available Wiegand technology readers and Honeywell readers Offers new opportunities when tendering Go for that Job confident that your offer has the edge Up to 64 doors – 999 users Simplifies operation, training and maintenance both locally and remotely. Reduces the need to buy, stock or train on other products Seamless operation; End-users only need to have a Single card. Fewer opportunities for Lost or mixed-up cards. Offers flexibility and Choice A new DIMENSION in lowering Installer Costs and Growing Installer Business

35 Why is Access Control a Benefit?
One single Installation not two Reduces installation time and costs No separate access cabling needed Simply fit the Door Control Modules straight onto the Galaxy RS485 bus User can use a single card or tag to access areas and control the alarm They can even use the same card/tag at home – further reducing opportunities for operator error. DIMENSION’s Access Control works with most Wiegand technology readers You probably will not have to change readers when incorporating or expanding an existing access system No need to change the cards on most existing access systems, means costs savings and no need to re-programme the cards Offers flexibility and Choice A new DIMENSION in lowering Installer Costs and Growing Installer Business

36 Your Benefits – Integration and Communications
Flexible communications Options Galaxy DIMENSION has a solution whatever the Alarm Signalling requirements Support for existing communication paths such as PSTN, ISDN, or Ethernet Many third party communication devices are also supported New interfacing protocol enables Galaxy DIMENSION as a truly Open System. Integration and communication with large multi-faceted BMS is now even easier Offers you opportunities to diversify or expand services Interface to Winpak; EBI; Prowatch Enterprise Building Integration A new DIMENSION in Security

37 New Access Control Hardware
2-door controller module (DCM) Lock Reader Exit Button Door 1 Door 2 Compatible with all/most Wiegand readers Can work with existing installed readers Can work with existing cards Up to 32 Modules on the 4x data lines More flexible than other competitors - Door contacts for part of the alarm system - Still has off-line mode for emergencies (last 100 cards used) - Unique fully integrated solution - Protects areas of the system Any wiegand reader – any card type up to 40 bit

38 Access Architecture Fully flexible install solutions up to 64 doors
Keyprox Keyprox Keyprox Door control module RS485 Data Bus Door control module Door control module MAX4 MAX4 MAX4 Fully flexible install solutions up to 64 doors Local Management PC Up to 32 DCMs/64 doors Protecting up to 32 Groups/Wards/Sub-systems Up to 1,000 users Common Access event log with 1,500 events recorded in panel (separate from intruder log) Max 4 – New version - Standalone card reader with High Security proprietary cards

39 New Door Control Module
Two Wiegand inputs per DCM (26 – 40 bit with custom mode and card auto-learn) Up to two doors per DCM (Or single door with entry and exit reader) Available with and without PSU (2.75 A) Off line mode will retain access for last 100 valid users Users are assigned an Access Template giving an access time zone to each group (64 Access Templates available on GD-520) New Door Control Mode -Can have an entry and exit reader on one door, or: -Can have a single reader on each of 2 doors, each with a RTE button -Optional version to be available with PSU built-in -Wiegand interface, 26 – 40 bit with custom mode and card auto-learn -Door monitor can be part of intrusion system -Two form C relays for door strike control -Two door monitor inputs -Two RTE inputs -LED output for each reader -Buzzer output for each reader -Menu recall button input -Each door is programmed to a Group

40 Galaxy DIMENSION: Remote Servicing Suite (RSS)
All new GUI* design V3.XX All Galaxy panels supported Works with the Windows 7 (64 bit) operating system Can import database from previous versions of RSS and ACCeSS Lite Network version available One solution for all of Galaxy range * Graphic User Interface

41 How do you benefit with Remote Servicing?
In the UK – each system must be tested twice a year RSS allows one of these visits to be done remotely Also generate a report for the customer Maintenance Visits reduced by 50%

42 All-in-One Remote Servicing Solution
New Galaxy Remote Servicing Suite For Installers New Galaxy Networking Remote Servicing Suite For multiple operators and panels online simultaneously New Galaxy User Management Suite End User software. For example, on-site security manager User management suite is cut down Installer suite (Change users; view logs) - Will charge for End User package Not just a Downloader; we have a Suite of Programs / Tools to help Installer and User

43 All-in-One Remote Servicing Solution
New Programming Screens Divided into 3 Sections LEFT: Top Level Programming MIDDLE: Zone, User or Output RIGHT: Contains the Detail Easy to program Show Menu options when mouse hovers over an option Easy to use interface

44 All-in-One Remote Servicing Solution
The virtual keypad will display info as if you are on site Eg: Zone No. & description – Status, volts & resistance Has the ability to use a Virtual Keypad Allows Live interaction with the Galaxy DIMENSION GD-520 as though you were actually on site

45 Galaxy DIMENSION: Timer Control (Weekly Timer Schedules)
Weekly* Timer Schedules are available each with 42 time slots per week. These are programmed and named (12 alphanumeric characters) by the Engineer (Menu Option 65.1). These Weekly Timer Schedules can then be programmed to: Individual User Codes (To Enable/Disable them) Individual doors (To Lock/Unlock them) Individual Groups (To Autoset) Output addresses (For automatic activation/deactivation) 32 yearly Holiday schedules each with 20 On/Off events Weekly Timer Schedules will be disabled during holidays Variety of times & schedules As there a lot of options available – decide what does the customer wants - Then program 67 Weekly Timer Schedules 2,814 time slots

46 All-in-One Remote Servicing Solution
Report Log Logs can be filtered, & exported to excel & given to customer Also handy for Tech support when sent with panel programming Intruder Logs have Filters to highlight or mask Event Types Log is searchable by Date range and Group

47 All-in-One Remote Servicing Solution
Access logs as well (in/Out) There is also an Audit trail of programming as well Different access levels can be set as well for the use of software Access Log has Filters to Highlight or Mask Event Types Searchable by Date Range, User, Reader and Group (Time and Attendance)

48 All-in-One Remote Servicing Solution
Mimic Screen shows the complete system and where there is any activity White Dots - Zones Black Dots - Outputs Coloured Dots - Activity. Slider buttons - Show Group status Remote Setting is available from this screen Easy view of Output status

49 All-in-One Remote Servicing Solution
Expanded View of the RIO shows exactly where and what Activity is going on The Action Button allows Outputs to be operated or Zones to be Omitted Remotely with the appropriate code for authorization Zone information

50 All-in-One Remote Servicing Solution
DCM’s DCM Mimic Screen showing Door status on all readers Also provides remote Egress (RTE (Request To Exit)) on any reader

51 All-in-One Remote Servicing Solution
Remote Routine Inspection used in the UK Battery is tested hourly RRI (Remote Routine Inspection) to DD263 Manual or Automated RRI (Remote Routine Inspection) Full system Health Check without attending site every other 6 months

52 All-in-One Remote Servicing Solution
Auto generated report – Green = passed Honeywell logo can be changed & customised

53 The Solution That Makes You More Money
You can now offer access control as an integral part of the alarm system No need to quote two separate jobs You can pick up existing access systems installed by others and include them in your alarm maintenance contract –more recurring revenue Reduced cabling requirements means less work for the same money Remote Servicing lets you offer a ‘greener’ option to environmentally aware users No need for an engineer to drive out to service their systems Smaller engineer ‘carbon footprint’ Full range of sales tool available to help you sell the benefits Full support in place from Sales Support teams If facility code is an issue – Could offer Card & Code A DIMENSION To Profitability

54 Galaxy DIMENSION: Summary
What questions do you have?

55 Thank you for your attention


Download ppt "An introduction to the Galaxy DIMENSION range of control panels October 2012 Honeywell Security (Australia)"

Similar presentations


Ads by Google