1 Encapsulation Studies

2 Encapsulation Studies
100 modules encapsulated with Sylgard 186 Modules tested before/after encapsulation No channel failures were found In order to test the effect of thermal cycling, envorimental chamber acquired xxx-xxx cycles between -30 C and 50 C and then test Xxx-xxx extreme cycles between -40 C and 80 C and re-test

3 First thermal cycle 36 modules tested so far
xxx-xxx cycles each between -30 C and 50 C Only 1 had any new failed channels after cycles It has 9 new 2 sensor opens (1.7%) Opens vary with time Intermittent connections 1 bond lift-off visible 2 had scratches on PA which might have caused opens after repeated freezing and baking Most channels have no visible damage In total, only 0.05% channels effected

4 Second Extreme Thermal Cycle
17 modules tested so far XX cycles between -40 C to 80 C 7 modules have new failures 1 chip acts if the FE is dead 6 other modules have in total 12 new opens 5 opens at module edges where bonds used to be difficult to make 4 of 6 modules In most cases, bond damage not visible 1.6% of channels effected 0.1% if chip failure excluded