1 Training Course SuperCool 1000 Level 1
Course #P0131

2 Contents Module 1: Introduction Module 2: Inputs and Outputs
Module 3: Features Exam

3 Rapid-access function keys
LCD display for ease of programming LED display readable at a distance Manual switch for mist Pilot lights indicate status of controller outputs 75.4 M1 Tº ºF Pr. Act: Rapid-access function keys

4 Click on image to view video.
System Controls the operation of a high pressure nozzle system by keeping track of humidity and temperature levels. The high pressure nozzle system is the one sold by Victoria Equipment. Controls stir fans. Dairy cows are the main application. It can also be used for poultry and hog production. Click on image to view video.

5 What the Client Gets Product Options Controller; 1 temperature probe;
Contactor box for pump; Instruction manual / wiring diagram. Product Options Up to 3 relative humidity sensors; Indoor or outdoor temperature probes; Valve; Pressure switch; Water meter; Configuration module; Comlink-1 for communications (Bridge)

6 Module 2: Controller Inputs and Outputs

7 Inputs and Outputs 6 x indoor Tº probes 1 x outdoor Tº probe
3 x indoor relative humidity sensors 1 x water meter 1 pressure switch 1 mist output 1 pump 1 mist valve 1 drain valve 3 fan groups.

8 Input: Relative Humidity Sensors
You can select sensors to use. Allows for various strategies: Misting: Compensation on pump operating times; Stop pump if RH too high. Operation of fan groups according to RH level History record over 7 days for minimum and maximum values.

9 Output: Mist Operates according to 4 intensity levels. For each level, user must indicate: Start and stop temperature; Timer settings. For example: Intensity

10 Output: Mist (cont’d) Depending on RH level, controller will modify timer operating times in 2 ways: Humidity lower than comfort zone: Time Off is decreased Humidity higher than comfort zone: Time On is decreased Current Current 50% = % Time Off 50% = % Time On RH Comfort Zone No compensation Pump will stop for a shorter period Pump will operate for a shorter period Max Compensated Max Compensated %RH 50% 60% 80% 90% Low RH set-point High RH set-point

11 Output: Mist (cont’d) Mist operation can be shut off:
If RH level too high; During the night. Mist can be activated if RH too low (dust control)