The SIMATIC S7 System Family

Slides:



Advertisements
Similar presentations
SIMATIC® S7系统家族 SIMATIC® PCS 7 NET Software HMI PC SIMATIC® WinCC DP
Advertisements

Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.
Whats Inside a PC?. UNT in partnership with TEA, Copyright © All rights reserved.2 II. Major Components: Motherboard 1. Referred to as heart of.
SIMATIC ET 200M / MP Systemredundancy
Automation and Drives WinAC – the SIMATIC S7 in your PC News Q1/2004.
Electrical distribution for ALICE experiment & Electronic Rack Control S. Philippin.
Automation and Drives Applications with IE/PB Link  Verticale integration using engineering tools like SIMATIC PDM or Drive ES  Remote diagnostic / remote.
Windows DX 66 megahertz (MHz) or faster processor (Pentium central processing unit recommended). 16 megabytes (MB) of memory (24 MB recommended).
PADS Professional Overview. PADS Professional A bundle of easy-to-use software applications for professional digital signage in any environment. This.
Analog Value Processing
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
SIMATIC S
Computer Terminology … Remember: Knowledge is Power!
Lesson 5-Accessing Networks. Overview Introduction to Windows XP Professional. Introduction to Novell Client. Introduction to Red Hat Linux workstation.
Date: File:MC-SMO-SYS_10.1 SIMOTION Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Connecting HMI Systems.
Automation and Drives SINUMERIK SYSTEM OVERVIEW: GENERAL INFORMATION © SIEMENS AG 2003 SINUMERIK SYSTEM OVERVIEW: General information.
Setup Guide - Profibus communication AC141x with Step 7 V5.5 English
PROFIBUS "Ready for anything!".
By: Andri Kuncoro. SIMATIC Overview SIMATIC Controller (PLC) S7-200 S7-300 S7-400.
and other courses on PCS7, IT, NC ....
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 DCN MPCC PO MPC Multi PC’s  High Performance PC’s  Microsoft Windows® NT 4.0, 2000.
SIMATIC S7 Software Redundancy
Date: File:PRO1_02E.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation The SIMATIC Manager.
Date: File:ST-PCS7SYS_V6_üb_pro_E.1 SIMATIC PCS 7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Configuration.
Automation and Drives PC- based Control All about SIMATIC WinAC.
Computer Basics An overview of computer hardware ICT Tools: Computer Basics.
11 INSTALLING WINDOWS XP PROFESSIONAL Chapter 2. Chapter 2: INSTALLING WINDOWS XP PROFESSIONAL2 OVERVIEW  Install Windows XP Professional  Upgrade from.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
B.A. (Mahayana Studies) Introduction to Computer Science November March The Motherboard A look at the brains of the computer, the.
Automation and Drives Siemens Automation Cooperates with Education A&D AS SM GE /2006, Page 1 © Siemens AG Subject to change Trainer Package.
Organization of a computer: The motherboard and its components.
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
The "DCS in a Box" SIMATIC PCS 7 BOX
Translate the following message:
Infinity-project.org The Institute for Engineering Education Engineering Education for today’s classroom. 1 Infinity Project Laboratory Setup.
SIMATIC Overview Automation and Drives SIMATIC Industrial Automation System.
SoftPLC In TealwareTM SoftPLC ProcessorsTM Hardbook SoftPLC’s
Date: File:PRO1_12E.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation Troubleshooting.
Date: File:PRO1_01C.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation SIMATIC S7 系统家族.
Schutzvermerk nach DIN 34 beachten XControl XC600 The modular, open industry control with IT functionality by Moeller XControl.
1 1 ► Catalog ► Manual ► Installation Guide ► Troubleshooting ► Purchase Order Copyright (c) 2007 IDTECK. All rights reserved. e-Training Center STARWATCH.
Communication via MPI Contents Page Networking via MPI ………………
ALARM APPLICATIONS.  DS200 Alarm Interface is an infrastructre, which provides a platform to program DS200 system via one central point or collect the.
Integra32 System - Training Course
Date: File:PRO1_18E.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation Appendix: Technical.
Date: File:PRO1_04E.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation Hardware Configuration.
 Hardware compatibility means that software will run properly on the computer in which it is installed.  When purchasing software, look for one of these.
Lesson 2 Installation and Upgrade Operating System Fundamentals.
Center of Competence WinCC, PCS7 Siemens AG Industrial Solution and Services D Mannheim © Siemens AG 2007 Subject to change without prior notice.
Binary Operations I0.0 I0.1 Q 8.0 Q 8.1 I 1.0 ( MCR< ) (MCRA) Q 8.0
 System Requirements are the prerequisites needed in order for a software or any other resources to execute efficiently.  Most software defines two.
Družina Simatic. LOGO! Soft Comfort za krmilnike LOGO! STEP 7-Micro/WIN za krmilnike S7-200 STEP 7 za krmilnike S7-300 in S7-400 Programska oprema krmilnikov.
SIMATIC® S7系统家族 SIMATIC® PCS 7 NET Software HMI PC SIMATIC® WinCC DP
Automation and Drives A&D AS SM6, Page 1 SIMATIC S7-300 Workshop to promote the S7-300 automation platform.
What is this The Processor Think of the processor as the brain of the computer. The processor speed is an indicator of how fast the brain can make.
PCs ENVIRONMENT and PERIPHERALS Lecture 4. An expansion cards: - An expansion card (expansion board) is an electronic circuit board that adds more functionality.
Copyright © 2006 by The McGraw-Hill Companies, Inc. All rights reserved. McGraw-Hill Technology Education Chapter 1 Looking Inside the Computer System.
Organization Blocks Operating system OB1 FC FB FB FC SFC SFB OBs Other
Programmable Logic Controller (PLC) - Hardware and Software Lecture 12.
Date: File:TrainingUnits.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation 培训设备 V.
Identify internal hardware devices (e. g
DIT314 ~ Client Operating System & Administration
2500 Series® Compact System Components
SIMATIC S
2500 Series® Compact System Components
ProDaS Process Data Recorder.
2500 Series® Compact System Components
Computer Repair & Maintenance
Chapter 2 – PLC Hardware Components
Project Migration / Management
Presentation transcript:

The SIMATIC S7 System Family WinCC PC DP Controller HMI NET PCS 7 Software SIMATIC Contents Page SIMATIC Overview .............................................................................................................................. 2 S7-200 ................................................................................................................................................. 3 S7-200: Modules ........................................................................................................................... 4 S7-200: CPU Design .......................................................................................................................... 5 S7-300 ................................................................................................................................................. 6 S7-300: Modules ........................................................................................................................... 7 S7-300: CPU Design .......................................................................................................................... 8 S7-400 ................................................................................................................................................. 9 S7-400: Modules ........................................................................................................................... 10 S7-400: CPU Design (Part 1) .............................................................................................................. 11 S7-400: CPU Design (Part 2) .............................................................................................................. 12 Programming Devices........................................................................................................................... 13 PG/PC Requirements for Installing STEP 7 ………........................................................................... 14 Installing the STEP 7 Software ........................................................................................................... 15 Result of Installation ...................................................................................................................... 16

SIMATIC Overview SIMATIC HMI SIMATIC PG SIMATIC PC SIMATIC NET SIMATIC 7 8 9 4 5 6 1 2 3 . D E F A B C I N S L H T P R K M O SIMATIC HMI SIMATIC PG SIMATIC PC SIMATIC NET PROFIBUS-DP Industrial Ethernet PROFIBUS MPI - Network SIMATIC Controller Introduction The introduction of electronics has resulted in great changes in industrial control engineering. Together with automated machinery, whose application possibilities were expanded through electronic controls, these changes have also led to new technologies and branches. Controllers In addition to the energy supply, control elements are required for the operation of machines and processes in almost all areas of manufacturing. It must be possible to initiate, control and monitor the operation of any given machine or process. In the past, control tasks were solved with conventional control technology by individually - that is, dependent on the task - wiring contacts and relays. Today programmable logic controls are largely used to solve automation tasks. Totally Integrated In order for companies to remain competitive, it is not enough to isolatedly Automation automate only individual processing stations or machines. The demand for more flexibility with higher productivity can only then be fulfilled when the individual machines are integrated in the entire system. The information flow between all components is essential for the functioning of the entire system. Production processes are no longer seen as individual partial processes, but rather as integral components of an entire production process. Also, the entire process is also no longer structured centrally as hierarchical. Now the process is structured as distributed and autonomous individual elements. The total integration of the entire automation environment is today made possible with the help of: • common configuring and programming of individual partial systems • common data management • common communication between all participating automation components. ASI FM SV SIMATIC DP

S7-200 EM 221 DI 8 x DC24V I.0 I.1 I.2 I.3 I.4 I.5 I.6 I.7 Features • Modular small control system for the lowest performance range, • Performance-graded range of CPUs, • Extensive selection of modules, • Expandable with up to 7 modules, • Backplane bus integrated in the modules, • Can be networked with - RS 485 communication interface or - PROFIBUS, • Central PG connection with access to all modules, • No slot restrictions, • Own software, • “Total Package” with power supply, CPU, I/O in one unit, • "Micro PLC" with integrated functions.

S7-200: Modules EM CP EM CP242 - 2 Expansion • Digital input modules: Modules (EM) - 24V DC - 120/230V AC • Digital output modules: - 24V DC - Relais • Analog input modules: - Voltage - Current - Resistance - Thermocouple • Analog output modules: Communications The CP 242-2 can be used to connect the S7-200 as Master to an AS-Interface. Processors (CP) As a result, up to 248 binary elements can be controlled via 31 AS-Interface Slaves. This significantly increases the number of inputs and outputs for the S7-200. Accessories Bus connector EM

S7-200: CPU Design Outputs Memory Card Mode Selector Potentiometer Mode Selector For manual mode selection: STOP = Stop mode; the program is not executed. TERM = Program execution, read/write access possible from PG. RUN = Program execution, read-only access possible from PG. Status Indicators SF = Group error; internal CPU error (LEDs) RUN = Run mode; green STOP = Stop mode; yellow DP = Distributed I/O ( only CPU 215) Memory Card Slot for memory card. A memory card saves the program contents in the event of a power outage without the need for a battery. PPI Connection The programming device / text display or another CPU is connected here. Status Indicators Status Indicators for integrated DI/DO PPI Connection Inputs

S7-300 Features • Modular small control system for the lowest performance range • Performance-graded range of CPUs • Extensive selection of modules • Expandable with up to 32 modules • Backplane bus integrated in the modules • Can be networked with - Multipoint interface (MPI), - PROFIBUS or - Industrial Ethernet. • Central PG connection with access to all modules • No slot restrictions • Configuration and parameter setting with the help of the "HWConfig“ tool.

S7-300: Modules CPU IM (optional) SM: DI SM: DO SM: AI SM: AO FM: - Couting - Positioning - Closed-loop control CP: - Point-to-Point - PROFIBUS - Industrial Ethernet PS (optional) Signal Modules • Digital input modules: 24V DC, 120/230V AC (SM) • Digital output modules: 24V DC, Relay • Analog input modules: Voltage, current, resistance, thermocouple • Analog output modules: Voltage, current Interface Modules The IM360/IM361 and IM365 make multi-tier configurations possible. (IM) They loop the bus through from one tier to the next. Dummy Modules The DM 370 dummy module reserves a slot for a signal module whose parameters (DM) have not yet been assigned. It can also be used, for example, to reserve a slot for installation of an interface module at a later date. Function Modules Perform “special functions": (FM) - Counting - Positioning - Closed-loop control. Communication Provide the following networking facilities: Processors (CP) - Point-to-Point connections - PROFIBUS - Industrial Ethernet. Accessories Bus connectors and front connectors

S7-300: CPU Design SIMATIC S7-300 SIMATIC S7-300 SIEMENS SIEMENS SF BATF DC5V FRCE RUN STOP RUN-P M RES SIMATIC S7-300 Batterie MPI SIEMENS CPU315-2 DP SF BATF DC5V FRCE RUN STOP SF DP BUSF RUN-P RUN STOP M RES SIMATIC S7-300 Batterie MPI DP Mode Selector MRES = Modul Reset function STOP = Stop mode; the program is not executed. RUN = Program execution, read-only access possible from PG. RUN-P = Program execution, read/write access possible from PG. Status Indicators SF = Group error; internal CPU fault or fault in module with diagnostics (LEDs) capability. BATF = Battery fault; Battery empty or non-existent. DC5V = Internal 5 V DC voltage indicator. FRCE = FORCE; indicates that at least one input or output is forced. RUN = Flashes when the CPU is starting up, shows a steady light in Run mode. STOP = Shows a steady light in Stop mode. Flashes slowly for a memory reset request, Flashes quickly when a memory reset is being carried out, Flashes slowly when a memory reset is necessary because a memory card has been inserted. Memory Card A slot is provided for a memory card. The memory card saves the program contents in the event of a power outage without the need for a battery. Battery Compartment There is a receptacle for a lithium battery under the cover. The battery provides backup power to save the contents of the RAM in the event of a power outage. MPI Connection Connection for a programming device or other device with an MPI interface. DP Interface Interface for direct connection of distributed I/Os to the CPU.

S7-400 Features • The Power PLC for the mid to upper performance range, • Performance-graded range of CPUs, • Extensive selection of modules, • Can be expanded by over 300 modules, • Backplane bus integrated in the modules, • Can be networked with - Multipoint interface (MPI), - PROFIBUS or - Industrial Ethernet, • Central PG connection with access to all modules, • No slot restrictions, • Configuration and parameter setting with the help of the "HWConfig“ tool, • Multicomputing (up to 4 CPUs can be used in the central rack ).

S7-400: Modules CPU SM: DI SM: DO SM: AI SM: AO CP FM SM IM PS Signal Modules • Digital input modules: 24V DC, 120/230V AC (SM) • Digital output modules: 24V DC, Relay • Analog input modules: Voltage, current, resistance, thermocouple • Analog output modules: Voltage, current. Interface Modules The IM460, IM461, IM463, IM467 interface modules provide the connection (IM) between various racks: • UR1 (Universal Rack) with up to 18 modules • UR2 (Universal Rack) with up to 9 modules • ER1 (Extension Rack) with up to 18 modules • ER2 (Extension Rack) with up to 9 modules. Function Modules Perform “special functions": (FM) • Counting • Positioning • Closed-loop control. Communication Provide the following networking facilities: Processors (CP) • Point-to-Point connections • PROFIBUS • Industrial Ethernet. PS

S7-400: CPU Design (Part 1) Start-up Type Switch Mode Selector Mode Selector MRES = Modul RESet STOP = STOP mode, i.e. no program execution and output disabled ( "OD“ mode= Output Disabled). RUN = Program execution, read-only access possible from PG. RUN-P = Program execution, read/write access possible from PG. Start-up Type Switch CRST = When you start the CPU with the mode selector STOP / RUN, a “complete restart" is performed (Cold ReSTart). WRST = When you start the CPU with the mode selector STOP / RUN, a “restart" is performed (Warm ReSTart) The CPU requests the start-up type via the Status LED (selectable with the CRST/WRST switch). e.g. CPU412-1 e.g. CPU416-2DP * for further CPUs please see catalog

External battery supply S7-400: CPU Design (Part 2) Fault LEDs for general CPU faults Fault LEDs for integrated DP interface DP interface Slot for Memory Card MPI interface EXT-BATT Additional external battery voltage supply (DC 5...15V to backup the RAM, e.g. when the power supply is being replaced). MPI Connection For the programming device or another device with MPI interface. DP Interface The 413-2DP, 414-2DP, 416-2DP and 417-2DP CPUs have an integrated DP interface for direct connection of distributed I/Os to the CPU. Slot for In the S7-400 CPUs you can, depending on your requirements, insert RAM or Memory Cards Flash EPROM cards as external load memory: • RAM cards with a capacity of: 64KByte, 256KByte, 1MByte, 2MByte. The contents are backed up via the CPU battery. • Flash EPROM cards with a capacity of: 64KByte, 256KByte, 1MByte, 2MByte, 4MByte, 8MByte, 16MByte. The contents are backed up on the integrated EEPROMs. External battery supply

Programming Devices PG760 PG740 PG720 PG 720 is an industry-standard programming device, powerful and easy to use, especially for maintenance and service, but also for programming and configuration - the ideal tool for shopfloor applications. Features: • Measurements in Notebook format, • Independent of power supply, • AT-compatible, • Powerful hardware, • Equipped with all necessary SIMATIC interface ports. PG 740 is a portable programming device, ideal for all applications in an automation project, as well as being an extremely powerful, industry-standard PC. Features: • High-level system performance, • Excellent expansion facilities, • TFT- Farbdisplay, • Highly rugged design, • Equipped with all the necessary SIMATIC interface ports. PG 760 is a multi-functional desktop programming device for all configuring and programming tasks in the engineering office. Its high-level system performance, flexible expansion capability and comprehensive facilities make it the ideal office tool for all automation projects. Note A hand-held programming device is also available for programming the S7-200 in STL (PG702 = approx. 230 grams, 144 x 72 x 27mm, 2 x 20-character LC display). PG720

PG/PC Requirements for Installing STEP 7 Hardware/Software Requirements • Processor 80 486 or higher, Pentium recommended • Hard Disk (free) Min. 300 MB (for Windows, Swap File, STEP7, Projects) • RAM >= 32 MB, 64 MB recommended • Interfaces CP 5611 or MPI card or PC-Adapter Programming Adapter for Memory Card • Mouse Yes • Operating System Windows 95/98/NT Requirements New PGs of the SIMATIC S7 series provide the optimum conditions for the STEP 7 software. An MPI card can be installed in PCs which meet the requirements listed above, or they can be connected to the COM interface with the PC-Adapter. MPI Multi-Point Interface.

Installing the STEP 7 Software or Installation 1. Activate “Setup.exe” by selecting “Add/Remove Programs” in the “Win95- >Control Panel”. 2. Choose Options. 3. Choose Language. 4. Authorization disk when prompted. 5. Re-boot when prompted. Notes: 1. As of STEP 7 V4.0, the software is only available on CD-ROM. 2. Software Service Packs can also be downloaded from the Internet. Software Protection The STEP 7 software is copy-protected and can only be used on one programming device at a time. When you have installed the software, you cannot start using it until you have transferred the authorization to the hard disk from the authorization disk. Note As of STEP 7 V5.0, the software can also be started without authorization. After a specific time period has run out, the user will be requested to install an authorization. Be sure to read the notes in the README.TXT file on the authorizaiton disk. If you do not observe these instructions, you risk losing your authorization. Service Packs Free-of-Charge Software Service Packs can be downloaded from the Internet via http://www.ad.siemens.de/simatic-cs.

Result of Installation Double-click on Icon Introduction The main tool in STEP 7 is the SIMATIC Manager. There are two ways in which to activate it: 1. via Task bar -> Start -> SIMATIC -> STEP7 -> SIMATIC Manager 2. via the icon "SIMATIC Manager“. Activate via Start menu