1 Europump's Pump Efficiency Program HI Annual Meeting 2012 St. Petersburg, Fl

2 Remember the Objective 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 2 Save Energy – Selection of properly sized pump – Optimum combination of components – System feedback

3 Current EU Approach Water Pumps – Focus on product – Pump only without drive or VFD – Legislation in Parliament – Expected European Official Journal Summer 2012 Heating Circulators – Focus on Pump, Motor, VFD and Controls – Regulation in place 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 3

4 What is wanted by EU? 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 4 Quantification of Energy Savings Intrinsic product property / scale / index Energy evaluation / comparison of products – mandatory thresholds – Labeling/marking

5 EuP Water Pumps Regulation - draft 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 5 Chapter 1 Subject matter and scope 1. This Regulation establishes ecodesign requirements for the placing on the market of rotodynamic water pumps for clean water duty, including where integrated in other products. 2. This Regulation shall not apply to: (a)water pumps designed specifically for pumping of clean water with temperatures below -10°C or above 120 °C, except as regard to the information requirements of Annex II, point 2(11) to 2(15); (b)water pumps designed only for fire-fighting applications; (c)displacement water pumps; (d)self-priming water pumps.

6 EuP Water Pumps Regulation - draft 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 6 ANNEX II Ecodesign requirements for water pumps 1.efficiency requirements (A) From 1 January 2013, water pumps shall have a minimum efficiency index of MEI ≥ 0.10, when measured according to Annex III. (B) From 1 January 2015, water pumps shall have a minimum efficiency index of MEI ≥ 0.40, when measured according to Annex III.

7 Future EU Approach Pumps – Extended Product Approach – Legislation Draft: Article 7 Revision The Commission shall review this Regulation in the light of technological progress and shall present the result of this review to the Consultation Forum no later than four years after its entry into force. The review shall aim at adopting an extended product approach. ……. 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 7

8 Heating Circulator Proven Approach 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 8 H Q 0.25 0.5 0.751.0 44% 35% 15% 6% % of running hours Total hours depend on geographical region

9 Heating Circulator Proven Approach 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 9 200420082010 1,6 14.928.9 3,3 40.539.7 41,3 25.919.8 52,8 16.89.7 0,8 1.61.5 0,2 0.3 00 0.1 Quelle: Europump

10 Extended Product Approach = Motor Driven System 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 10 Electric Motor Spiral Casing with Impeller Coupling VSD, Control, Monitoring Mains Base Plate Fluid Outlet Fluid Inlet System Feedback

11 Extended Product Approach ? 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 11 Electric Motor VSD, Control, Monitoring index

12 Working Group 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 12 Pump Manufactures - EUROPUMP Motor Manufacturers Drive Manufacturers CEN & CENELEC Scientific support by Technical University of Darmstadt

13 What is needed ? 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 13 Load Profile Definition – Generalized but realistic Reference Definition (Base Case) Market Figures

14 Definitions 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 14 Within EUROPUMP, a methodology and a draft standard will be developed for the determination of energy efficiency of pump units Pump units consisting of pump + power drive system (PDS) are defined as Extended Products EEI (Energy Efficiency Index) proposed to quantify energy efficiency of pump units Activities concerning energy efficiency of pump units are called EPA (Extended Product Approach) Mandate in draft legislation of Water Pumps and new EU ErP work items

15 Methodology for EEI 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 15 The proposed methodology to determine EEI of pump units will comprise two alternative ways: 1.test of the complete pump unit 2.calculations based on so-called Semi-Analytical Models (SAMs) (normally done by the end-supplier of the complete pump unit) For application of the 2nd method, two SAMs are needed SAM of pumps SAM of Power Drive Systems Semi-Analytical Model = mathematical description of component characteristics which only needs limited test data as input to adapt the model to the real component

16 Semi-Analytical Model of pumps 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 16 SAM of pumps is based on hydrodynamic fundamentals and is adjusted by test data at 3 specified flow rates These test data can directly be taken from former tests by the pump manufacturer already mandatory to quantify the energy efficiency of the pump itself (EuP) SAM of pumps delivers rotational speed n and shaft torque T for pump operating conditions (specified by defined load profiles and pressure control curves)

17 Scheme of determination EEI 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 17 Input Software

18 PDS Loss/Efficiency Points CLC TC 22x WG6 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 18 PDSrated torque/ % PDSrated speed/ % 25 100 50100 P V PDS (0;100) P V PDS (50; 100) P V PDS (100; 100) 50 P V PDS (0; 50) P V PDS (50; 50) P V PDS (100; 50) P V PDS (0; 25) P V PDS (50, 25)

19 Pump Load driven by PDS 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 19 PDSrated torque/ % PDSrated speed/ % 25 100 50100 P V PDS (0;100) P V PDS (50; 100) P V PDS (100; 100) 50 P V PDS (0; 50) P V PDS (50; 50) P V PDS (100; 50) P V PDS (0; 25) P V PDS (50, 25)

20 What exists ? 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 20 EEI Energy Efficiency Index for Circulators EEI for Pumps under preparation PDS Classes under preparation Market figures for Europe Efficiency Standard for pumps Legislative mandates to work on EEI

21 What we need on standardization for PDS 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 21 Standard(s) should describe test method(s) for related PDS losses including information on tolerances / allowable uncertainties Standard(s) should specify supporting points within related PDS losses = f(T,n)-map suitable for an interpolation scheme valid within the range of „EEI pump operating points“ Standard(s) should clarify the responsibilities and the procedures to determine and indicate related PDS losses by motor/frequency inverter manufacturers

22 EuP - New Work Items 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 22 ENER Lot 28: Pumps (extended product approach including motors, VSD and controls, where appropriate) for private and public waste water (including all stages including buildings, networks and treatment facilities) and for fluids with high solids content ENER Lot 29: Pumps (extended product approach including motors, VSD and controls, where appropriate) for private and public swimming pools, ponds, fountains and aquariums, as well as clean water pumps larger than those regulated under Lot 11

23 01/08/2015 Frank Ennenbach, Sulzer Pumps Chairman Europump Standards Commission 23 Ecodesign Directive 2009/125/EC Draft Working Plan (2012-2014): issued by DG ENTR bef. Xmas 2011 - Comments by 08.02.2012 finalised by mid-April 2012 Windows Steam boilers (< 50MW) Power cables Enterprises servers, storage and ancillary equipment Smart appliances/meters Positive displacement pumps (depending on lots 28-31) Fractional horse power motors under 200W (depending on lots 28- 31) Heating controls Lighting controls


Download ppt "Europump's Pump Efficiency Program HI Annual Meeting 2012 St. Petersburg, Fl."

Similar presentations


Ads by Google