Draeger BG-4 Self Contained Breathing Apparatus
Procedures for Getting Under Oxygen:
2
Procedures for Getting Under Oxygen:
Put on facepiece properly and tighten straps Open cylinder valve fully, then close one-half turn Observe the monitron or sentinel pressure gauge and warning module: Green indicator light - apparatus O.K Red indicator light - apparatus faulty PSI reading
3
Procedures for Getting Under Oxygen:
Tightly squeeze both breathing hoses and breathe in until a vacuum is produced. Hold your breath for an instant; The vacuum must be maintained, otherwise the straps on the mask must be tightened.
4
Procedures for Getting Under Oxygen:
Check gauge and operation, straps, etc., prior to leaving fresh-air base.