Shortwave Diathermy Clinical Application. Treatment Dosages Pulse DoseSensationWidthRate (pps) NTNo warmth65 µsec100 – 200 1Mild warmth100 µsec800 2Moderate.

Slides:



Advertisements
Similar presentations
Therapeutic Ultrasound
Advertisements

F&T Inc. OVERHEAD CRANE SAFETY.
Shortwave and Microwave Diathermy
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
AUTOMATED EXTERNAL DEFIBRILLATION
1 Burns Pakistan ICITAP. Learning Objectives Understand different types of burns Learn to identify degrees of burns Know First Aid treatment for burns.
1 Module 9: Microscope Maintenance. 2 Learning Objectives Learning Objectives At the end of this module, you will be able to Store the microscope properly.
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
Last revised March 19, 2015 Electrical Department – EQUAL CODE: EL304 Care, Use, and Maintenance of Rubber Insulating Gloves.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Shortwave Diathermy Prof. Dr. Gehan Mosaad.
Shortwave and Microwave Diathermy part(2). Induction Electrodes (Drum Electrode) One Or More Monopolar Coils Rigidly Fixed In A Housing Unit May Use More.
Safety in the Chemistry Laboratory. What we have to learn to do, we learn by doing. -Aristotle.
Better Safe Than Sorry A WORLD THAT STARTS WITH ELECTRICAL HAZARDS AND SAFETY. ELECTRICITY IS A VERY SERIOUS BUSINESS AND THE EFFECTS ON THE HUMAN, ELECTRICAL.
Shortwave Diathermy ESAT 3640 Therapeutic Modalities.
EDEXCEL L EVEL 3 SUBSIDIARY DIPLOMA IN B EAUTY T HERAPY Infra-red Lesson.
© 2005 – FA Davis, Inc. Compression Devices. © 2005 – FA Davis, Inc. Purposes Edema reduction –Improves healing environment –Reduces neuromuscular inhibition.
Burns PAGES LEQ: HOW DOES THE TYPE OF BURN DETERMINE THE TYPE OF TREATMENT PROVIDED?
AccuMax Multi-Point Injection Mechanics
By: Bobby Sciarrone, Matt Mantilla Eddy Quevedo
KITCHEN SAFETY PREVENTING HAZARDS IN THE KITCHEN
Shortwave Diathermy Chapter 9.
Safety Guidelines General Information Always get your TEACHER’S permission before beginning a Lab. Read the Lab before starting Look up unknown safety.
Safety in the Workplace
Soft tissue injuries Chapter layers of the skin 1. Epidermis-outer layer that is a barrier to infection ”Superficial” 2. Dermis- middle layer that.
Electrical Safety.
Laboratory Safety Rules Page 1068 Appendix B In your textbook.
Do this now… Go to and complete the pre-lesson survey. Go to my eBoard and set up.
INTRODUCTION Microwave diathermy الميكروويف إنفاذ حراري(MWD), is a form of electromagnetic radiations lying between shortwave and infrared waves. Where.
Compression Devices. © FA Davis Purposes Edema reduction Improves healing environment Improves healing environment Reduces neuromuscular inhibition.
Copyright  Progressive Business Publications Electrical Safety.
Shortwave Diathermy Chapter 9.
Therapeutic Ultrasound
Shortwave and Microwave Diathermy
© 2005 – FA Davis Shortwave Diathermy Clinical Application.
Lab Safety. Science is a hands-on laboratory class Safety is the #1 priority Rules to follow at all times Safety Contract to read and sign before laboratory.
Burns By: Vera Ware.
Microwave Diathermy Mohammed Taher Ahmed Ph.D PT, Rehabilitation Health Science College of Applied Medical Science.
Electrical Stimulation Treatment Strategies. HVPS: Neuromuscular Stimulation Output Intensity Strong, intense, comfortable contractions. Pulse frequency.
Shortwave.
Electrical Stimulation Basic Setup and Patient Preparation Read and Follow the Manufacturer’s Recommendations.
Soft tissue injuries Chapter layers of the skin 1. Epidermis-outer layer that is a barrier to infection 2. Dermis- middle layer that contains nerves.
Horticulture II - Landscape UNIT C LANDSCAPE INSTALLATION AND MAINTENANCE.
GENERAL PRINCIPLE OF INSTRUMENTATION. INTENDED LEARNING OBJECTIVES Accessibility Visibility, illumination and retraction Condition of instruments Maintaining.
Please take out a piece of paper… What lab safety rules do you already know? (Must have at least 7 bullets)
Ultrasound 10cm 2 Ultrasound (US) Therapeutic ultrasound –Uses acoustic energy, delivered at high frequencies for therapeutic purposes Electrical current.
Shortwave and Microwave Diathermy Chapter 10. Diathermy Application of High-Frequency Electromagnetic Energy Used To Generate Heat In Body Tissues Heat.
Safety in the Science Lab!!
Power Tool Safety Don’t operate a machine until: A) receiving proper instruction B) you fully understand how to use it C) you have permission Always wear.
Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 3 General Application Procedures.
Burns -are injuries to the skin, soft tissue, and bone - destroys top, middle, and bottom layers of skin.
SAFE USE OF DIATHERMY RACHEAL AFOLABI, RN, RM, H. Dip. PERI-OPERATIVE NURSING, H.Dip. HEALTH SYSTEM MANAGEMENT.
Lab Safety General Guidelines. Conduct yourself responsibly –Follow written and verbal instructions –Never work alone –Don’t touch any equipment, chemicals.
HYDROCOLLATOR Sekar.L INTRODUCTION  The use of moist heat as a therapeutic agent is one of the oldest forms of medicine.  Commercial hot packs is one.
Microwave diathermy.
DIATHERMY Diathermy was once one of the most popular modalities used in rehab. Became less popular with development of more modern tech like US and because.
Placement of applicator
14 Refrigerant Recovery, Recycling, and Recharging.
Deep Heat Ultrasound & Diathermy
Chapter 2. General Application Procedures
AED Chapter 3.
Clinical engineering Lecture (7).
LIFEPAK® 1000 Defibrillator Orientation Guide
Iontophoresis Vineela.U 08B21A0538 CSE.
Shortwave Diathermy By Ms.B. Nelson.
Cashew Dryer User Manual
F&T Inc. OVERHEAD CRANE SAFETY.
Application of IRR Before application (preparation for patient of IRR treatment) Equipments required :- Preparation of equipment (IRR) Application of IRR.
Diathermy Presented by: Hesamoddin Bagheri Supervisor: Dr. Salamat.
Chapter 2. General Application Procedures
Presentation transcript:

Shortwave Diathermy Clinical Application

Treatment Dosages Pulse DoseSensationWidthRate (pps) NTNo warmth65 µsec100 – 200 1Mild warmth100 µsec800 2Moderate warmth200 µsec800 3Vigorous warmth 400 µsec800

Pulsed SWD Setup ParameterSetting Output mode:Pulsed Bursts per sec:800 Burst duration:400 sec Interburst850 sec interval Output intensity150 W RMS 48 W/burst RMS RMS = Root Mean Squared

Set-up and Application

Treatment Duration Nonthermal, Mild, and Moderate Heating Duration – 20 to 30 minutes Repeated as needed Two weeks Vigorous Heating Duration – 15 minutes Applied every other day

Precautions Remove contact lenses when applying SWD around the head, face, or eyes. Cover the skin with at least 0.5 inch of toweling Do not allow perspiration to collect in the treatment field. Thick adipose tissue in the treatment area can result in overheating. Never allow the skin to come into contact with the heating unit or cables. If the cable method is used, do not allow them to touch each other. If electrode pads are used, space them at least the distance of their diameter apart. A deep, aching sensation may be a symptom of overheating the tissues. Overheating of the patient’s tissues may cause tissue damage without any immediate signs. The SWD energy scatters 2 to 3 feet from the source –A distance of 3 feet from the source of the energy should be maintained to ensure the operator’s safety.

Instrumentation Master Power Switch: Turns the unit on. Output Intensity (Power): Adjusts the amount of energy delivered to the patient. Patient Interrupt Switch (Safety Switch): Allows the patient to end the treatment. Pause: Interrupts the treatment to allow repositioning of the patient, etc.

Instrumentation (Cont.) Pulse Rate (Pulse Frequency): Sets the number of pulses per second (PPS) for the output. Start/Stop: Initiates or terminates the treatment. Treatment Timer: Sets the treatment duration. Tuning: Adjusts the output resonance to match the patient’s tissues. –Some units will shut off if an out of tune state is detected –Most contemporary units are self-tuning

Patient Preparation Ensure the absence of all contraindications. Remove all jewelry, clothing, coins, and other metallic items from the patient. For personal safety, remove your rings, watches, bracelets, etc. No metal can be within the immediate treatment area Keep the patient out of reach of any metal objects that can serve as a ground (e.g., outlets, pipes). Clean and dry the body part. Water, skin oils, etc. can increase superficial heat production.

Patient Preparation (Cont.) Position the patient in the most appropriate manner for the body area being treated. To encourage venous return, elevate the treated extremity. To prevent burns cover the area with a dry terry cloth towel: –This provides spacing between the source of the shortwave diathermy –Absorbs perspiration –A portion of the treatment area must remain visible to check for burns during the treatment.. Explain to the patient that mild warmth should be felt. Instruct the patient to inform you if any unusual sensations are experienced.

Patient/Generator Tuning If the unit must be manually tuned: Position the electrodes over the patient. Increase the output intensity to appx. 40% of the max. Adjust the TUNING control until the output meter reaches its peak… … then decrease the TUNING to the patient’s comfort. A unit is tuned when less than half of the maximum output is used. –Some units will automatically shut off if more than 50 percent of the maximum output is used. If this occurs, the unit must be tuned again.

Initiation of the Treatment Drum Method Turn the unit on; allow it to warm up if necessary. Some units must be tuned to allow for maximal energy transfer. If indicated by the manufacturer’s instructions, place a folded towel between the body part and the drum. Position the drum approximately 0.5 to 1 in. above the toweling. The surface of the drum must be parallel to the skin surface being treated, otherwise the skin closest to the drum will overheat (the Cosine Law)

Initiation of the Treatment (Cont.) Instruct the patient not to move until the unit is shut off. Set the TIMER to the desired treatment duration. Increase the intensity until the patient feels mild warmth. If the drum must be moved or if it becomes necessary to dry the area, return the intensity to zero before making any adjustments. Do not leave the patient left unattended Regularly check the skin for signs of burns and inquire about unusual sensations. –Adjust the INTENSITY, PULSE RATE, and/or electrode placement as necessary.

Termination of the Treatment After the treatment, return the intensity to “zero” and shut off the unit. Inspect the skin for signs of burns or other abnormal treatment outcomes. Record the treatment parameters in the patient’s file.

Maintenance Daily Maintenance Clean the face of the drum or cables using a manufacturer-approved cleanser. Regular Maintenance Inspect electrical cords for kinks and frays. Annually The unit must be serviced and calibrated by a qualified service technician.