Course Code : CS-252 Computer Organization and Assembly Language Lecture #5 Registers - Flags University of Gujrat

2 Flags Register A special register with individual bit positions that indicate the status of the microprocessor. University of Gujrat

3 Flags Register - - - - OF DF IF TF SF ZF - AF - PF - CF
15 - - - - OF DF IF TF SF ZF - AF - PF - CF CF = Carry Flag SF = Sign Flag PF = Parity Flag TF = Trap Flag AF = Auxiliary Carry Flag IF = Interrupt Flag ZF = Zero Flag DF = Direction Flag OF = Overflow Flag University of Gujrat

4 Status Flags Carry Flag (CF) Set if the result of an unsigned operation is too big to fit into the destination. 1 = carry, 0 = no carry. 1 16 – bit Accumulator Carry Flag = CF University of Gujrat

5 Status Flags Overflow Flag (OF) Set if the result of a signed operation is too wide to fit into the destination. 1 = overflow, 0 = no overflow. + Result of addition of 2 positive numbers cannot be negative! 1 Overflow flag = OF University of Gujrat

6 Carry out from bit 3 on addition
Status Flags Auxiliary Carry Flag (AF) Set when an operation causes a carry from bit 3 to bit 4 or a borrow from bit 4 to bit 3. 1= carry, 0 = no carry. 1 1 1 Carry out from bit 3 on addition 1 Auxiliary Carry Flag = AF University of Gujrat

7 Status Flags Zero Flag (ZF)
Set when the result of an arithmetic operation is zero. 1 = zero, 0 = not zero. 1 Result Zero Flag =ZF 1 University of Gujrat

8 Status Flags Parity Flag (PF) 1 Result
If lower byte of the result contains even number of 1’s, the Parity Flag is set and for odd number of 1’s, the Parity Flag is reset. 1 1 Result Parity Flag = PF 1 University of Gujrat

9 Status Flags Sign flag (SF)
Set when the result of an operation is negative. 1 = negative, 0 = positive. MSB = 1 Negative 1 1 Sign Flag =SF MSB = 0 Positive 1 University of Gujrat

10 Control Flags Direction flag (DF) Interrupt flag (IF) Trap flag (TF)
Used in string operation. If it is set, bytes are accessed from higher memory address to lower memory address. When it is reset, bytes are accessed from lower memory address to higher memory address. Interrupt flag (IF) Indicates if system interrupts can occur. Interrupts will be disabled if a critical operation is being performed that can not be interrupted. Trap flag (TF) Determines if the CPU is halted after each instruction. If it’s set, a debugger will allow single stepping through the program. University of Gujrat