1 August 2014 TechConnect Genius Webinar
Kepserver Enterprise with FactoryTalk View Machine Edition Umair Ahmad August 28, 2014

2 Agenda What is Kepware/Kepserver?
Supported drivers and version compatibility Installation and configuration Kepserver with FactoryTalk View Machine Edition/PanelView Plus Troubleshooting Useful tech notes Demo

3 What is Kepserver Enterprise?
Developed by Kepware Technologies (KepserverEX) Data server used to collect data from non-Rockwell Automation controllers We use RSLinx as our data server to collect data from Rockwell Automation controllers

4 Supported Drivers (slide 1 of 2)
A-B Bulletin 900 Automation Direct EBC Automation Direct ECOM BAControlNet (Note: Requires v5.10 firmware) DIRECT-NET EtherTRAK GE Ethernet GE Ethernet Global Data GE SNP (Note: No longer supported for the PanelView Plus 6 terminals) GE SNPX (Note: No longer supported for the PanelView Plus 6 terminals) Hilscher Universal Mitsubishi Ethernet Mitsubishi FX Mitsubishi FX Net Mitsubishi Serial Modbus ASCII Serial Modbus Ethernet Modbus Serial (Master) Modbus Serial unsolicited (Slave) Knowledgebase Link:

5 Supported Drivers (slide 2 of 2)
Modbus Plus (Using Hilscher card, see answer 563581: Hilscher Modbus Plus and Profibus Support for PanelView™ Plus 6) Modbus Unsolicited Serial Omron FINS Ethernet Omron FINS Serial Omron Host Link Omron Process Suite Profibus DP (Master/Slave) (Using Hilscher card, see answer 563581: Hilscher Modbus Plus and Profibus Support for PanelView™ Plus 6) Siemens S5 Siemens S7 MPI Siemens S7-200 Siemens TCP/IP Ethernet Simatic 505 Serial Simatic 505 Ethernet Simulator SquareD TIWAY Host adapter Uni-Telway User Configurable Driver Yokogawa DX Yokogawa DX Serial Yokogawa DXP Knowledgebase Link:

6 Development (PC) vs. Runtime (PVP) Compatibility
IMPORTANT: The configuration file created on the PC must use the same version of Kepserver running on the PanelView Plus Knowledgebase Link:

7 Make Sure You Have the Correct Versions
If the PVP is a V6.1 and the FactoryTalk View ME Studio software is V7.0, KepServer V5.3 should be loaded on the development PC. You cannot have KepServer V5.3 and V5.7 loaded on your PC. You can have KepServer V4.5 and V5.7 or V5.3 on your PC If you have both V4.5 and V5.7 on your PC, make sure you are running the correct KepServer version when creating the runtime file

8 Installing Kepserver on PC
With FTVME V7.0 and greater, you have the option to install V5.7 only or both V4.5 & V5.7.

9 Installing Kepserver on PC
By default, the installation installs neither drivers nor driver help. Check Full Install

10 Kepserver Installed on the PC
Kepserver runs as a service on your PC Make sure you have the correct version of KepServer opened while creating the runtime file.

11 Installing Kepserver on PVP/PVPce/PVP6
Use the Firmware Upgrade Wizard to install Kepserver and associated driver on the PanelView/PanelView CE. (Note: PVP400s and PVP600s – CF card only)

12 Installing KepServer on PVP6
Use the Firmware Upgrade Wizard to enable the Kepware driver on the PVP6 or use the Windows CE operating system. See Answer ID

13 Comfort Zone - RSLinx What do we really know? Driver type
Device info (address) Tag addressing Cables

14 RSLinx Enterprise in FTView
(Confidential – For Internal Use Only) Copyright © 2007 Rockwell Automation, Inc. All rights reserved. Create a Shortcut Create a Driver Create a Device Exposed to FT Studio

15 The basic questions are the same?
Not So Comfy Zone The basic questions are the same? YIKES! Driver type Device info (address) Tag addressing Cables

16 Kepserver in FTViewME Exposed to FT Studio Create a Driver
Create a Device Create a Tag Database Unlike RSLinx Enterprise, everything is done manually But, the process is very similar

17 Developing a KepServer Project Flow Chart
Create Channel, Device and Tags in Kepserver on PC Test tags in Kepserver’s OPC Quick Client Add Kepserver to FTView application and test in Studio Before creating runtime, verify the Default Template name is correct. Upgrade firmware for PanelView Plus with correct Kepserver driver Download and run application

18 Create Channel, Device and Tags

19 Create a Channel Channel – mode of communications: Serial, Ethernet, etc.

20 Create a Device Device – PLC or hardware

21 Create a Tag

22 Test tags in Kepserver’s OPC Quick Client
Review Diagnostics

23 Add Kepserver to FTView Application
Test Display Tag Browse Add Kepserver

24 Before Creating Runtime, Verify the Default Template Name is Correct
Before Creating Runtime, Verify the Default Template Name is Correct. V4

25 Troubleshooting OPC Quick Client
Check driver/device configuration correct Check tag addressing (USE TAG ADDRESS HINTS) FTStudio Browse for tags Test application Kepware version PanelView Plus Review diagnostic file Check installed drivers in PanelView Plus Check cabling

26 Helpful Links Modbus with PanelView Plus: um/2711p-um002_-en-p.pdf Quick Start Guide for Setting up Kepware Communications: Configuring User Configurable Driver (UCON):