Presentation is loading. Please wait.

Presentation is loading. Please wait.

Dysrhythmias Disorders of formation or conduction (or both) of electrical impulses within heart Can cause disturbances of Rate Rhythm Both rate, rhythm.

Similar presentations


Presentation on theme: "Dysrhythmias Disorders of formation or conduction (or both) of electrical impulses within heart Can cause disturbances of Rate Rhythm Both rate, rhythm."— Presentation transcript:

1 Chapter 27 Management of Patients With Dysrhythmias and Conduction Problems

2 Dysrhythmias Disorders of formation or conduction (or both) of electrical impulses within heart Can cause disturbances of Rate Rhythm Both rate, rhythm Potentially can alter blood flow, cause hemodynamic changes Diagnosed by analysis of electrographic waveform

3 Relationship of ECG Complex, Lead System, and Electrical Impulse

4 ECG Electrode Placement

5 ECG Graph and Commonly Measured Components

6 Heart Rate Determination

7 Normal Sinus Rhythm

8 Sinus Bradycardia

9 Sinus Tachycardia

10 Sinus Arrhythmia

11 Question Tell whether the following statement is true or false:
The PR interval on an ECG strip that reflects normal sinus rhythm is between 0.12 and 0.20 seconds.

12 Answer True. Rationale: The PR interval on an ECG strip that reflects normal sinus rhythm is between 0.12 and 0.20 seconds.

13 Premature Atrial Complexes

14 Atrial Flutter

15 Atrial Fibrillation

16 Multifocal PVCs-Quadrigeminy

17 Ventricular Tachycardia

18 Ventricular Fibrillation

19 Asystole

20 First Degree AV Block

21 Second Degree AV Block, Type I

22 Second Degree AV Block, Type II

23 Third Degree AV Block

24 Question Tell whether the following statement is true or false:
A “saw tooth” P wave is seen on an ECG strip with atrial fibrillation.

25 Answer False. Rationale: A “saw tooth” P wave is seen on an ECG strip with atrial flutter, not atrial fibrillation.

26 Nursing Process: Care of the Patient with a Dysrhythmia - Assessment
Assess indicators of cardiac output and oxygenation, especially changes in level of consciousness Physical assessment include Rate, rhythm of apical, peripheral pulses Heart sounds Blood pressure, pulse pressure Signs of fluid retention

27 Nursing Process: Care of the Patient with a Dysrhythmia – Assessment (cont’d)
Health history: include presence of coexisting conditions, indications of previous occurrence Medications

28 Nursing Process: Care of the Patient with a Dysrhythmia - Diagnoses
Decrease cardiac output Anxiety Deficient knowledge

29 Collaborative Problems/Potential Complications
Cardiac arrest Heart failure Thromboembolic event, especially with atrial fibrillation

30 Nursing Process: Care of the Patient with a Dysrhythmia - Planning
Goals Eradicating or decreasing occurrence of dysrhythmia to maintain cardiac output Minimizing anxiety Acquiring knowledge about dysrhythmia, its treatment

31 Decreased Cardiac Output
Monitoring ECG monitoring Assessment of signs, symptoms Administration of medications, assessment of medication effects Adjunct therapy: cardioversion, defibrillation, pacemakers

32 Other Interventions Anxiety Use calm, reassuring manner
Measures to maximize patient control to make episodes less threatening Communication, teaching Teaching self-care Include family in teaching

33 Pacemakers Electronic device that provides electrical stimuli to heart muscle Types Permanent Temporary NASPE-BPEG code for pacemaker function

34 Implanted Transvenous Pacemaker

35 Transcutaneous Pacemaker

36 ECG-On Demand Pacing

37 Complications of Pacemaker Use
Infection Bleeding or hematoma formation Dislocation of lead Skeletal muscle or phrenic nerve stimulation Cardiac tamponade Pacemaker malfunction

38 Nursing Process: Care of the Patient with an Implanted Cardiac Device - Assessment
Device function: ECG Cardiac output, hemodynamic stability Incision site Coping Patient, family knowledge

39 Nursing Process: Care of the Patient with an Implanted Cardiac Device - Diagnoses
Risk for infection Risk for ineffective coping Knowledge deficient

40 Nursing Process: Care of the Patient with an Implanted Cardiac Device - Planning
Goals Absence of infection Adherence to self-care program Effective coping Maintenance of device function

41 Interventions Risk for ineffective coping
Support of patient, family coping Setting of realistic goals Allow patient to talk, share feelings, experiences Support groups or referral Stress-reduction techniques Knowledge deficient Patient, family teaching

42 Cardioversion and Defibrillation
Treat tachydysrhythmias by delivering electrical current that depolarizes critical mass of myocardial ceils When cells repolarize, sinus node usually able to recapture role as heart pacemaker In cardioversion, current delivery synchronized with patient’s ECG In defibrillation, current delivery is unsynchronized

43 Safety Measures Assure good contact between skin, pads or paddles
Use conductive medium, 20 to 25 pounds of pressure Place paddles so they do not touch bedding or clothing, are not near medication patches or oxygen flow If cardioverting, turn synchronizer on If defibrillating, turn synchronizer off

44 Safety Measures (cont’d)
Do not charge device until ready to shock Call “clear” three times; follow checks required for clear Assure no one is in contact with patient, bed, or equipment

45 Paddle Placement for Defibrillation

46 Implantable Cardioverter Defibrillator (ICD)
Device that detects, terminates life-threatening episodes of tachycardia or fibrillation NASPE-BPEG code Antitachycardia pacing

47 ICD

48 Question What must a patient with an automatic implantable cardioverter defibrillator (ICD) do? Can continue to go through metal-detection devices at the airport Call for assistance when blood pressure increases Document events that trigger a shock sensation Be compliant with all of the above-listed interventions

49 Answer C. Document events that trigger a shock sensation
Rationale: The patient with an automatic implantable cardioverter defibrillator (ICD) must document events that trigger a shock sensation. The patient must avoid magnetic fields such as metal-detection devices at the airport and call for emergency assistance when feeling dizzy.

50 Invasive Methods to Diagnose and Treat Recurrent Dysrhythmias
Electrophysiologic studies Cardiac conduction surgery Maze procedure Catheter ablation therapy


Download ppt "Dysrhythmias Disorders of formation or conduction (or both) of electrical impulses within heart Can cause disturbances of Rate Rhythm Both rate, rhythm."