Microscan3 Core – Technical Addendum

Similar presentations


Presentation on theme: "Microscan3 Core – Technical Addendum"— Presentation transcript:

1 Microscan3 Core – Technical Addendum
Upgrading to microScan3 Core from S3000

2 Upgrade options

3 Upgrade Options Other considerations
When is the microscan3 core i/o suitable? Upgrade options: Standalone S3000 Standard 4 m and 5 m Standalone S3000 Advanced 4 m and 5 m The S3000 Advanced variants depends on the application Limitations: The mS3 Core I/O is currently not a viable option for the upgrade of other safety laser scanner products including S300 mini Remote, S300 Professional/Expert and the S3000 Professional/Expert, due to functional limitations Applications using EFI cannot be solved with the microScan3 Core I/O Additionally legacy products such as the PLS (with or without LSI) and RLS Other considerations Currently there is no mechanical or electrical adaptors available

4 microScan3 Core vs. S3000

5 microScan3 Core vs. S3000 Function S3000 Standard S3000 Advanced
Scanning range 4 m / 5.5 m /7 m 4 m / 5.5 m Scanning angle 190° 275° Max. field sets / Fields per set 1 / 3 4 / 3 2 / 4 Contour as reference Yes Static control inputs No 2 (A/B) 1 (A) Incremental encoders Restart External device monitoring Resolutions (mm) 30/40/50/70/150 30/40/50/70/150/200 Basic response time (ms) 60/120 70/90 Measurement data output User software CDS Safety Designer Red = features which cannot be met by microScan3 Core Blue = features which microScan3 Core can offer and S3000 cannot

6 Mechanical installation

7 Mechanical installation
Physical comparison There is currently no exchange adaptor to upgrade from the S3000 and microScan3 Core, therefore a new mounting installation will be needed Below shows the differences between the product dimensions (including system plug): S3000 microScan3 Core

8 Mechanical installation
Mounting bracket /fixing point dimensions Below shows the differences between mounting brackets 1 (direct mounting): microScan3 Core S3000 73 mm 44.1 mm 30.6 mm Ø 5.5 118 mm 120 mm 66 mm 30 mm 159 mm Ø 6.0

9 electrical installation

10 Electrical installation
Electrical connection Conversion There is currently no electrical adaptor. The electrical connections must be manually adapted. Be aware that the electrical connections may be determined by the configuration (see below) Basic configuration Example with S3000 in compatibility mode With field switching Example with S3000 with A input and reset input S30A mS3 S30A mS3 1 2 3 4 5 6 7 24V DC 0 V OSSD1 OSSD2 Reset (in) EDM (in) ERR/Weak (e.g. Res Req) 1 3 2 4 5 6 7 8 24V DC 0 V OSSD 1.A OSSD1.B Reset (in) EDM (in) ERR/Weak FE 1 2 3 4 5 10 11 24V DC 0 V OSSD1 OSSD2 Reset (in) A1 A2 1 3 2 4 5 6 7 8 24V DC 0 V OSSD 1.A OSSD1.B Reset (in) A1 A2 FE