LABORATORY GLASSWARE AND EQUIPMENT LAB 2. Welcome Welcome to the chemistry lab! Chemistry is a lot of fun, but can be even more so if you are familiar.

Slides:



Advertisements
Similar presentations
Common Chemistry Lab Equipment
Advertisements

Scientific Measurement. All measurements have a number value AND a unit.
Common Chemistry Lab Equipment. Chemistry Lab Drawer Well Plate Well Plate Used for “small scale” reactions, where you are only using drops of solutions.
Lab Equipment. Beaker: 1B Reaction vessel: wide opening allows for stirring.
Solutions, Electrolytes, and Conductivity
Due Today: Density Part 1 Pre-Lab Homework: 1. Density Part-2 Pre Lab DENSITY PART I.
Hardware Models: Limiting Reagents and Theoretical Yields Lab 4.
Measuring  Volume  Temperature  Mass. Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of.
Questions to think about… How would you describe the importance of accuracy and precision in experimentation? How is precision connected to experimental.
1 Goggles To enter the general chemistry lab, you need: Closed-toe shoes Lab manual.
Lab Equipment.
 I can identify and correctly use common lab equipment used in the chemistry laboratory.
General Chemistry I Lab Glassware and Equipment Check-In.
CHECK-IN GLASSWARE AND EQUIPMENT SURVEY OF CHEMISTRY.
General Chemistry II Glassware and Equipment Check-In.
Common Laboratory Glassware and Volumetric Glassware Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
CHM 101/102 Laboratory Manual Significant Figures and Density General Chemistry 101/102 Laboratory Manual University of North Carolina at Wilmington.
Volumetric Measurements In addition to this presentation, before coming to lab or attempting the prelab quiz you must also:  Read chapter IV in the “Laboratory.
Volume Determination and Density Lab 3. Outline Reading a meniscus Volume determination and significant digits Balances Mathematical treatment of data.
Laboratory Glassware and equipment lab 2
Laboratory Concepts Dani Klingert. Accuracy When titrating, rinse the buret with the solution to be used in the titration instead of with water. If you.
Lab Equipment General Laboratory. CENTIMETER RULER Used for measuring length or width of an object.
AN INTRODUCTION TO LABORATORY EQUIPMENT By: Ms. Buroker Scott High School.
Lab Techniques How to do a Manual Titration. Rinse the inside of the Burette Rinse the burette with 2-3 mLs of standarized NaOH solution. Make sure all.
Glassware Identification
Laboratory Equipment. Erlenmeyer Flasks Beakers.
Experimental errors.
Topic 11: Measurement and Data Processing
Preparing Solutions LG: I can use formulas for concentration to prepare standard solutions from a solid.
Experimental Procedure. Overview The supernatant from a saturated calcium hydroxide solution is titrated with a standardized hydrochloric acid solution.
Chirp! Chirp! Welcome! Instructor: Anne Yu SN 109, x74252 Lab Assistant: Jane Xu ‘12.
Titration and Buffers Chemistry Department Minneapolis Community & Technical College Intro to Chemistry Chem1020 Lab 1.
Solutions & Solubility
3.1 SIGNIFICANT FIGURES The Concepts. Significant figures pertain to MEASUREMENTS.
Making Measurements in the Lab  V Volume  Temperature  Mass Adapted from
Some Common Laboratory Glassware Please be careful when using glassware in the laboratory. Wet glassware and wet gloves are slippery. Always read a volume.
Definition Choosing a Standard Solution Making the Solution.
Measuring  Volume  Temperature  Mass. Reading the Meniscus Always read volume from the bottom of the meniscus. The meniscus is the curved surface of.
Using Laboratory Equipment Chapter 3. Laboratory Equipment  Containers and Holding Devices  Thermometers  Balances.
Reading: Chapter 2 – an informative review Chemical measurements: Tools of the trade – hardware and labs VISIT THE LAB Safety Lab notebook Introduction.
(Introduction ,The Equipment ,The Process , Calculations )
Lab 4. o Do not surf the web o Do not check your unless it’s related to this course o Do not print materials unrelated to lab o Do not connect.
Measuring  Volume  Temperature  Mass. Graduated Cylinders The glass cylinder has etched marks to indicate volumes, a pouring lip, and quite often,
I. Types of Errors: Systematic Random
LAB OVERVIEW.
Introduction The Equipment The Terms The Process Calculations
Solutions & Solubility Solution Preparation by dilution.
Unit 4 : Solutions 8.4 – Dilution and Solution Preparation.
Lab Safety General Guidelines No food or drink at any timeNo food or drink at any time Never work aloneNever work alone Follow all teacher instructionsFollow.
Lab Equipment General Laboratory. CENTIMETER RULER Used for measuring length or width of an object.
Solutions & Solubility Solution Preparation. Solution Preparation from a solid  Standard Solution = a solution for which the precise concentration is.
Volume determination and density
Plymouth North High School
 Most common for holding liquids  Hold solids or liquids that are unlikely to release gas or splatter if stirred or heated.  Beakers come in several.
Uncertainty and error in measurement
General Laboratory Techniques Dry Lab Chemistry 1105.
LABORATORY GLASSWARE AND EQUIPMENT LAB 2. Welcome Welcome to the chemistry lab! Chemistry is a lot of fun, but can be even more so if you are familiar.
LABORATORY SAFETY Keep all books, backpacks, coats, etc. off of the lab benches No eating or drinking in the lab room Wear goggles and covered shoes at.
Significant Figures Show the Uncertainty in Measured Data
Lab Equipment General Laboratory. CENTIMETER RULER Used for measuring length or width of an object.
Laboratory Glassware and equipment
Science Laboratory and Safety Equipment
Significant Figures Show the Uncertainty in Measured Data
Your Name Mr.Trimble Chemistry Period #
Reading: Chapter 2 – an informative review
Why do we have them? When we measure things, we want to measure to the place we are sure of and guess one more space.
Common Laboratory Glassware
Preparing Solutions.
Biochemistry lab. INTRODUCTION.
Presentation transcript:

LABORATORY GLASSWARE AND EQUIPMENT LAB 2

Welcome Welcome to the chemistry lab! Chemistry is a lot of fun, but can be even more so if you are familiar with the equipment you will be using in lab. Remember – whenever there’s glassware or chemicals in use, everyone has to wear goggles!

Reading a Meniscus Meniscus and Parallax

Types of Glassware Graduated glassware Volumetric (non-graduated) glassware

Graduated Glassware Beakers Use: To contain certain volumes of solutions Filtering Flasks Use: To contain certain volumes of solutions Graduated Cylinders Use: To measure out exact volumes. Burets Use: To dispense exact volumes.

Volumetric (non-graduated) Glassware Volumetric Pipets Use: To measure out exact volumes. This is the most accurate glassware in lab. Volumetric Flasks Use: To make up specified volumes and concentrations of solutions.

Reading and Recording Volumes We use significant figures to indicate the accuracy and precision of glassware. Significant figures for graduated glassware are determined differently from those of volumetric glassware.

Significant Figures: Volumetric Glassware Use the Tolerance table on p. 65 to determine glassware tolerance, unless it is printed on the glassware. For example: The 50 mL volumetric flask has a tolerance of ± 0.05 mL. Whenever you use your 50 mL volumetric flask, you will always report two zeros after the decimal, i.e mL.

Volumetric Flask When this volumetric flask is filled to the calibration mark, what volume should be reported?

Volumetric Pipet When this pipet is used to dispense solution, what volume should be reported?

Volumetric Pipet When this pipet is used to dispense solution, what volume should be reported? And to which line should the pipet be filled?

Significant Figures: Graduated Glassware 1. Look at the glassware in question. 2. Find the smallest graduation. 3. Report your volume to the closest 10% of the smallest graduation.

Reading Graduated Glassware

Smallest Graduation A. Calculate major graduation – major graduation B. Determine the number of spaces between two major graduations Smallest Graduation = A / B

Reading Beakers What volume should be reported?

Reading Beakers Smallest graduation: 10 mL 10% value: 1 mL Volume to the closest 10% of the SG: 48 mL

Reading Graduated Cylinders What volume should be reported?

Reading Graduated Cylinders Smallest graduation: 1 mL 10% value: 0.1 mL Volume to the closest 10% of the SG: 52.8 mL

Reading Burets What volume should be reported?

Reading Burets Smallest graduation: 0.1 mL 10% value: 0.01 mL Volume to the closest 10% of the SG: mL

Cleaning Glassware Each student has glassware at their individual stations. Each student is responsible for the care of their glassware. Why do we start and finish each experiment with clean glassware? Your instructor will address the appropriate ways to: Wash glassware with soap and a brush Rinse glassware with tap water Do a final rinse with very little distilled water from the distilled water faucet or from your water bottle Dry your glassware Return glassware to the APPROPRIATE drawer

Using a Digital Thermometer Carefully remove your digital thermometer from your glassware drawer. We use digital thermometers in lab to determine the temperature of solutions. Our digital thermometers can measure temperature in degrees Celsius (ºC) or degrees Fahrenheit (ºF). Eventually you should be able to interconvert between these two scales. Kelvin will also be addressed in class. Your instructor will point out all major features of this unit.

Glassware The use of many pieces of glassware is intuitive. You will not be shown how to use a beaker, graduated cylinder, medicine dropper, or filtering flask. Other pieces of glassware are highly specialized. You will now be shown how to properly prepare and utilize the following pieces of glassware: Analytical balance Buret Volumetric flask Volumetric pipet

Experimental Procedure and Report Follow the instructions starting on page 72. Record your responses starting on page 85. Do not leave the lab until you have followed all of the instructions under Part 7.

Next Assignment: Lab 3 Read the required reading sections in your textbook and lab manual. Complete and submit your pre-lab questions by the deadline. Remember to study for your next quiz. Submit the Lab 2 report at the start of the next lab.

Lab 4 Pre-lab Questions This pre-lab will take a while to complete, start early. Read the lab write-up in your manual (pp ). Complete the pre-lab questions (pp ) in MicroLab™ in the SCICom lab (NSB 204), Chemistry Resource Center (CPSB 302K) or on your personal computer if you download the program. The program may be downloaded from under the Downloads link. Take this exercise seriously. You will be required to complete a similar exercise in lab in 2 weeks without help from your lab manual.