Molded Case Circuit Breakers for the OEM Market
EG 125 Molded Case Circuit Breakers for the OEM Market
2
EG 125 Molded Case Circuit Breakers for the OEM Market
Circuit Protection Bolt-on Version Motor Protection Switch Version Marine SA, Naval SB, 50°C 1/2/3/4 pole 35/ Vac 600Y/347 Vac Max
3
EG 125 Molded Case Circuit Breakers for the OEM Market
Full Line of Accessories Internally mounted signaling and tripping accessories Easy-to-install external operators High Performance, Current Limiting Design Two AIC levels: 480Vac 480Vac Global ratings: UL489 CSA 22.2 No. 5-02 NOM NMX-J-266-ANCE 2002 (date TBD) IEC Added customer benefits Reverse feeding Compact size Molded Case Circuit Breakers for the OEM Market
4
Interrupting Capacity Ratings
UL 489 / IEC Interrupting Capacity Ratings E A UL/CSA/IEC 1,2,3,4-pole Four interrupting ratings
5
Where does the EG 125 fit in the Siemens product range?
NGG EG ED DG 15-125 30-150 N 25 35 H - 65 42 L 100 C 200 T/M FF T/M FA T/M or ETU Yes No Internally Mounted Accessories Frame Amp Range (A) 480 Vac (kA) Trip Unit Global Ratings Future MCCB product offering - completion 2004
6
Accessories EG 125 Complete line of internal & external accessories
Interphase barriers Endcap kit Terminal cover & shields Din rail adapter IEC earth leakage Pad lock device Handle mech. close couple, flex shaft, vari-depth
7
Common Internal Accessories NEG/HEG
Internally Mounted Accessories: *36” wire leads standard Shunt Trip UVR Internal accessories Field installable - remove secondary - does not void UL Breaker trip when secondary cover removed Will not reset w/o secondary cover installed No internal breaker components exposed Wide range of voltage ratings Common w/ J250 - inventory savings Trip accessory - left pole Indication - breaker status - right pole Bell Alarm Aux. Switch Combo Bell/Aux.
8
Common Internal Accessories NEG/HEG
Left Pole - Tripping Shunt Trip UVR Right Pole - Breaker Status Auxiliary Switch 1A-1B 2A-2B Bell Alarm 1M-1B 2M-2B Combo Aux Sw./Bell Alarm Internal accessories Field installable - remove secondary - does not void UL Breaker trip when secondary cover removed Will not reset w/o secondary cover installed No internal breaker components exposed Wide range of voltage ratings Common w/ J250 - inventory savings Trip accessory - left pole Indication - breaker status - right pole EG125 Breaker EG125 Breaker
9
Handle Mechanisms Current Product Offering
Flange Mount Direct Mount Rotary Style Flexible Operator Variable Depth New EG Version No Need to Remove Secondary Cover Less Mounting Time 4X Solution
10
Other Accessories NEG/HEG
CONNECTIONS & MOUNTING OPTIONS Steel wrap-around terminals Aluminum body terminals Plug-in mounting base Rear mounting studs DIN Rail adapter Power distribution (multi-wire) connectors Control wire taps LOCKS & INTERLOCKS Handle padlock (OFF or ON) Handle block Sliding bar interlock Walking beam interlock Internal accessories Field installable - remove secondary - does not void UL Breaker trip when secondary cover removed Will not reset w/o secondary cover installed No internal breaker components exposed Wide range of voltage ratings Common w/ J250 - inventory savings Trip accessory - left pole Indication - breaker status - right pole
11
Motor Circuit Protectors
3-100A Continuous Duty, 3-Pole Component Recognized per UL/CSA/IEC Full line of accessories High Performance Combination I.C. ratings possible up to 480V 3-11 x In Magnetic Pick-up Range Smaller Footprint 13% less panel space than Sentron ED motor circuit protector 40% less volume than Sentron ED motor circuit protector Motor circuit protector version Magnetic only - designed for use in combination w/ motor starter High IC 480 V AC based on control manufacturer’s combination short circuit tests, Slant 600Y/347 V Extended magnetic pick-up range 33% less panel space than the F-frame MCP
12
Collateral Cut Sheet & Product Guide Speedfax
Both can be found on the Siemens website Speedfax