WalkOn Reactionplus.

Slides:



Advertisements
Similar presentations
Effects of different shoe-lacing patterns on the biomechanics of running shoes Journal of Sports Sciences Feb2009, Vol. 27 Issue 3, p267 9p. Authors: Marco.
Advertisements

Lower limb orthosis Lower limb orthosis.
Enhancing the Health of the Everyday Athlete – Efficient Barefoot Movement Stephen Gangemi, DC, DIBAK.
Prosthetic Gait Deviations
Ankle-Foot Orthoses (AFOs)
Basic Anatomy of Musculoskeletal System
Orthomerica ® Products, Inc. partnering with Insert Your Name Here.
Biomechanical Examination Parameters
ASSESSMENT CHAPTER 6. Physical assessment PHYSIOTHERAPY ASSESSMENT session CHAPTER 6 PART
Achilles & Ankle Injuries Achilles Tear and Ankle Sprain.
Kinesiology of the musculoskeletal system
17/07/1436RHS 4221 Dr. Afaf A.M Shaheen Lecture 4 RHS 422.
ESS 303 – Biomechanics Ankle and Foot. Tibiofibular Joint Similar to radioulnar joint Superior tibiofibular joint Middle tibiofibular joint (interosseus.
TARSALS, METATARSALS & PHALANGES
The Brio Unique to ENDOLITE
Examination of Ankle & Foot NOORA ALAMMADI. First we have to: LOOK FEEL MOVE.
The Ankle.
Muscle and Joint Tests for Lower Extremity Ankle Joint and Foot Group 6 Kevin, Jonathan, Heather, Sybil, Andrew, and Chris.
Muscular System.
Primary functions of running shoes -Reduce high pressure areas -Reduce excessive rearfoot pronation -Reduce impact forces -Reduce take-off supination of.
Running and Court Shoes n Assignments: -Read Ch 2 of Kreighbaum & Smith -Submit 2 questions from readings for discussion n Primary functions of running.
Arches of the Foot Insoles as Treatment March 23, 2015.
The Ankle and Foot. STRUCTURE AND FUNCTION OF THE ANKLE AND FOOT Bones of the ankle The distal tibia and fibula 7 tarsal 5 metatarsals 14 phalanges.
Ankle Anatomy Review Mr. Brewer. Terminology Distal – Further away from the core of the body. Proximal – Closer to the core of the body. Lateral- Away.
Muscular System.
Upper Extremities Parts  Shoulder Girdle  Shoulder Joint  Elbow Joint  Radioulnar Joint  Wrist Joint.
Daryl Harkin – Basketball Shoe
Ms. Bowman. 26 bones Phalanges-toes; proximal, middle, and distal Metatarsals-5; between phalanges and tarsals Tarsals-calcaneus, talus, navicular, cuboid,
The dancer in training The Foot.
Rehabilitation after ankle sprain Dr. Ali Abd El-Monsif Thabet.
Choosing the Correct Shoe
Terminology 101.
Body Organization Review
Anatomical Terms of Motion
The Navigator Foot. PRODUCT The NAVIGATOR is a multi-axial unit with integral spherical ankle Resilient Keel The package has a foot shell and proximal.
Skeletal and muscular considerations in movement Knee, Ankle, & Foot.
THE FOOT Chapter 18.
ANKLE JOINT Bony arrangement = stability
Manual Muscle Testing An evaluation system for diagnosis of disease or dysfunction of the musculo- skeletal and nervous systems.
The right foot forward, or the right shoe?
Complete the handout on anatomical planes, axes and position
Global Launch Presentation
Chapter 5 The Ankle and Lower Leg. Clinical Anatomy  VERY IMPORTANT! Pages  Bones and bony landmarks  Articulations and ligamentous support.
Introduced By You Friend: Amal Abd-Almunem
Bowler’s Comfort An Advanced, State of the Art Comfort Orthopedic Bowler’s Shoe.
© McGraw-Hill Higher Education. All Rights Reserved Chapter Five.
FOOT & ANKLE.
Foot and Ankle Injuries
Muscle Movements, Names and Types Ch 6 Anatomy and Physiology.
PERIPHERAL Joint Mobilization
Active Ankle-Foot Orthotic Air Muscle Tethered Team P13001 Nathan Couper, ME Bob Day, ME Patrick Renahan, IE Patrick Streeter, ME This material is based.
2) Knee.
Copyright © F.A. Davis Company Part IV: Exercise Interventions by Body Region Chapter 22 The Ankle and Foot.
Figure Figure Figure Figure
Your Personal Shoe Guide. Poorly fitted shoes cause pain and suffering. Good feet are attractive. Dirty, sick and filthy feet are unsightly and can disgust.
Anatomical Terminology
Running Gait.
CHAPTER 11 Ankle and Foot.
Muscle Movements.
Muscular System.
Planes of Movement Anatomical Terms
Anatomy and Physiology
ERGOnomics TECHnologies
Joints (Articulations).
THE ANKLE AND THE FOOT Structure
Movements Flexion Extension Hyperextension Adduction Abduction
The Muscular System Movements
بكلوريوس طب وجراحة عامة/بورد علم الامراض
t e c h n o Curling Shoe Innovations
Movement of the Joints.
Presentation transcript:

WalkOn Reactionplus

Agenda Differentiation in the WalkOn Range Indications Product description Sizing & Scope of delivery Spare parts Product information WalkOn Reactionplus vs. key competitor Durability and quality testing WalkOn Reactionplus Global Launch Presentation | NEO

1. Differentiation in the WalkOn Range -Mild weakness knee extensors 2-4 –Higher knee extension moment -Higher forefoot energy restoring WalkOn Reactionplus -Plantar flexors weakness 0-4 -Mild weakness knee extensors (fatigue) 3-5 -Knee instability valgus/varus -High energy restoring 28U25 WalkOn Reaction 28U24 -Plantar flexors weakness 3-5 -Normal knee extensors -Energy restoring -Low Knee instability valgus/varus WalkOn Trimable 28U11/23 -Normal plantar flexors -Normal knee extensors -Low energy restoring -stable knee joint AB 28U22 WalkOn Flex Normal Ankle stability Low Ankle Stability Dropfoot WalkOn Reactionplus Global Launch Presentation | NEO

2. WalkOn Reactionplus Indication Higher stability and influence of the knee joint! Indication Weakness of the dorsal extensors/ weakness of the plantarflexors, max. mild spasticity, e.g after stroke, traumatic brain injury, MS, neuromuscular atrophy, or peroneal paralysis. Mild weakness and /or fatigue of knee extensor muscles. AB WalkOn Reactionplus Global Launch Presentation | NEO

2. WalkOn Reactionplus Indication Mode of action The different anterior shell design with the medial strut connection to the foot offers more control in the sagittal and frontal plane and allows certain knee influence AB sagittal frontal WalkOn Reactionplus Global Launch Presentation | NEO

3. General product description WalkOn Reaction vs. WalkOn Reactionplus The main differences Stiffer carbon fiber spring Dyneema protection as differentiation Higher forefoot resistance WalkOn Reactionplus Global Launch Presentation | NEO

3. General product description Mode of action WalkOn Reaction liner (Cover) made of climate regulating material Outlast for high wearer comfort and less perspiration Anterior shell with anatomical, asymmetric shape for easy donning/doffing Unique medial carbon fibre strut in a special spring design for high energy restoration and near-anatomical centre of rotation, reinforced with Dyneema AB The structure is 100% carbon fibre Prepreg material. The sole in covered with a trimable elastic plastic material. The inside of the spring element is coated in the material “Dyneema” Trimable sole Special designed shape for longer durability WalkOn Reactionplus Global Launch Presentation | NEO

3. General product description Mode of action Mild deviations in the knee joint alignment in the frontal and sagittal plane can be corrected with the help of pronation/ supination or heel/toe wedges. The heel/toe pad 29U22 could be used (as for as 28U24) AB frontal sagittal WalkOn Reactionplus Global Launch Presentation | NEO

3. General product description Mode of action For a perfect fitting with the best as possible foot support we always recommend a custom fabricated insole to place over the WalkOn Reactionplus trimable sole The insole plays an important part in realigning a malpositioned foot, particularly if the medial ankle or arch requires relief from the carbon strut. (as for 28U24) AB WalkOn Reactionplus Global Launch Presentation | NEO

3. General product description Mode of action; Lateral Pronation Traction Kit 28Z10 To prevent or correct a slight supination tendency of the foot during walking, the lateral pronation traction kit (includeded) could help. It can be easily fitted and adapted. (as for 28U24) AB WalkOn Reactionplus Global Launch Presentation | NEO

3. General product description Features and Benefits (as 28U24) Cosmetic appearance Medial view: The medial strut follows the anatomic shape of the medial ankle joint and works like a spring Lateral view: Nothing disturbs the normal shape of the shoe and the ankle AB WalkOn Reactionplus Global Launch Presentation | NEO

3. General product description Features and Benefits (as 28U24) Trimmable sole Easy to fit the patient. Very good connection for glued insoles. No sharp edges inside the shoe. AB WalkOn Reactionplus Global Launch Presentation | NEO

3. General product description Features and Benefits (as 28U24) Asymmetrical design Easy handling for the patient Lateral wings are longer Positioning of the straps is easier Donning and doffing is more comfortable AB WalkOn Reactionplus Global Launch Presentation | NEO

3. General product description Features and Benefits (as 28U24) Unique and exclusive use of Outlast® high-tech textile with adaptive temperature control. Adapts to thermal changes Reduces perspiration Absorb excess heat Reduces overheating Reduces chilling AB http://www.outlast.com/de/technologie/certified-space-technology/ WalkOn Reactionplus Global Launch Presentation | NEO

As for the complete WalkOn Line 4. Sizing As for the complete WalkOn Line WalkOn Reactionplus Global Launch Presentation | NEO

4. Scope of delivery Order numbers and content of 28U25=* The spare parts are complete interchangeable with the parts from the WalkOn Reaction 28U24=* AB WalkOn Reactionplus Global Launch Presentation | NEO

4. Scope of delivery Order numbers and content of 28U25=* Carbon fiber WalkOn Reactionplus 28U25=* Lateral Pronation Traction Kit 28Z10 Instruction of use 646G816 Heel/Toe pad 29U22 User information 646D138 Tibia bone pads 29U23 AB WalkOn Reaction (Cover) liner including straps and y-closure 29U24=*. The same as for the WalkOn Reaction! WalkOn Reactionplus Global Launch Presentation | NEO

5. Spare parts Spare part numbers 28Z10 28U25=* AB Spare parts order numbers with stock availability (SAP) Walk On Reaction (Cover) Liner including straps and y-Closure 29U24=* Y-Closure BIG 29U25=1 Y-Closure SMALL 29U25=2 Tibia bone pads 29U23 Heel/Toe pad 29U22 Lateral Pronation belt (useable for the complete Walk On Range) 28Z10 Promotion and test tool for customers and sales WalkOn Reactionplus Fit Kit 28T4 AB 28U25=* WalkOn Reactionplus Global Launch Presentation | NEO

6. Fit Kit 28T4 is available Fit Kit content: For testing the right size and stiffness of the WalkOn Reactionplus in the Fit Kit all 8 sizes are included. Fit Kit content: 28U25=L36-39 + Cover   28U25=L39-42 28U25=L42-45 +Cover 28U25=L45-48 28U25=R36-39 28U25=R39-42 28U25=R42-45 28U25=R45-48 22U23 Tibia pad x 4pcs. 22U22 Heel/ Toe pad x 2pcs. 28Z10 Lateral Pronation Traktion Kit x 2pcs. AB WalkOn Reactionplus Global Launch Presentation | NEO

7. Product information 646D387=GB WalkOn Reactionplus Global Launch Presentation | NEO

7. Selection Guide Poster 646F447=EN WalkOn Reactionplus Global Launch Presentation | NEO

8.WalkOn Reactionplus Sizing, height and patient weight are influence the functioning of the WalkOn Reaction and Reactionplus Therefore all sizes are included in the Fit Kits for these anterior shell AFOs Size 45-48 400mm Size 42-45 377mm Size 39-42 355mm Size 36-39 333mm AB WalkOn Reactionplus Global Launch Presentation | NEO

8.WalkOn Reactionplus Trimable sole with unique rubber carbon fibre connection 25-30mm 9-11mm 20-23mm AB WalkOn Reactionplus Global Launch Presentation | NEO

Median of Ankle joint stiffness in dorsal and plantarflexion 8.WalkOn Reactionplus vs. Key Competitor Median of Ankle joint stiffness in dorsal and plantarflexion WalkOn Reactionplus Global Launch Presentation | NEO

8.WalkOn Reactionplus vs. Key Competitor WalkOn Reactionplus Global Launch Presentation | NEO

Durability, strenght measures in comparison 9.Durability and Quality testing Comparison to Competition and WalkOn Family Durability, strenght measures in comparison Fore foot / lever arm stiffness test Interaction with the audience: - Self test the stiffness with the aperature WalkOn Reactionplus Global Launch Presentation | NEO

Fatigue strength test under repeated bending stress 9.Durability and Quality testing Comparison to Competition Fatigue strength test under repeated bending stress + 2 Mio. cycles with a loss of 20% strength in the end of 2 Mio cycles Key competitor ~800.000 cycles min. 50% loss of strength WalkOn Reactionplus Global Launch Presentation | NEO