Choose and Book Installing Security Broker (IA) client.

Similar presentations


Presentation on theme: "Choose and Book Installing Security Broker (IA) client."— Presentation transcript:

1 Choose and Book Installing Security Broker (IA) client

2 Pre-Requisites Installation Testing Uninstalling Upgrading

3 Pre-Requisites before installation  Network Connectivity  Check spine authentication page https://gas.national.ncrs.nhs.uk/login/auth activate  telnet nww.ebs.ncrs.nhs.uk 443  Firewall ports opened – http / https  Bypassing proxy servers recommended  IA compliant PC

4 Compliant PC Windows 98 SE Minimum Platform Requirement Processor266Mhz RAM128Mb Browser VersionInternet Explorer 6.0 (SP1) Smartcard DeviceSee following section Windows Service Packn/a

5 Compliant PC Windows NT 4 Minimum Platform Requirement Processor266Mhz RAM128Mb Browser VersionInternet Explorer 6.0 (SP1) Smartcard DeviceSee following section Windows Service PackSP6

6 Compliant PC Windows 2000 Minimum Platform Requirement Processor500Mhz RAM256Mb Browser VersionInternet Explorer 6.0 (SP1) Smartcard DeviceSee following section Windows Service PackSP4

7 Compliant PC Windows XP Professional Minimum Platform Requirement Processor500Mhz RAM256Mb Browser VersionInternet Explorer 6.0 (SP1) Smartcard DeviceSee following section Windows Service PackSP1

8 Compliant PC  Integrated client (e.g. Emis) may require higher CPU and memory specifications  Anti-Virus and Anti-Spyware software recommended  A Smart card reader, either USB or serial (winNT), with appropriate drivers

9 Compliant Smart Card Readers  Gemplus PC Twin Reader  Gemplus GemPC 430 Reader (does not work on NT 4)  Omnikey 3121 USB Reader  Dell keyboard integrated smart card readers  SCM card readers  HP keyboard integrated card reader  Fujitsu keyboard integrated card reader

10 Compliant PC  Adobe Acrobat Reader 5 as minimum  An account with permissions to install software and edit the registry (local administrator)

11 New Client x Old Client  The new version of the IA client (V7_8_0) can be used for all new installations but is not a required upgrade as the previous version (V7_1_0) continues to be supported  The newer version has some performance and stability improvements and contains an NHS disclaimer. If upgrading the old version must be uninstalled first

12 Summary Installation Process Flow  Ensure all Internet Explorer 6 SP1 cumulative update patches and fixes have been installed  Connect standalone smartcard reader (or USB Keyboard with built-in Smartcard reader) and install drivers  IA installation pack downloaded from http://nww.connectingforhealth.nhs.uk/implement ation/deployment/downloads. Unzip to a temporary location and run “iainstaller_1_0.exe”  Run the appropriate auto-installer from C:\iainstaller\install Continued

13 Summary Installation Process Flow  Add Trusted sites fix and create a CaB desktop icon  Remove role profile screen if required  Copy CaB files to Java folder if multiple Java versions installed  Reboot  Test access

14 Install Summary  Uninstall previous client  IE 6 SP1 patches and fixes have been installed  Connect smartcard reader-Install drivers  Download install pack, run “iainstaller_1_0.exe”  Run auto-installer from C:\iainstaller\install  Add Trusted sites fix  Create a CaB desktop icon  Remove role profile screen if required  Copy CaB files to Java folder if multiple Java versions installed  Reboot  Test access

15 Connect the USB card reader install drivers  Drivers for the GemPlus Twin card reader are installed as part of the IA installation pack. Other card readers including the Omnikey 3121 require additional drivers to be installed  Drivers for the Omnikey 3121 are contained within the IA installation pack but must be installed separately Install Detail

16 Install the IA Client Software  Check that all previous components of the IA are removed from the system  Extract the software to a suitable temporary location and then run the file iainstaller_1_0.exe  The IA Auto Installer will propose a location to extract to dependant on its location. It is imperative that this location is changed to C:\iainstaller Install Detail

17 From c:\iainstaller\install, run the appropriate IA Auto Installer file dependant on the operating system. NOTE: It is vital to ensure that the installation is run from this shortcut as the shortcut contains parameters to ensure the program installs correctly. Install Detail Run the Installer software

18 Accept all the defaults for the GemSafe Libraries until their installation is complete.

19 Select No at this screen to avoid interrupting the auto- installer

20 Accept all the defaults for the GemAuthenticate Client until its installation is complete.

21 Accept all the defaults until the completion of the Java Installation

22 Click No at this screen to avoid interrupting the auto- installer

23 Click No to reboot the system – the auto-installer has finished successfully.

24 Install IE Trusted Sites Fix  Both the old and new IA Installer only adds trusted sites to the HK_CURRENT_USER hive. As a result, only the account logged on during installation has the required trusted sites added Install Detail reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk" /f reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk\nww.ebs.ncrs" /f reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk\portal.national.ncrs" /f reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk\nww.ebs.ncrs" /v https /t REG_DWORD /D 2 /f reg add "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Internet Settings\ZoneMap\Domains\nhs.uk\portal.national.ncrs" /v https /t REG_DWORD /D 2 /f

25 Adding CaB Shortcut Icon  Create a new desktop shortcut to the CaB website:- https://nww.ebs.ncrs.nhs.uk  Copy this shortcut to :- “c:\Documents and Settings\All Users\Desktop” – OS dependent Install Detail

26 Remove role profile screen (old client)  Run C:\Program Files\Syntegra\Device Identification Logger\tktmoncfg.exe. Remove last 4 lines of code. Install Detail

27 Remove role profile screen (new client) Install Detail

28 Disabling Java Automatic Updates  Run “JVM Settings.reg” in the C:\iainstaller\JVM directory if Java still auto updating after installation Install Detail

29 Multiple Java Installations  Copy “c:\Program Files\gemplus\gac\GATicket.jar” to “c:\Program Files\Java\Java_folder\lib\applet” folder  Copy “c:\Program Files\gemplus\gac\TicketApiDll.dll” to “c:\Program Files\Java\Java_folder\lib\ext\x86” folder  Copy “c:\iainstaller\JVM\java.policy” to “c:\Program Files\Java\Java_folder\lib\security” folder Install Detail

30 Testing CaB Access 1.Insert Smartcard and enter passcode Install Detail

31 Testing CaB Access 2.Set Session Role

32 Testing CaB Access 3.Select Role and/or begin using CaB

33 Uninstalling the IA client software Run the IA Uninstaller shortcut in the c:\iainstaller\install directory. You should answer NO to any request to reboot the PC until the process complete confirmation box End the tktmon.exe process from task manager (old client) Check control panel to ensure all IA components have been removed Remove installation directories continued

34 Uninstalling the IA client Software  Device Identification Logger  Gem Authenticate Client V.3.9.1  GemPlus Smart Card Reader Tools  GemSafe Libraries 3.1  Java 2 Runtime Environment,SE V 1.4.2_04  Remove C:\Program Files\Syntegra folder  Remove C:\Program Files\Gemplus folder  Remove C:\TicketAPI folder  Remove C:\Program Files\Java\j2re1.4.2_04 folder

35 Upgrading the IA Software Delete the old c:\iainstaller directory Extract the new IA installation software to c:\iainstaller Run the Remove Old IA shortcut in the c:\iainstaller\install directory Check the control panel to ensure all old IA components have been removed Run the appropriate IA Auto Installer file from the c:\iainstaller\install directory

36 Further Information  This document is provided as a supplement to IG B 0103_21 Installation and Configuration Guide - Security Broker (IA) Client and the Choose and Book Install Reference v3.0 Document which is on the Implementation website – http://nww.connectingforhealth.nhs.uk/implement ation/deployment/downloads