Www.hvac.vn Gas Mass Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.

Slides:



Advertisements
Similar presentations
MAO Flow Meters Sales Deck | Presentation Title What is the MAO Flow Meter? The MAO flow meter is an instrument used for monitoring or measuring.
Advertisements

Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
SOLARIS 3-GAS METER Complete operation of Solaris multi-gas meter can be found on the LAFD Ethernet.
RJ Mann Catalytic Monitoring Systems. RJMCMS 100 Low Cost Single Engine Monitoring System Monitors Pre and Post Catalyst Temperatures, Differential Pressure.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Thermostats The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Dr C Narain Spantech Products, South Godstone, Surrey, UK The exclusive representative for ACD in Europe, Middle East and India.
HVAC Air Flow Measurement The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Open Channel Flow Panel Meters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Paddlewheel Flow Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Calibration Procedure.  A winch calibration is completed via a linear interpolation between 2 points.  Requires 2 references  Known lower weight 
Copyright Albion Devices, Inc., Demonstration of MicroComp micro-computer gaging system from Albion Devices, Inc.
Remote Monitoring and Management Solutions ®
Selection of measuring instruments
9/23/02 Program Flow Chart User Hits Key Setup Key Product Key Product Program Direct Robot Programming Area Perimeters Hopper Position Assembly Area Position.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
AccuMax Multi-Point Injection Mechanics
1 Training Manual: KI7400 & 7800 Series Sources Level 1, V2.0 August 2008.
PAJ GROUP WE BELIEVE IN QUALITY Development & production of advanced mechatronics.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
1 Starting & Stopping Motors Pico Pico LAB#4. 2 Program a series of three basic ladder logic rungs. These basic rungs are the most common rungs found.
Antek 6200 ® Meet Sulfur Regulations and Control Your Process with Continuous Measurements Product Presentation.
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
Submersible Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Electromagnetic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
High Sensitivity Smoke Detection
Calibration Savvy. Calibration and Conformance  Calibration: Check a measurement against a known universally recognized standard to determine any deviation.
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
1 April 29, 1999 ZENO DATALOGGER Texas Natural Resource Conservation Commission.
Overview of MSWS Control of 212-LC July 15, 2006.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Ultrasonic Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Industrial Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Gas Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Handheld Digital Manometers The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Differential Pressure ATEX Enclosures The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
Miscellaneous Test Equipment Combustion, Tachometers, Hygrometers The materials included in this compilation are for the use of Dwyer Instruments,
Ultrasonic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Powder & Bulk Level Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Temperature Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Water Detectors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Vibration Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Pressure Transmitters and Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Photovoltaic Power System Monitor Josh Stone Ryan Mann Art Barnes Austin Fisher.
Series RHP Temperature and Humidity Transmitter The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Air Handler Demonstration The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Water Horner APG, LLC June 4, What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured.
Flow Technology Overview The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
LDA Large Display for Analog Inputs
FEEDER PROTECTION UNIT
NSA-7000 Stylish flush mount Network Sensors
Product Training Module
August 23, 2000 R.N. Dubois Dow Chemical
SKC CHEK-MATE CALIBRATOR
Gas chromatography Software
Presentation transcript:

Gas Mass Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2014 Dwyer Instruments, Inc.

Overview GFM2 – Gas Mass Flowmeter GFM3 – Gas Mass Flowmeter Push Button Configuration GFM4 – Gas Mass Flowmeter Temperature and Pressure Monitoring

GFM2 - Specifications Service: Clean dry gases Accuracy: ±1% FS Temperature Limits: 0 to 50 °C Power Supply: 11 to 26 VDC Leak Integrity: 1 x ml/sec of He Flow Ranges: From 10 ml/min to 100 l/min Calibration: NIST certificate standard

GFM2 - Features Programmable totalizer Two user-programmable electromechanical SPDT relays with latching option

GFM2 - Features User-selectable analog 0 to 5 VDC or 4 to 20 mA outputs Internal conversion factors for up to 32 gases Digital interface option RS-232, RS-485, or Profibus

GFM3 - Specifications Service: Clean dry gases Accuracy: ±1% FS Process Temperature Limits: -10 to 50 °C Power Supply: 12 VDC; 15 VDC, or ±24 VDC Leak Integrity: 1 x ml/sec of He Flow Ranges: From 10 ml/min to 100 l/min Calibration: NIST certificate standard

GFM3 - Features Four button keypad and large LCD with backlight Programmable 12 digit totalizer Two SPDT relays with latching option for high or low alarm outputs

GFM3 - Features Internal conversion factors for up to 32 gases Digital interface option RS-232, RS-485, or Profibus

GFM4 - Specifications Service: Clean dry gases Accuracy: ±1% FS Process Temperature Limits: -10 to 50 °C Power Supply: 12 VDC; 15 VDC, or ±24 VDC Leak Integrity: 1 x ml/sec of He Flow Ranges: From 10 ml/min to 100 l/min Calibration: NIST certificate standard

GFM4 - Features Flow, Pressure, and Temperature measurement and output Four button keypad and large LCD with backlight and programmable 12 digit totalizer

GFM4 - Features Two SPDT relays with latching option for high or low flow or pressure alarm outputs Internal conversion factors for up to 32 gases Digital interface option RS-232, RS-485, or Profibus

Flow Scale Options FLOW RATE BODY SIZE REQUIRED FOR THE GIVEN GAS AIRARC2H2C3H8C4H10CH4COCO2HEHFH2N2NH3O2SO2 10ml/min ml/min ml/min ml/min ml/min ml/min ml/min 010 2l/min 010 5l/min l/min l/min l/min l/min l/min l/min l/min 100 l/min 100

Applications Critical flow testing environments such as analytical laboratories Used to measure and control gas flow rate into environmental chambers to provide accurate gas concentrations

Applications Gas burner metering Used to measure gas flow rate to burner, and totalize gas consumption

Applications Widely used in equipment for the semiconductor industry Chemical Vapor Deposition Etching Backside Wafer Cooling

Applications Semiconductor Industry: Chemical Vapor Deposition Precise amounts of precursor gases are flowed into a reaction chamber to create thin film coatings

Applications Semiconductor Industry: Wafer Etching Inert gas flow is used in a high flow purge step between the wafer etching process and the cleaning process to limit wafer exposure to moisture or oxygen

Applications Semiconductor Industry: Backside wafer cooling Gases, such as helium, flow across the wafer to reduce the temperature during processing

Applications Pharmaceutical Industry Mass flowmeters are used to monitor precise air flow rates in tablet coating machinery

Applications Pharmaceutical Industry Mass flowmeters are used to measure the amount of inert and reactant gases into bioreactors

GFM3 – Demonstration GFM3 with Power and communication connection cable

GFM3 – Demonstration 25 pin connection for power, outputs, and communication Process inlet connection Process outlet connection Product label showing model, calibrated flow rate and gas, and serial number User Interface Buttons Backlit LCD Display

GFM3 – Demonstration Process value Calibrated gas Full scale range Totalizer value Flow rate units

GFM3 – Demonstration Display will show some amount of flow while warming up

GFM3 – Demonstration Within a few minutes the flowmeter will settle at zero

GFM3 – Demonstration Changing Units of Measure Press to enter the Main Menu Use the and keys to cycle through the menu and highlight sub-menu “Units of Measure” Press to enter into the sub menu

GFM3 – Demonstration Changing Units of Measure - Continued Use the and keys to cycle through the menu options Highlight “mL/min” and press to select this option Display will return to the Main Menu and “Current Units: mL/min” will be displayed at the bottom Press to exit the main menu

GFM3 – Demonstration Units changes from % to mL/min

GFM3 – Demonstration Configuring the Totalizer Press to enter the Main Menu Use the and keys to cycle through the menu and highlight sub-menu “Totalizer” Press to enter into the sub menu

GFM3 – Demonstration Configuring the Totalizer Use the and keys to cycle through the menu options Highlight “Mode Run/Stop” and press to select this option Press once to highlight “Run” and then press to activate the totalizer TOT: S at the bottom of the display will change to TOT:R to indicate the totalizer is in run mode

GFM3 – Demonstration Configuring the Totalizer The “Start at Flow” option is used to set a minimum flow rate before the totalizer will start accumulating the total flow The “Stop at Total” option is used to set a maximum limit for the total flow accumulation These values are shown at the bottom of Totalizer menu display for reference

GFM3 – Demonstration Configuring the Totalizer The totalizer value can be reset with the “Reset to Zero” option

GFM3 – Demonstration Totalizer