HF Calorimeter PMT Upgrade R&D Yasar Onel for University of Iowa, Fairfield University, INFN, Trieste.

Slides:



Advertisements
Similar presentations
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Advertisements

Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
CMS Hadronic Forward Calorimeter Restoration of Functionality Iowa, BU, FNAL severe descoping of HF in 2002 $$ for HB, tracker tail catcher for late developing.
Digital Filtering Performance in the ATLAS Level-1 Calorimeter Trigger David Hadley on behalf of the ATLAS Collaboration.
Peter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute The HERA-B RICH counter.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
ECAL Spike Plot Approval ECAL Anomalous Signal Plots Approval Adi Bornheim for ECAL
LHCf: a LHC Detector for Astroparticle Physics LHCf: a LHC Detector for Astroparticle Physics Lorenzo Bonechi on behalf of the LHCf Collaboration * University.
Calorimeter1 Understanding the Performance of CMS Calorimeter Seema Sharma,TIFR (On behalf of CMS HCAL)
Off-axis Simulations Peter Litchfield, Minnesota  What has been simulated?  Will the experiment work?  Can we choose a technology based on simulations?
How to Build a Neutrino Oscillations Detector - Why MINOS is like it is! Alfons Weber March 2005.
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
J. Leonard, U. Wisconsin 1 Commissioning the Trigger of the CMS Experiment at the CERN Large Hadron Collider Jessica L. Leonard Real-Time Conference Lisbon,
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
Far forward angle physics at the LHC E. Norbeck and Y. Onel University of Iowa For the 24th Winter Workshop on Nuclear Dynamics South Padre Island
M.Gallinaro, ``Innovative Particle and Radiation Detectors’’, Siena, October slide 1 The CDF MiniPlug Calorimeter Forward Physics Conceptual.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
We observe two classes of anomalous signals in HCAL 2) Cherenkov light produced by interactions in the window of the Forward Calorimeter PMTs ¼ photoelectrons.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Study of HF pmt high tail signal FNAL: Jim F, Rick Vidal Iowa: Ugur Akgun, Asli Albayrak, Warren Clarida, Antony Moeller, Yasar Onel, Justin Parsons, Taylan.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Adam Para, Fermilab, April 26, Total Absorption Dual Readout Calorimetry R&D Fermilab, Caltech, University of Iowa, Argonne National Laboratory,
Proposal for Generic R&D on EIC Detectors Yasar Onel University of Iowa.
Development of A Scintillation Simulation for Carleton EXO Project Rick Ueno Under supervision of Dr. Kevin Graham.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
CMS Hadronic Endcap Calorimeter Upgrade Studies
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Electromagnetic Calorimeter for HADES at SIS100: MAMI and CERN test results Lead-glass modules Tests -  beam at MAMI energy resolution -  - /e - beam.
CMS Calorimeter HB- HB+ HE- HE+ HF- HF+ HO-2 HO-1 HO0 HO+1 HO+2
T. Sugitate / Hiroshima / PHX031 / Nov.01 The Photon Spectrometer for RHIC and beyond PbWO 4 Crystal Density 8.29 g/cm 3 Radiation length 0.89 cm Moliere.
Luminosity Monitor UKNF Meeting 7 June 2010 Paul Soler, David Forrest Danielle MacLennan.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
May 1-3, LHC 2003V. Daniel Elvira1 CMS: Hadronic Calorimetry & Jet/ Performance V. Daniel Elvira Fermilab.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
E. A. Albayrak, HCAL Meeting, Fermilab, Nov HE CALORIMETER DETECTOR UPGRADE R&D STATUS E. A. Albayrak for The University Of Iowa Fairfield University.
LHC The Large Hadron Collider (LHC) is an accelerator with 27 km circumference. Being built on the France- Switzerland border west of Geneva. It will start.
FIT (Fast Interaction Trigger) detector development for ALICE experiment at LHC (CREN) Institute for Nuclear Research (INR RAS) National Research Nuclear.
The experimental setup of Test Beam HE EE ES BEAM  A slice of the CMS calorimter was tested during summer of 2007 at the H2 test beam area at CERN with.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
Aerogel Cherenkov Counters for the ALICE Detector G. Paić Instituto de Ciencias Nucleares UNAM For the ALICE VHMPID group.
Calibration of uniformity between LYSO crystals Zhigang Wang Institute of High Energy Physics, CAS The Third International Workshop on the High.
Feb 24, Abnormal Events in HF: TB04, Simulation, and Feb.08 Fermi Testbeam Anthony Moeller (U. Iowa) Shuichi Kunori (U. Maryland) Taylan Yetkin (U.
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
Quartz Plate Calorimeter Prototype Hardware & Preliminary Test Beam Data Anthony Moeller The University of Iowa.
Chapter V Radiation Detectors.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements:  Expected total rate for 9.25 < R < 120 cm: 12.1 MHz:
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
PMT AFTERPULSE STUDIES By Ugur Akgun The University of Iowa.
SHIP calorimeters at test beam I. KorolkoFebruary 2016.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
The PSD at Pb-Pb run PSD drawbacks at Ar beam
Light mixer proposal Arjan Heering, Anton Karneyeu
Group CERN Taylan Yetkin Post-Doctoral Research Scholar.
HE Calorimeter Upgrade Studies
HCAL Commissioning and Related Activities
HE Calorimeter Upgrade Studies
Chris Smith California Institute of Technology EPS Conference 2003
Separation of Scintillation and Cerenkov Light
Dual readout calorimeter for CepC
Performance test of a RICH with time-of-flight information
Presentation transcript:

HF Calorimeter PMT Upgrade R&D Yasar Onel for University of Iowa, Fairfield University, INFN, Trieste

HF Detectors Readout Readout Box IP  11 m away from IP. Fact: High energetic muons or residues of late hadron showers may reach to HF Readout Box. 11/19/20082CMS Upgrade Workshop, Nov 19-21, 2008

HF PMT Specs Hamamatsu R7525 PMT has 8 stages dynode 25 mm diameter bialkali photocathode borosilicate glass window maximum QE at 450 nm (23%) The glass window can be source of Cerenkov light itself 11/19/20083CMS Upgrade Workshop, Nov 19-21, 2008

HF PMT Events These events are due to Cerenkov radiation from particles directly hitting the PMT window. The glass window is plano-convex. – 1mm thick in center – 6.1mm thick at the edges 11/19/20084CMS Upgrade Workshop, Nov 19-21, 2008

Energy GeV Pion Beam HF PMT Events (continued) The PMT window events were seen in HF 2004 data. (Left figure) Very high energy events were also seen in TB2004 analysis (right figure) by A. Moeller. See a talk from the analysis: pdf pdf Then it was confirmed in 2007 by using a HF mock up by Jim Freeman et al. We also performed two test with a stand-alone HF PMT at Fermilab and at CERN in Energy GeV Muon Beam 11/19/20085CMS Upgrade Workshop, Nov 19-21, 2008

Muon Energy Spectrum 150 GeV Tower 14 The  200 GeV peak is from the muons interacting with HF PMT. The  4 GeV peak is from the muons interacting with HF body. Large tail are events are due to the muons which creates more p.e. in due to the interactions with PMT window. HF Test Beam 2004 This is potentially problematic for forward jet tagging, MET, and luminosity precision. We need an upgrade studies right away! 11/19/20086CMS Upgrade Workshop, Nov 19-21, 2008

R&D PROPOSALS 11/19/20087CMS Upgrade Workshop, Nov 19-21, 2008

HF PMT System Upgrade We propose to upgrade HF PMTs with two photo-sensors (PMTs) QE of 45% peak or more Thin glass window less than 1 mm thick, and walls cannot generate Cerenkov light (for PMT, a metal envelope) We consider mini-PMTs (2 per tower, total 3456) or multi-anode PMTs (total 1728) 11/19/20088CMS Upgrade Workshop, Nov 19-21, 2008

One of the Candidates Hamamatsu 16- Anode PMT (R7600U-200) QE peaks at 400 nm with 45% (ultra bialkali) within the range of nm. The metal envelope eliminates the Cerenkov light in the walls. A very thin window (0.6 mm) which also eliminates Cerenkov light production due to head on muons. It gives possibility to assign two channels per tower (or equivalently per light-guide.) 11/19/20089CMS Upgrade Workshop, Nov 19-21, 2008

Benefits of Mini /Multi-Anode PMT The HF upgrade plan includes changing PMTs with new generation PMTs. The replacement will help to tag “PMT Events” have better energy resolution Increase muon signal efficiency 11/19/200810CMS Upgrade Workshop, Nov 19-21, 2008

Tagging “PMT Events” with Mini-PMT or Multi-Anode PMT 2 channels of PMT per tower can recognize and tag signal event by event when these PMT events occur correct false signal directly by measuring the true signal. If one of the channels in one tower gives large pulse while the other does not, one can correct the signal with the smaller one, given that they cross-calibrate each other. Light Guide Cross-Sectional View Single channel mini-PMT 2 signal channels as “bow-tie” anode connections A traversing muon will only hit one channel, therefore this structure will help to tag “PMT events” 11/19/200811CMS Upgrade Workshop, Nov 19-21, 2008

Better Energy Resolution The energy resolution in HF is determined by the photo-statistics (even for hadronic showers since the signal is mostly generated by  0 s). In current HF PMT the light output is 0.25 p.e./GeV (4 GeV per p.e.). By using new PMTs which has refined bialkali photocathode p.e. yield can be increased by a factor of  1.9 (0.48 p.e./GeV). This gives  33% better energy resolution. Hamamatsu QE of  45% peak or more 11/19/200812CMS Upgrade Workshop, Nov 19-21, 2008

Increase in Muon Signal Efficiency By using high QE-PMT 1 p.e./muon can be increased to 2 p.e./muon. This will increase the efficiency of HF to see a muon signal up to  80%. The benefit is more ability to remove PMT events which are not interacting with HF fibers. 11/19/200813CMS Upgrade Workshop, Nov 19-21, 2008

Short Term Solutions to “PMT Events” Before doing a major upgrade, along with our Fermilab colleagues, we propose to use radiation hard scintillating crystals to tag these “PMT events”. HF PMT Scintillating Crystal Due to the scintillation light from traversing particles (which are the cause of “PMT events”) -the light output, therefore energy reading, will be increased. - also due to the decay time of the crystal the pulse shape will become wider. These features may help to eliminate “PMT events”. Two crystals, namely BGO and LySO, were chosen to be tested. Expectations are * : LySO is faster than BGO (decay time  LySO ~40 ns for LysO and 300 ns for BGO). Light output of LySO is 6 times larger than BGO. * 11/19/200814CMS Upgrade Workshop, Nov 19-21, 2008

Continued… We had beam tests with the proposed R&D in the year of 2008 at Fermilab and CERN. 3 LySo and 3 BGO crystals were installed in CMS for beam collisions. 11/19/200815CMS Upgrade Workshop, Nov 19-21, 2008

TEST BEAM ACTIVITIES 11/19/200816CMS Upgrade Workshop, Nov 19-21, 2008

Test Beam 2008 CERN/FNAL Setup Beam Quartz Calorimeter HF Crystal Setup Small PMT Test Setup 11/19/200817CMS Upgrade Workshop, Nov 19-21, 2008

Test Beam 2008 CERN/FNAL Setup-II The crystals were tested at CERN/Fermilab 2008 beam tests. The main objectives to find the effect of them to muons. Timing, pulse shape, and energy response were also subject of beam tests. The mini PMT was tested as part of CERN 2008 beam test. The main objectives were to find response to beam, to identify if glass window and or side walls are sensitive for Cerenkov light production. 165 cm steel Quartz Plate Veto Beam Mini PMT Trigger Muon Veto HF PMT Crystal Wire Chamber 11/19/200818CMS Upgrade Workshop, Nov 19-21, 2008

Test Beam Participants at CERN 2008 Yasar Onel 1, Jim Freeman 2, Rick Vidal 2, Taylan Yetkin 1, Elif Asli 1 Albayrak 1, Anthony Moeller 1, Burak Bilki 1, Warren Clarida 1, James Wetzel 1, Ferhat Ozok 1, Nasuf Sonmez 3, Kerem Cankocak 1, Aliko Mestvirishvili 1, David Winn 4, Aldo Penzo 5 1: University of Iowa 2: FNAL: 3: Ege University 4: Fairfield University 5: Trieste, INFN We also had shifters from Boston U. (A. Clough, M. Carleton, P.D. Lawson 11/19/200819CMS Upgrade Workshop, Nov 19-21, 2008

Analysis Requirements Required only beam triggered events. Remove beam contamination and applied wire chamber cuts. The ADC counts are converted to charge by using non- inverted conversion table (CMS HF QIE conversions). The fCToGeV conversion is done by using 0.25 p.e./GeV from HF test beam and PMT gain (the resulted conversion is an approximate one). (fC2GeV ~ 0.02 GeV/fC) 11/19/200820CMS Upgrade Workshop, Nov 19-21, 2008

Muon Energy Spectrum Comparison 150 GeV Tower 14 E Long Calibration with 100 GeV e Test Beam. Beam is parallel to the fibers 2008 Test Beam. Beam is parallel to the PMT 225 GeV HFPMT 165 cm steel absorber Calibration with 0.25 p.e./GeV The energy spectrum from HF PMT events are consistent with each other. The peak of the signal from PMT glass is ~200 GeV. N p.e. ~370 sin 2  C eV -1 cm -1 ~340 eV -1 for muons with  1, PMT glass with n  1.5 and 6.1 mm thickness. 11/19/200821CMS Upgrade Workshop, Nov 19-21, 2008

Direct Hit to HF PMT (muons) 225 GeV mu-, without crystal 225 GeV mu-, LySO (0.15mm) LySo signal is ~600 GeV (400 GeV above Cerenkov signal) Average Pulse Shape 11/19/200822CMS Upgrade Workshop, Nov 19-21, 2008

16 GeV proton beam at Fermi Test ConfigurationApproximate Mean, ADC Count w/o Crystal 2.5  0.07 (1) LYSO 650  5 (260) BGO 90  3(36) ADC Counts  100 as amplifier factor  1 1 16GeV proton, NoXtal, No Lucite16GeV proton, 3mm LySO, No Lucite 16GeV proton, 3mmBGO, No Lucite LySO/ BGO ~7.2 11/19/200823CMS Upgrade Workshop, Nov 19-21, 2008

Summary of Crystal Tests The signal with and without crystal configurations were compared. Signal timing were found to be consistent with manufacturer specs. The signal from the “PMT events” is changed with the crystals and the ratios found to be consistent with expectations. The average pulse height distributions are found to be wide which is due to the decay time of scintillating crystals. As a result of these conclusions 6 crystals were installed in HF for LHC beam collisions to make further tests. 11/19/200824CMS Upgrade Workshop, Nov 19-21, 2008

(Run – 175 GeV e - )‏ Typical Pulse Shapes from Mini-PMT The trigger was a scintillator with a mini-PMT. The wide pulse shape is typical. As expected the particles hitting mini- PMT window are producing Cerenkov signal (note the very fast charge collection) 11/19/200825CMS Upgrade Workshop, Nov 19-21, 2008

Other Approaches Two veto counters, one is based on quartz and the other one based on Lucite, were also tested. HF PMTQuartz Plate Veto Lucite Rod Veto HF PMTQuartz Plate Veto Lucite Rod Veto If the readout system allows, veto counters at the back of HF can be used 11/19/200826CMS Upgrade Workshop, Nov 19-21, 2008

Charge Collection with Mini-PMTs Signal in mini PMT which is used in trigger Signal in mini PMT The mini PMT registers the signal for window hitting particles. 11/19/200827CMS Upgrade Workshop, Nov 19-21, 2008

Charge Collection with Mini-PMTs Signal in mini PMT which is used in trigger Signal in mini PMT 300 GeV Pion Beam 175 GeV Electron Beam The mini PMT registers the signal for window hitting particles. 11/19/200828CMS Upgrade Workshop, Nov 19-21, 2008

SIMULATION ACTIVITIES 11/19/200829CMS Upgrade Workshop, Nov 19-21, 2008

Simulation of “PMT Events” CMS detector simulation cannot produce “PMT events” in its current form. HF simulation is based on shower library from a stand-alone Geant4 simulation. A substantial effort is put to implement these feature to CMSSW by A. Moeller, S. Banerjee. The goal is to study the effect of “PMT events” on physics, especially for forward jets and MET. Also possible filtering algorithms are being studied and simulation will help to test these ideas. 11/19/200830CMS Upgrade Workshop, Nov 19-21, 2008

Geant4 HF Simulation in CMSSW The original HF simulation only had two depths, one for long fibers, and another for short fibers. The PMT windows were added to the simulation in the form of discs behind HF (~ 3 < η < 3.2). The hits recorded in these discs are represented by two additional depths, one for PMTs corresponding to long fibers, and another corresponding to short fibers. – There are now four total depths for HF. The simulation currently uses simplified Geant4 detector/interaction processes. GFLASH is considered to replace this approach soon. PMTs in RBXs behind HF. There are two RBXs for each HF wedge, with a total of 48 PMTs per wedge. 11/19/200831CMS Upgrade Workshop, Nov 19-21, 2008

Simulation Studies Single particles as well as simplified jets (single quark jets) are sent to the HF region to test the new simulation and filter algorithms. Next few slides show a glimpse of these studies. 11/19/200832CMS Upgrade Workshop, Nov 19-21, 2008

11/19/ Energy response, 100 GeV electrons, η=3.401 For electrons at η=3.401, the energy is closer to what is expected. The energy in depth 2 still needs improvement GeV (expected 50GeV) 10.0 GeV (expected 16 GeV) CMS Upgrade Workshop, Nov 19-21, 2008

11/19/ Energy response, 100 GeV pions, η=3.401 The energy in depths 1 and 2 is higher for pions as well. As η=3.401 is now beyond the range of the RBX, the number of hits in depths 3 and 4 has decreased GeV (expected 35 GeV) 21.5 GeV (expected 30 GeV) CMS Upgrade Workshop, Nov 19-21, 2008

11/19/ GeV P T Jets, 3.0 < η < 4.5 Events do occur in depths 3 & 4 for jets GeV 0.4 GeV CMS Upgrade Workshop, Nov 19-21, 2008

11/19/ Time of Flight (100 GeV Pions) The TOF peaks at about 53 ns for depth 1 & 2. But for depths 3 & 4, the peak is at about 47 ns. – Timing information may allow us to eliminate abnormal events. Abnormal events from TB04 arrived later that normal. CMS Upgrade Workshop, Nov 19-21, 2008

11/19/ Time of Flight (20 GeV P T Jets) The timing information for the jets is similar to that for pions, although the time is slightly later in depths 1 & 2. Using the TOF information to eliminate abnormal events appears to be a possibility. CMS Upgrade Workshop, Nov 19-21, 2008

11/19/ Timing Based Cuts GeV GeV Original With Cuts Only hits with TOF of more than 50 ns were used to reconstruct the energies. CMS Upgrade Workshop, Nov 19-21, 2008

Summary During beam tests HF is found to give “PMT Events” which are due to energetic particles hitting the PMT glass window. We proposed HF PMT system upgrade as long term solution as well as other alternatives for short term solutions. – Two channel readout per tower by using mini-PMTs or multi-anode PMTs – Scintillating crystals – Back vetoes We started to have beam tests for upgrade studies for HF at Fermilab and CERN. We are planning to continue these studies during – The crystals were tested at Fermilab and CERN and results found compatible with expectations. As a result 6 crystals were installed in CMS for LHC beam collision tests. – Mini-PMTs were tested for HF for the first time and analysis of data is currently being finalized. We plan to do more tests with 2 channel readout system in Simulation studies for CMSSW to incorporate the “PMT Events” are underway. We definitely need this to study effect of these on physics. 11/19/200839CMS Upgrade Workshop, Nov 19-21, 2008