1 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900E PUBLIC INFORMATION L11 -Techniques to Increase Efficiency with PanelView™ Plus 6 Applications

2 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION PanelView™ Plus 7 2

3 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION 3 PanelView™ Plus 7 Introduction  New Displays  Increased Screen resolution  Wide Screens  More Sizes – Up To 19”  More Certifications  ATEX  INMETRO  Marine Optimized value with two distinct platforms Better hardware, easy migration!

4 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Housing & Bezel Material PlasticAluminum Communication Single EthernetDual port Ethernet, embedded DLR Op. System / Software Windows CE 6.0 w/standard features set FTView ME 7.0 Application limits: 1 Controller, 25 Screens, 200 Alarms Windows CE 6.0 w/extended features set FTView ME 8.10 Application limits: None Processor / Memory ARM / 512 MB flash and RAMX86 / 1 GB flash, 512 MB RAM Power Options DC onlyAC and DC User Interface Resistive, touch screen onlyResistive, touch or touch/keypad combo Certs UL, CE, ATEXUL, CE, Marine, (future: ATEX, INMETRO, Conformal Coating) PanelView™ Plus 7 Standard vs. Performance 4 PvP7 - Standard AFC: Jan, 2015 PvP7 - Performance AFC: Q3, 2015 Avail Sizes (in): 6.5, 9.0W, 10.4, 12.1W, 15.0, 19.0 Avail Sizes (in): 4.3W, 5.7, 6.5, 9.0W, 10.4

5 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION FactoryTalk® View Machine Edition v8.0 5

6 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION FactoryTalk® View Machine Edition 8.0 August 2014 Release 6 Configuration and Application Building Simplified project management Resizable alarm editor Application Manager workflow Improved Run-Time Experience User Management controls Improved Domain Authentication Security Code changes Improved audit trail User Group Security functions Application loading Error-proofing Unsolicited Messages Expanded Operating System Support Windows 8 Windows 8.1 Update Windows 2012 Server R2 Last release supporting older Microsoft Operating Systems & FactoryTalk View Machine Edition versions Streamlined Installation Unattended Install Uninstall FactoryTalk View Tool Support for PanelView™ Plus 7 Terminals

7 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Configuration and Application Building FactoryTalk® View Machine Edition 8.0 Feature Information

8 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Simplified Project Maintenance 8 Improved handling of multiple FactoryTalk® View Machine Edition applications on same PC Each project has its own private security configuration Users, Groups, and policy AID 608976 Overview Allows user to restore a project (MER/APA) without overwriting any other project’s security configuration No need to be ‘careful’ when restoring MER or APA Benefits VME

9 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION 9 Resizable Alarm Editor Alarm Editor allows resizing of the various tables in the dialog Overview Easier to manage and configure Alarms Benefits VME

10 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Application Manager Workflow 10 Application Manager returns to starting step when an operation completes Application Manager allows user to overwrite existing backup (APA) files when creating a backup file project when restoring a backup (APA) or runtime (MER) file Overview Allows user to immediately initiate next operation saving time Benefits VME

11 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Improved Runtime Experience FactoryTalk® View Machine Edition 8.0 Feature Information 11

12 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION 12 Runtime User Management VME New User Management objects to manage native FactoryTalk and Windows-linked users Add, remove, and modify user accounts while an MER is running Security configuration changes persisted in the MER AID 613707 Overview No longer need to rebuild MER to change security configuration Support for 21 CFR Part 11 compliance Benefits

13 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Windows 2008 and 2012 Server Active Directory Authentication Support 13 Added LDAP and LDAP over SSL to the PanelView Plus terminals Existing application will work in Windows 2008/2012 domains, unchanged LDAP configuration applies to the terminal, not the application AID 609098 Overview Windows-linked user and groups support centralized account management Support for 21 CFR Part 11 compliance Benefits VME

14 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION 14 Login Button Improvements Support Domain Integration Enhanced login button supports Control of domain field visibility Allow/ Disallow domain field editing Domain field content can be fixed, user entered, or bound to a tag Obscure user name entry with ‘#’ Overview Saves operator time Requires less Operator knowledge Benefits VME

15 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Changes to A-P Security Codes 15  Assume a user is a member of more than one group. The groups have the following configured security codes At runtime the user’s effective security codes have changed in v8.0 and later, compared to earlier versions Runtime Security Configuration ABCD Group1 XXX Group2 XXX Effective A-P Security Codes ABCD FactoryTalk® View v8.0 XX FactoryTalk® View v7.0, and earlier XXXX All of a user’s A-P configurations are ANDed together in v8.0, and later If a user is a member of more than one A-P configuration, at run-time the user’s effective A-P Security Code permissions will be the most restricted set previous versions granted the most lenient effective Security Code A-P permissions AID 617466 Overview Support for 21 CFR Part 11 compliance Benefits VME

16 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Capture Value Before Change VME VSE FactoryTalk® AssetCentre Audit Log View Audit Message Detail When you change the numeric or string input value, the previous value is logged and shown in the FactoryTalk® AssetCentre Audit Log Overview Provides improved tracking of operator actions Improves support for 21 CFR Part 11 compliance Streamlines troubleshooting process Benefits

17 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION RSLinx® Enterprise Accepts Unsolicited Messages 17 Controllers send Direct Tag information to HMI application under programmatic control Control program determines when information is transmitted to HMI AID 614323 Overview Unsolicited messages can be used to reduce network traffic for ‘exception’ events (Ex. Alarms) Normal tag data is polled, or solicited, from the controller Benefits VME VSE

18 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Improved System Error-proofing 18 When building MER system warns if a shortcut uses an unsupported network, Ex. RIO When loading MER on PanelView Plus terminal will warn if MER project resolution (size or aspect ratio) does not match physical terminal MER shortcut(s) references a network the terminal cannot support, Ex. PanelView™ Plus 7 and DH+ Overview Saves wasted time Benefits VME

19 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Expanded Operating System Support FactoryTalk® View Machine Edition 8.0 Feature Information

20 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Expanded Operating System Support 20 Windows 8, Windows 8.1 Update and Windows 2012 Server R2 join the list of supported operating systems in this release. VME VSE

21 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Additional PanelView™ Plus Platform Support 21  PanelView™ Plus Platforms  PanelView™ Plus 6 Compact 1000  PanelView™ Plus 7 Standard  PanelView™ Plus 7 Performance VME

22 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Removing Operating System Support 22  FactoryTalk® View v8.0 is the LAST release to support  Windows XP [any edition or SP]  Windows Vista [any edition or SP]  Windows 2003 Server [any edition or SP] VME VSE

23 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Removing PanelView™ Plus Platform Support 23  FactoryTalk® View 8.0 is the LAST release to support v3.2 and v4.0 MER  Using release after v8.0, it is not possible to create v3.2 or v4.0 MER  Using release after v8.0, it is not possible to execute v3.2 or v4.0 MER  Using release after v8.0, it IS possible to open and convert legacy applications the newer project format VME

24 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Lab Overview 24  Great Demo style  Demo of a scenario & then followed by a how to for that scenario  8 Scenarios  Runtime User Management  Managing Machine / Process Parameters with Recipe OCX  Monitor Application Remotely with ViewPoint  Remote Display Access with VNC  Log Production Data with Datastore Plus OCX – data log file is stored in a mapped network folder  Switch Application Language to Operator’s Native Language  Reuse Common HMI Components with Global Objects  Access Reference Material from Terminal with PDF Viewer – PDFs are stored in a mapped network folder  Each scenario is modular – can do them in any order

25 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION RFID Demo Section 25 Use the top line for the user name and the rest of characters from the second line for the password So in this example 50892 is the user name and 619CCC is the password. The password is case sensitive User ID could be 4 numbers instead of 5

26 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. www.rockwellautomation.com Follow ROKAutomation on Facebook & Twitter. Connect with us on LinkedIn. Rev 5058-CO900F PUBLIC INFORMATION Thank You