Investigating Out of Specification Results

Slides:



Advertisements
Similar presentations
Bioavailability Bioavailability means the rate and extent to which the active substance is adsorbed from a pharmaceutical product and become available.
Advertisements

Quality is a Lousy Idea-
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
Out of Specification and Atypical Test Results
Mentoring Session Technical Assistance Committee Method Modifications.
Good Manufacturing Practices Guilin, PRC Dr AJ van Zyl for Quality Assurance and Safety: Medicines Medicines Policy and Standards Health Technology and.
ISO Culture SHOQ Quiz 1. This program must be run in MS PowerPoint and requires sound. 2. Click “View” and then “Slide Show”. 3. Click “Continue”
Result validation. Exercise 1 You’ve done an analysis to the best of your ability using the correct procedure. Is your answer correct? possibly, hopefully.
Conducting systematic reviews for development of clinical guidelines 8 August 2013 Professor Mike Clarke
World Health Organization
Corrective & Preventive Action Programme l Corrective and preventive action managed by one programme l Closely linked to the internal audit programme l.
Dr Samah Kotb Lecturer of Biochemistry 1 CLS 432 Dr. Samah Kotb Nasr El-deen Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Nasr.
Lecture 8. Quality Assurance/Quality Control The Islamic University of Gaza- Environmental Engineering Department Environmental Measurements (EENV 4244)
Importance of Quality Assurance Documentation and Coordination with Your Certified Laboratory Amy Yersavich and Susan Netzly-Watkins.
Calibration (Qualification) of Centrifuge
Handling of out of specification results Michael Koupparis University of Athens.
Quality Assurance/Quality Control Policy
Detect Limits as Representation for a Standard VAP Rule Discussion Dawn Busalacchi Risk Assessor, DERR, Central Office VAP Rule Discussion Dawn Busalacchi.
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
Chemometrics Method comparison
Unit #7 - Basic Quality Control for the Clinical Laboratory
Effectively applying ISO9001:2000 clauses 5 and 8
Quality Assessment 2 Quality Control.
World Health Organization
Validation of Analytical Method
IB Internal Assessment Design. Designing an Experiment Formulate a research question. Read the background theory. Decide on the equipment you will need.
Inspection Issues in the Analytical Laboratory: An FDA Perspective Yvonne McKnight Chemist US Food and Drug AdministrationPhone: x
Author: J R Reid Extended Investigation Introduction Planning an Investigation Writing a Report Data Collection Data Processing Conclusions and Discussions.
Analytical considerations
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
HD 2007 Rule Diesel Fuel Sulfur Testing and Sampling Methods and Requirements US EPA Office of Transportation and Air Quality November 20, 2002.
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
Important informations
Quality Assurance How do you know your results are correct? How confident are you?
Data Analysis: Quantitative Statements about Instrument and Method Performance.
Why do we need to do it? What are the basic tools?
QC THE MULTIRULE INTERPRETATION
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
Rachel Martin Displacement and Density. Introduction Animals are dosed by being given a specific volume of a test item (or control) formulation.
QC/QA.
Trials and Tribulations of Developing a Method for Quantification of Aerosol Chamber Concentration Richard Snell, Dose Concentration Analysis GSK.
Dean R Hatt. Opening Thought  In a regulated GLP environment, we are sometimes reluctant to change, believing what we have always done, and what we have.
Inhalation Toxicology Support Optimisation David Howie April 2014.
Data Quality Assurance/ Quality Control. QA/QC Requirements for RECAP Submittals Data generated using rigorous analytical methods Data must be analyte.
Fiona McGuinness 29 April 2015 Harmonising Formulation Analysis Procedures.
Testing.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
Control Charting: Lessons Learned Along the Way Why, What, and How Stacie Hammack Florida Department of Agriculture and Consumer Services Food Laboratories.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
 Remember Chemistry panel Quality Control:-  In a medical laboratory, it is a statistical process used to monitor and evaluate the analytical process.
 Routine viral diagnostics: indirect and direct detection of viruses. ◦ Indirect detection: serological tests; ◦ Direct detection:  Viral antigens;
TTB M (04/2010) Methods Criteria and Performance Patricia Nedialkova, Ph.D., TTB International Wine Technical Forum May 7, 2015 Prepared for the.
EQUIPMENT and METHOD VALIDATION
1. Our Presentation Topic: Importance Of Validation & Qualification In Pharmaceutical Industries Presented By: Md. Tanjir Islam (Group C) 2.
Diagnostic clinical chemistry
Veterinary Practice Laboratory Unit 1 Chapter 5 Quality Control and Record Keeping Copyright © 2015 by Mosby, an imprint of Elsevier Inc. All rights reserved.
A LOOK AT AMENDMENTS TO ISO/IEC (1999) Presented at NCSLI Conference Washington DC August 11, 2005 by Roxanne Robinson.
Quality is a Lousy Idea-
Unit #6 - Basic Quality Control for the Clinical Laboratory
World Health Organization
Janice L. Willey Senior Chemist
Quality is a Lousy Idea-
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
به نام خدا تضمين کيفيت در آزمايشگاه
Chapter 5 Quality Assurance and Calibration Methods
Why Use Them? By: Marcy Bolek – Alloway
World Health Organization
Quality Control Lecture 3
Presentation transcript:

Investigating Out of Specification Results Fiona McGuinness If you want to remove slide numbering follow these steps: View Master view - Slide master Master layout - Remove tick on Footer

Introduction What do we mean by OOS, OOT, atypical or unexpected results? Documented procedure Investigation What happens when you can’t find the cause? Examples Questions

What do we mean…? Out of Specification (OOS) Out of trend (OOT) Result that does not comply with stated accepted criteria Out of trend (OOT) A stability result that does not follow the trend of other stability results during a stability study A result that does not follow the trend based on data already collected with the same compound Atypical May be within specification but unexpected or questionable All unexpected results!

Documented Procedure Important that all laboratories have a fully documented OOS investigation procedure Clearly state what the investigation will be based on, what you will do in each case, actions and outcomes from the investigation Clients and regulatory agencies like to see a procedure and that it is being followed!

Initial Investigation First step is to QC Check the data generated to ensure that no identifiable calculation or preparation errors have been made Investigate the analysis…. Calibration standards, extraction volumes, dilution steps etc Instrument set-up, injection volumes, mobile phases, diluents, instrument working…

Re-dilution An investigative run Has a dilution error been made? What if dilution results are different? Don’t cherry pick results! Confirm results by a 3rd dilution!

Preparation of the Formulation Check the request, method, weights of test substance and vehicle as appropriate. Check calculations

Contingency Analysis No obvious analytical error (including dilutions), no obvious preparation error… Perform analysis of contingency samples

What happens when we can’t find the cause of an unexpected result? Meeting Root Cause Analysis investigation Corrective and Preventative Actions Analysis of next formulated occasion Discussion and agreement with senior members of department and SD

Fishbone

5 Whys

Analysed concentration (mg/ml) Example 1 Week of Formulation Group Nominal Analysed concentration (mg/ml)   RME % Difference from Mean inclusion Analysis 1 Analysis 2 Mean (%) (mg/ml) 13 1 ND - 2 0.75 2.6904 2.734 2.71 261.3 -0.80 0.80 3 1.5 1.4978 1.5041 1.50 0.0 -0.21 0.21 4 2.75 0.61669 0.60652 0.61 -77.7 0.83 -0.83 Group 2 samples are above the quantification range Group 4 samples are below the quantification range Obvious error?

Investigation Samples had been booked into the department in the wrong order Analyst followed the booking in rather than looking at the labels of the samples New samples were taken from the bulk sample provided by Pharmacy

Analysed concentration (mg/ml) Re-sampled Analysis Week of Formulation Group Nominal Analysed concentration (mg/ml)   RME % Difference from Mean inclusion Analysis 1 Analysis 2 Mean (%) (mg/ml) 13 1 ND - 2 0.75 0.72346 0.71577 0.720 -4.0 0.53 -0.53 3 1.5 1.4978 1.5041 1.50 0.0 -0.21 0.21 4 2.75 2.7186 2.5703 2.64 2.80 -2.80 All samples now within specification Original results for Groups 2 and 4 not reported due to an identified analyst error

Analysed concentration (mg/ml) Example 2 Week of Formulation Group Nominal Analysed concentration (mg/ml)   RME % Difference from Mean inclusion Analysis 1 Analysis 2 Mean (%) (mg/ml) 1 ND - 2 10 9.6428 8.1326 8.89 -11.1 8.50 -8.50 3 30 27.686 26.675 27.2 -9.3 1.86 -1.86 4 60 58.827 57.72 58.3 -2.8 0.95 -0.95 Investigation shows no calculation errors Re-dilution confirms the results No preparation errors found with formulation preparation

Analysed concentration (mg/ml) Contingency Analysis Week of Formulation Group Nominal Analysed concentration (mg/ml)   RME Precision % Difference from Mean inclusion Analysis 1 Analysis 2 Mean (%) from mean (mg/ml) 1 2 cont 10 9.9601 10.022 9.99 -0.1 0.44 -0.31 0.31 Contingency analysis showed that results were acceptable What should we do about the original analysis? Outlier test?

Outlier Test – Dixon’s Q Test   n 3 4 5 6 7 8 9 10 Q90% 0.941 0.765 0.642 0.560 0.507 0.468 0.437 0.412 Q95% 0.970 0.829 0.710 0.625 0.568 0.526 0.493 0.466 Q99% 0.994 0.926 0.821 0.740 0.680 0.634 0.598

Analysed concentration (mg/ml) Reportable Results 8.1326 mg/mL was rejected from the mean as an outlier with 90% confidence. Group Nominal Analysed concentration (mg/ml)   RME Precision % Difference from Mean inclusion 1 2 3 4 Mean (%) from mean (mg/ml) 10 9.6428 [8.1326] 9.9601 10.022 9.87 -1.3 2.06 -2.35 - 0.86 1.49

Example 3 UV Method – controls usually reportable as <LOQ One sample (from 3) showed a response >LOQ Full spectrum scan did not show a test item response No dilutions available to re-read Time sensitive as pre-dose analysis!

Contingency analysis The next 3 samples were read <LOQ Full scans were done of all controls = clear of test item response Rejected the initial sample result as anomalous as 5/6 controls were <LOQ Full investigation was not required as able to demonstrate the control group was clear by full spectrum scans (of all controls) and results of 5/6 controls

Any Questions?