Presentation is loading. Please wait.

Presentation is loading. Please wait.

Tranportation Testing NorthStar

Similar presentations


Presentation on theme: "Tranportation Testing NorthStar"— Presentation transcript:

1 Tranportation Testing NorthStar
“The Power to Exceed”

2 Number of Cycles based on Depth of Discharge Temperature in Celsius
Power Requirements Depth of discharge and operating temperature effect life expectancy With hotel loads today you can expect a nightly discharge rate of 30-60% excluding Less idling will save fuel increasing the return on investment Number of Cycles based on Depth of Discharge Temperature in Celsius 20° 25° 30° 35° 40° 45° 50° Depth of Discharge 100% 300 278 255 233 210 188 90% 355 328 302 275 248 222 80% 428 396 364 332 299 267 70% 529 489 450 410 370 331 60% 676 625 574 524 473 422 50% 903 835 768 700 632 564 40% 1,288 1,191 1,095 998 901 805 30% 2,035 1,882 1,729 1,577 1,424 1,272 20% 3,877 3,586 3,295 3,005 2,714 2,423 10% 11,671 10,796 9,921 9,045 8,170 7,295 8% 17,326 16,026 14,727 13,427 12,128 10,829 5% 35,137 32,501 29,866 27,231 24,596 21,960 2.5% 105,778 97,845 89,912 81,978 74,045 66,111

3 5G Vibration Test NorthStar Batteries exceed 28 times life compared to a conventional flooded battery Will reduce number of batteries required over life of the equipment-reducing down time

4 SLI Competitive Product Comparison Crank Times at Various D.O.D.’s
Real World Testing SLI Competitive Product Comparison Crank Times at Various D.O.D.’s Dynamic Cranking Application 25°C and -18°C 0%, 20%, 40%, 60%, 80%, 100% DoD discharges 500 A crank tests Crank time to 9.0 volts Crank times at various depths of discharge

5 Real World Testing SLI Competitive Product Comparison - 25°C to 9.0 volts - Crank Times at Various D.O.D.’s Fully Charged

6 Real World Testing SLI Competitive Product Comparison - -18°C to 9.0 volts - Crank Times at Various D.O.D.’s

7 SLI Competitor Product Comparison
Dynamic Charge Acceptance to Recharge at Various Depth of Discharge Dynamic Charge Acceptance 25 °C 20%, 40%, 60% DoD discharges 300 W recharge for 24 h, limited to 2.35 Vpc Time to 103% recharge

8 Real World Testing Dynamic Charge Acceptance (DChA) at 25 °C (2.35 Vpc)Time to 103% Recharge at Various Depth of Discharge

9 Competitive Product Comparison Truck Cycle Life Simulation
Real World Testing Competitive Product Comparison Truck Cycle Life Simulation NorthStar Truck Simulation Batteries tested in water 50°C ~50% Depth of Discharge (DoD) Cycling Based on Ah capacity at the RC rate. i.e. 8 hour 5.7 amps (45.6 Ah’s) 100 A Cranking 30 seconds Voltage > 7.2 volts 8-hour, 40 A Recharge Failure determination Voltage < 10.5 volts during discharge Voltage < 7.2 volts during 30 second crank

10 Real World Testing Competitive Product Comparison – 50% 50° C + Crank + Recharge - Truck Cycle Life Simulation


Download ppt "Tranportation Testing NorthStar"