We can…. 2 GLOBAL REFERENCES 01.09.2014 Rev: 00 References :

Slides:



Advertisements
Similar presentations
Using Ground Source Heat Pump The Avenue Centre.
Advertisements

eQuest Quick Energy Simulation Tool
1 Optimizing the Efficiency of the NCAR-Wyoming Supercomputing Center Ademola Olarinde Team Member: Theophile Nsengimana Mentor: Aaron Andersen August.
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
Basic Refrigeration Cycle
Using Copper Water Loop Heat Pipes to Efficiently Cool CPUs and GPUs Stephen Fried President Passive Thermal Technology, Inc.
HVAC System Design PES Institute of Technology. Objective Goal: To develop an automotive air-conditioning system that is smaller and lighter than with.
Components of HVAC System
DATA ONE, EUROPEAN OPERATIONS CENTRE, ST. PETERSBURG, RUSSIA Presentation of Design Proposal.
Advanced Direct Evaporative Pre-Cooling for Air Cooled Condensers (DEPACC) Program Overview Technology Overview Energy Savings Customer Benefits 1.
Heat pumps and their economics. There has been fluctuations before Johnson Controls2.
WELCOME FROM Ireland. The History of Evaporative Cooling Evaporative cooling is the oldest form of air conditioning ever used The ancient Greeks used.
PG&E and Altera Data Center Energy Efficiency Project.
Bereichskennung oder Produktname Process Instrumentation and Analytics Januar, 2003 Folie 1 A&D PI2 SE1 Siemens Process Analytics in the Cement Industry.
Engineer Presentation
Air Conditioning. Definition: Any treatment of the environment air within a building is air conditioning. Air cooling is any process that reduces air.
UTSW Thermal Energy Plants, Power Generation and Electrical System What do we do to meet the Emission Reduction, Energy usage Reduction and Electrical.
ISAT Module III: Building Energy Efficiency
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
Objective Learn about Cooling and Cooling systems Define heat pump Learn about energy storage systems.
Thermodynamics of Industrial Cooling Towers
Natural Draft Cooling Towers
High Density Cooling Air conditioning for high density applications
Overview of Liquid Cooling Systems Peter Rumsey, Rumsey Engineers.
Perfect solution for large building
Important variables Water: Air: Conversion:
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Mission Energy: Energy Efficient Cooling How Data Centre energy consumption and operating costs can be significantly reduced through readily available.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
DESIGN AND PERFORMANCE EVALUATION OF AN EVAPORATIVE HEAT EXCHANGER A.O. MURITALA, S.O. OBAYOPO, S.K. FASHOGBON, O.T. POPOOLA*, S.A ADIO Department of Mechanical.
Lecture Objectives: Finish with software intro HVAC Systems
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
BCWC Water-cooled water chillers with centrifugal compressor/s
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
ELECTRICITY COST OF CHILLER AND COOLING TOWER PUMPS KILLING YOU? We Have The RIGHT Solution just for YOU! + =
IMPROVING THE EFFICIENCY GEOTHERMAL or GROUND SOURCE HEAT PUMPS.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Lecture Objectives: Discuss the exam problems Answer question about HW 3 and Final Project Assignments Building-System-Plant connection –HVAC Systems.
1 PCE 2.1: The Co-Relationship of Containment and CFDs Gordon Johnson Senior CFD Manager at Subzero Engineering CDCDP (Certified Data Center Design Professional)
A New (Rational) Way To Condition Air (and Save Energy) AEE, Philadelphia February 18 th 2016 Andrew Mongar, President, AirGreen LLC.
Bernard Boutherin 1 Feedback after four years of operation.
Lecture Objectives: Review Psychrometrics Introduce Air Handling Unit
Free Air Cooling for Data Centres
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Combined Hot-Smoking & Cooking Installation
Unit 2: Chapter 2 Cooling.
The Data Center Challenge
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
5.2.7 Evaporative Coolant System
Using Heat to Increase Cooling George Hannah BEng (Hons) CEng MIMechE
WELCOME Indoor Chillers.
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
High Quality ECONET Manufactured by Manor
Thermal Energy Storage
Top Quality & Cost Effective ECONET Manufactured by Maniks
Maniks High Quality ECONET for Better Performance
Chilled Beam Performance:
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Lecture Objectives: Review Psychrometrics Introduce Air Handling Unit
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRK Sales Training Program
What is Ecomesh and What are the applications of Ecomesh?
Liebert DSE High efficiency thermal management
NRL NRL - Welcome to the NRL Sales Training Program
Presentation transcript:

We can…

2 GLOBAL REFERENCES Rev: 00

References :

Rev: 00 The History of Evaporative Cooling Evaporative cooling is the oldest form of air conditioning ever used The ancient Greeks used to fill terracotta pots full of water and leave them by doors and windows to benefit from evaporative cooling The Arabs hung wet blankets over doors and windows to achieve the same effect But this is direct evaporative cooling. The absolute humidity will increase. Canovate is introducing the Next Generation Evaporative Cooling for Datacenters

Two 100% separated air streams. Outside air and datacenter air. Only max.50 % of outside air to cool 100 % datacenter air. Forced evaporation of the water on the surface of the plates 1.Hot air from data center 2.Hygroscopic layer 3.Ambient air intake 4.Water supply 5.Scavenger air 6.Cool supply air. Plates Hygroscopic Layer INDIRECT ADIABATIC COOLING How does Indirect Adiabatic Cooling technology works? Secondary fan Primary fan Next Generation Evaporative Cooling Adiabatic cooling İnside

The power of evaporating water: Polypropyleen plates

The power of evaporating water: Primary airflow

The power of evaporating water: Hygroscopic Layer

The power of evaporating water: Secondary airflow

The power of evaporating water: Adiabatic Cooling

The power of evaporating water: High Efficient Adiabatic Cooling

*Source: internal analysis of various competitors data ASHRAE TC Recommended Allowable A1 Accoording the temperature guidline of ASHRAE

Nominal load Partial load 75 % Energy saving 50 % 75 % partial load means up to 50 % energy saving

The electrical cost of different cooling systems SystemEER ( Energy Efficiency Ratio) Needed Electrical power for cooling 1 MW [kW] Typical Energy cost (Year) [€] DX (CRAC)3333€ CW (CHILLER + CRAC) 5200€ CW + FREE COOLING10100€ INDIRECT ADIABATIC3033€

The heat exchanger forms the basis with simple easy to understand design and use heat exchanger Two fans

Easy controls are designed well, easy to use and able to communicate with all building management systems

Rev: 00 At low ambient temperatures the Canovate CACxxx Series can achieve 100% free cooling. THREE OPERATING MODES Free Cooling 0˚C to 15˚C Dry bulb temperature

Rev: 00 Indirect Adiabatic Cooling 15˚C to 35˚C As the ambient temperature begins to increase, the heat exchanger requires more airflow to deliver the required cooling, the ambient fans ramp up accordingly. The system will start with wetting the heat exchanger and run as a indirect adiabatic cooler.

Rev: 00 Top up Operation above 35 ˚C (Indirect adiabatic & mechanical cooling) If the supply temperature cannot be met by indirect adiabatic cooling alone (i.e. where lower supply temperatures or higher more humid ambient conditions are present), the DX system will be activated. 35 ˚C

Rev: 00 Canovate CACxxx Series Benefits 1. Highest water efficiency 2. Ultra-energy efficient unit with typical pPUE below Maximum economizer utilization 4. Compact size 5. Flexible configuration

Rev: 00 Flexible configuration Flexible configuration (50,100, 200,300 and 400 kW standard unit sizes)

Rev: 00 Canovate Air Handling Solutions Canovate CACxxx Series save money,reduced energy consumption,eliminates high ambient problems and serve as an energy efficient cooling solution for datacenters. Reduced Running Cost Reduced Maintenance Improved Reliability Increased Capacity Self Cleaning Filter Longer Compressor Life Controls BMS compatibility Supply air temperature control Air flow and pressure monitoring Dual power supply (ATS)

Rev: 00 Canovate Air Handling Solutions Wall or roof optimised connections Highest water efficiency Ultra-energy efficient unit pPUE below 1.2 Adiabatic system with full UV sterilisation N+1 fan configuration for increased efficiency Flexible configuration (50,100, 200, 300 and 400 kW standard unit sizes) High mechanical cooling energy efficiency ratio (EER)

COST EFFECTIVEminimal maintenance requirements, minimal power infrastructure RELIABLE by a minimum of moving parts, high quality components and high quality finish ENERGY-EFFICIENT due to EC fans, dynamic control and elimination of a water pump ENVIRONMENTALLY FRIENDLY only water and air as cooling agent and low energy consumption, low CO2 emission HYGIENICno still standing water, no algea, no legionella risk SAVINGSup to 90% energy saving on conventional cooling system EXPERIENCEmore than 10 years of experience in cooling systems. Using Adiabatic Cooling technology means......

A Case Sample Study for Riyadh / Saudi Arabia

Thank you for listening!