Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa 1 STATUS REPORT.

Similar presentations


Presentation on theme: "Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa 1 STATUS REPORT."— Presentation transcript:

1 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa 1 STATUS REPORT

2 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa2

3 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa3 COOLING FEED-THROUGH QUADRANT SUPPORT TARGET CELL

4 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa4 READOUT ELECTRONICS 3 READOUT PLANS ( 4 PCB + 2 COUPLING BOARDS EACH LAYER 2 DISTRIBUTOR BOARDS SENSORS COOLING BOX INCLUDING 3 LAYERS ( 2 SENSORS EACH LAYER )

5 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa5 DISTRIBUTOR BOARDS SENSORS LAYER 1 : HERMES SENSORS LAYER 3 : PAX SENSORS LAYER 2 : PAX READ-OUT LAYER 3 READ-OUT LAYER 2 READ-OUT LAYER 1

6 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa6 READ-OUT BOARDS HERMES SENSORS COUPLING BOARDS TO DISTRIBUTOR BOARDS

7 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa7 READ-OUT BOARDS PAX SENSORS COUPLING BOARDS TO L3 READ-OUT BOARDS

8 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa8 READ-OUT BOARDS PAX SENSORS COUPLING BOARDS TO DISTRIBUTOR BOARDS ALL THE CONNECTORS MOVED FROM THE BOTTOM TO THE TOP VIEW

9 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa9 DISTRIBUTOR BOARDS TO FEED THROUGHS

10 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa10

11 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa11

12 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa12 L2 READOUT - BOTTOM L3 READOUT - TOP L2 –L3 COLD PLATE

13 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa13 L2 READOUT - BOTTOM L3 READOUT - TOP L2 –L3 COLD PLATE

14 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa14 CONNECTING L2-L3 READOUT BOARDS

15 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa15 L3 COUPLING BOARDS COUPLING SUPPORT FRAME

16 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa16 L3 COUPLING BOARD L3 COUPLING SUPPORT FRAME

17 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa17 CONNECTING THE L3 CABLES

18 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa18 L2 COUPLING BOARDS COUPLING SUPPORT FRAME

19 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa19 L2 COUPLING BOARDS COUPLING SUPPORT FRAME

20 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa20 CONNECTING THE L2 CABLES

21 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa21 L1 COUPLING- BOTTOM L1 COUPLING- TOP L1 COLD PLATE COUPLING & READOUT FRAME L1 READOUT- TOP L1 READOUT- BOTTOM FC5-L1 CABLES FC4-L1 CABLES FC3-L1 CABLES

22 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa22 FC1-L1 & FC2-L1 CABLES

23 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa23 CONNECTING FC1-L1 & FC2-L1

24 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa24 DISTRIBUTOR FRAME DISTRIBUTOR BOARDS (ONLY ON THE TOP)

25 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa25

26 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa26 CONNECTING THE FC4-L1 & FC5-L1 CABLES CONNECTING THE FC3-L3 CABLES

27 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa27 CONNECTING THE FEED-THROUGH CABLES

28 Fz-Juelich, 03/09/2013V. Carassiti, P. Lenisa28  MODULE COMMISSIONING (FERRARA)  COOLING TEST (COLD PLATES AND COOLING BOX PROTOTYPE)  FATIGUE TEST CHECKING THE ABSENCE OF LEAKS COMING FROM THE TEMPERATURE CYCLES  TEST CHECKING THE STABILITY AGAINST THE VIBRATIONS WITHIN THE RANGE OF THE COOLING FLOW RATE