Collimator BPM electronics – Results from the lab, SPS and LHC

Slides:



Advertisements
Similar presentations
Analog-to-Digital Converter (ADC) And
Advertisements

M.Gasior, CERN-AB-BIBase-Band Tune (BBQ) Measurement System 1 Base-Band Tune (BBQ) Measurement System Marek Gasior Beam Instrumentation Group, CERN.
INSTITUT MAX VON LAUE - PAUL LANGEVIN Fast Real-time SANS Detectors Charge Division in Individual, 1-D Position- sensitive Gas Detectors Patrick Van Esch.
Chapter 2 Data and Signals
Announcements Assignment 8 posted –Due Friday Dec 2 nd. A bit longer than others. Project progress? Dates –Thursday 12/1 review lecture –Tuesday 12/6 project.
Analog to Digital Conversion. Introduction  An analog-to-digital converter (ADC, A/D, or A to D) is a device that converts continuous signals to discrete.
Update of EXT Stripline BPM Electronics with LCLS-style Digital BPM Processors Glen White, with slides by Steve Smith 15 December 2009 ATF2.
Lecture 9: D/A and A/D Converters
Testing and Development of Feed-Forward System for ATF2 A. Kalinin Accelerator Science and Technology Centre, Daresbury Laboratory, UK Fifth ATF2 Project.
The EMMA Turn-by-Turn BPM System A. Kalinin ASTeC Daresbury Laboratory STFC EMMA Commissioning Workshop Daresbury Laboratory, 21 May 2009.
Data Acquisition Systems ACES Presentation Brad Ellison March 11, 2003.
Introduction to Data Conversion
Test of LLRF at SPARC Marco Bellaveglia INFN – LNF Reporting for:
PH4705/ET4305: A/D: Analogue to Digital Conversion
 Distortion – the alteration of the original shape of a waveform.  Function of distortion analyzer: measuring the extent of distortion (the o/p differs.
Chapter 4 Digital Transmission
Frequency to Voltage Converter and Voltage to Frequency Converter Where an instrumentation system is based mainly on capturing voltage signals (analogue.
Feed forward orbit corrections for the CLIC RTML R. Apsimon, A. Latina.
Oscilloscope Tutorial
Electronic Devices Ninth Edition Floyd Chapter 13.
Octiv RF Power monitoring technology “. Talk Outline Impedans VI technology Introduction to power monitoring Need for VI Probes Why IV sensors are needed.
Key Specifications for Tevatron BPM Hardware Architecture Choices Jim Steimel.
Chapter 19 Electronics Fundamentals Circuits, Devices and Applications - Floyd © Copyright 2007 Prentice-Hall Chapter 19.
Understanding ADC Specifications September Definition of Terms 000 Analogue Input Voltage Digital Output Code FS1/2.
Electronics for PS and LHC transformers Grzegorz Kasprowicz Supervisor: David Belohrad AB-BDI-PI Technical student report.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
By Grégory Brillant Background calibration techniques for multistage pipelined ADCs with digital redundancy.
BPMs and HOM-BPMs for the XFEL Linac N. Baboi for the BPM and the HOM teams (DESY, CEA-Saclay, SLAC, FNAL, Cockroft/Daresbury) XFEL Linac Review Meeting,
SIGMA-DELTA ADC SD16_A Sigma-Delta ADC Shruthi Sujendra.
M.Gasior, CERN-BE-BIBE-KT Innovation Day, 3 June Base Band Tune (BBQ) measurement systems - observing beam oscillations with sub-micrometre amplitudes.
Introduction to collimators Integration of BPM Mechanical design Electrical design Processing Simulations Results Conclusions & Outlook.
Beam phase and intensity measurement Grzegorz Kasprowicz Richard Jacobsson.
Feed forward orbit corrections for the CLIC RTML R. Apsimon, A. Latina.
1 FermiLab Recycler Ring BPM Upgrade Based on Digital Receiver Technology R. Webber, J. Crisp, P. Prieto, D. Voy, C. Breigel, C. McClure, M. Mengel, S.
Basic BPM Hardware Theory Jim Steimel. Wall Current Charge in a cylindrical perfectly conducting pipe produces an equal and opposite image charge at the.
BI day 2011 T Bogey CERN BE/BI. Overview to the TTpos system Proposed technical solution Performance of the system Lab test Beam test Planning for 2012.
The Physical Layer Lowest layer in Network Hierarchy. Physical transmission of data. –Various flavors Copper wire, fiber optic, etc... –Physical limits.
1 C. Simon CLIC Instrumentation workshop BPM C. Simon on behalf of the Saclay’s group CLIC Instrumentation workshop 2 nd - 3 rd June.
I could be brief… LHC BPM Status. I could be brief… BPM – Water cooled racks Thermalized Racks (BPM & BLM) consist of: o A temperature controller module.
Marc Ross Saturday, June 5, 2004 nanometer BPM status and plans.
M.Gasior, CERN-BE-BI8th DITANET Topical Workshop on Beam Position Monitors, January 2012, CERN 1 BPM Signal Processing with Diode Detectors Marek.
FONT Hardware Processing electronics and current beam tests Stephen Molloy Queen Mary, University of London.
BI day /12/00 1 PIPOS Project (TT2 & TT10) (Beam performances) G. Vismara  Present situation  Proposals  Beam parameters  Technical solution.
Philip Burrows ATF2 project meeting 14/1/111 Plans for ATF2 IP Feedback Philip Burrows, Colin Perry John Adams Institute Oxford University.
CLIC09 Workshop October 2009Drive beam BPM’sLars Søby 1 Drive Beam BPM’s CLIC 09 work shop, CERN, of October 2009, Lars Søby.
Intensity measurements using TRIC Juan Carlos Allica On behalf of: M. Andersen, D. Belohrad, L. Jensen, F. Lenardon, A. Monera, L. Søby 1.
Digital to Analog Converter (DAC)
Very Forward Detectors Workshop on beam position monitoring and detector alignment.
Specifications of Tevatron BPM Upgrade Jim Steimel.
S. Bota – Calorimeter Electronics overview - July 2002 Status of SPD electronics Very Front End Review of ASIC runs What’s new: RUN 4 and 5 Next Actions.
BASIC INSTRUMENTS - oscilloscopes
M.Gasior, CERN-BE-BILHC Optics Measurement and Corrections Review, June Diode ORbit and OScillation (DOROS) System Marek GASIOR Beam Instrumentation.
Development of a High Resolution Cavity BPM for the CLIC Main Beam
The LHC Beam Position System Ad-hoc Working Group on LHC Experiment-Machine Parameter and Signal Exchange 26 th March 2002 Rhodri Jones (SL/BI)
S. Smith LCLS Facility Advisory October 12, Beam Position Monitors Facility Advisory Committee October 12, 2006.
Accuracy of the orbit measurement by KEKB BPM system for the study of ILC damping ring H. Fukuma (KEK) Requirement for the accuracy of BPM data.
A function generator is usually a piece of electronic test equipment or software used to generate different types of electrical waveforms over a wide.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
CLIC Workshop 18 th -22 nd January 2016, CERN 1 Alfonso Benot Morell Manfred Wendt.
Comparison of simulated collimator BPM data to measured data, obtained during SPS collimator MD (8 June, 2011) A. Nosych Fellow, BE-BI-QP Collimator prototype.
FUNCTION GENERATOR.
EUROTeV Diagnostics WP5
for the BI DOROS team (G. Baud, M. Gasior, M. Lasch, J. Olexa)
BCTW calibration status and future
> 50 dB ≤ 500 MHz Non-intercepting beam position measurement
Limits on damping times
Status of muon monitor R&D and construction
Beam Current Monitoring with ICT and BPM Electronics
Feed forward orbit corrections for the CLIC RTML
Breakout Session SC3 – Undulator
Presentation transcript:

Collimator BPM electronics – Results from the lab, SPS and LHC Marek Gasior BE-BI-QP Outline: The principle of the novel Diode ORbit (DOR) measurement system Lab measurements SPS measurements LHC measurements

Collimator BPM electronics: Diode Orbit System WHY diode detectors ? Diode detectors can be used to convert fast beam pulses (LHC bunch length is in the order of 1 ns) from a BPM into slowly varying signals, possible to digitise with high resolution. As the diode forward voltage Vd depends on the diode current and temperature, the output voltage of a simple diode detector also depends on these factors. Simple diode detectors are no good for precise amplitude measurement. Input (Vi) and output (Vo) voltages of a peak detector with an ideal diode Input (Vi) and output (Vo) voltages of a peak detector with a real diode Input (Vi) and output (Vo) voltages of an average-value detector Collimator BPM electronics: Diode Orbit System

Compensated diode detector Compensated diode detector consists of two diode peak detectors, one with single, second – with two diodes. All three diodes are in one package, for good thermal coupling and symmetry of the forward voltages Vd. Two operational amplifiers are used to derive 2 Vd voltage and to add it to the output of the two-diode detector. This way the resulting output voltage is equal to the input peak voltage. To get an “ultimate peak mode operation”, the discharge resistors can be omitted. In this case the discharge is done by the reverse leakage current of the diodes. The asymmetry in the charging conditions becomes less important for larger input voltages. Collimator BPM electronics: Diode Orbit System

Collimator BPM electronics: Diode Orbit System Diode ORbit Front-End Signal of each pick-up electrode is processed separately. The multiplexer is foreseen for calibration with beam signals. The low pass filters decrease the signal amplitude and make the beam pulses longer. The conversion of the fast beam pulses into slowly varying signals is done by compensated diode detectors. These slow signals can be digitised with high resolution, averaged and transmitted at slow rates. All further processing and calculations are done in the digital domain. ADC data sent as UDP packets. Sample averaging is the only data processing done by the microcontroller. Sampling is at 11.7 kHz. Typical averaging is down to 1 Hz. UDP data is received by the host computer, calculating the position, making logging, etc. Simple and robust hardware, high resolution, no beam synchronous timing required. Collimator BPM electronics: Diode Orbit System

DOR FE is still a prototype Collimator BPM electronics: Diode Orbit System

DOR FE connected to two LHC BPMs Collimator BPM electronics: Diode Orbit System

DOR prototype: lab measurements Inputs of all 4 FE channels parallel, simulating beam in the PU centre. Input signal: 10 MHz sine wave, FE gain 25 dB (max). Raw results, without any offset and gain calibration. 24-bit 8-channel ADC sampling at 11.7 kHz, samples averaged in the microcontroller to 50 Hz equivalent sampling, then to 1 Hz for the plots. Front-end channels have 10 Hz LP filters before the ADCs. Amplitude changes due to temperature sensitivity of the signal generator. The amplitude faster jumps may be due to some internal calibration of the generator or somebody (i.e. me) touching the input cables, as during the night signals were much smother. Collimator BPM electronics: Diode Orbit System

DOR prototype: lab measurements The plot repeated from the previous slide Beam position calculated as for an LHC arc pick-up with 49 mm electrode distance. 49 mm of a regular BPM is equivalent to the collimator BPM gap of about 29 mm (as each BPM button is 10 mm below the jaw surface). ”Natural” long term stability shown, no calibration. Collimator BPM electronics: Diode Orbit System

DOR prototype: lab measurements All 4 inputs in parallel, simulating beam in the PU centre and changing beam intensity. Input: 10 MHZ sine wave with slow triangular modulation to simulate intensity changes, FE gain 25 dB (max). Raw results, without any offset and gain calibration. Beam position calculated as for an LHC arc pick-up with 49 mm electrode distance (coll. BPM gap of 29 mm). ADC sampling at 11.7 kHz, samples averaged to 50 Hz equivalent sampling. Front-end channels have 10 Hz LP filters before the ADCs. Collimator BPM electronics: Diode Orbit System

DOR prototype: lab measurements Now channels 2, 3, 4 are correlated with channel 1, resulting in the coefficients (offset, gain), in the ADC full scale (FS) units: ch2: -0.001720, 1.002262 ch3: 0.000325, 0.998747 ch4: -0.001247, 1.000359 Channel difference improved from 103 to 105 level, by some 2 orders of magnitude. Position error improved also by some 2 orders of magnitude. For amplitudes larger than 20 % of the full scale the noise is not larger than some 50 nm peak-peak, i.e. some 10 nm rms. This is with the 25 dB gain of the high-frequency input amplifiers, 50 Hz ADC equivalent sampling and 10 Hz analogue bandwidth for the orbit changes. The final diode front-end will be equipped with a calibration circuitry capable of connecting the same signal of programmable amplitude to all inputs. The input circuitry will allow the same with beam signals, i.e. the same beam signal can be connected to both front-end channels processing one pick-up plane. Collimator BPM electronics: Diode Orbit System

DOR prototype: lab measurements Input signal made different with fixed attenuators, simulating an offset beam + beam intensity changing. Simulated beam offset is the same for both pick-up planes (both planes connected in parallel). Input signals, gain and sampling as before for the simulated centred beam. Errors some 2 orders of magnitude larger than for the centred beam. Correlating channels does not help significantly. Position measurement dependency on signal intensity for large beam offsets will be addressed in the future development. Collimator BPM electronics: Diode Orbit System

DOR prototype: lab measurements with a calibration mux Measurement with 4 equal signals and calibration mux (not switching), results scaled to 49 mm aperture (i.e. equivalent to 29 mm gap of the collimator BPM). Correlation coefficients used to calibrate the channels, the same coefficients for the whole measurement. Collimator BPM electronics: Diode Orbit System

DOR on collimator BPM: Measurements with the SPS beam RU LD LU RD Drawing from A.Nosych Main role of the embedded BPM system is to indicate when the beam is in the middle between the jaws, i.e. when the signals from the opposing electrodes are equal. Geometrical factor, a constant for “static” BPMs, changes with the jaw distance, fortunately not dramatically, up to some 30 %. Signal amplitude changes with the jaw distance by a factor of 3. Very interesting case from academic point of view (lab-type measurement possible with real beam, online calibration by BPM precise movement). Measurements with one LHC nominal bunch right upstream button left upstream button right downstream button left downstream button Collimator BPM electronics: Diode Orbit System

DOR on collimator BPM: beam tests on the SPS Collimator BPM electronics: Diode Orbit System

LHC: standard vs. DOR processing comparison BPM electrode signals are split and send to both systems Beam position calculation using the same polynomial Aperture 61 mm Collimator BPM electronics: Diode Orbit System

LHC: standard vs. DOR processing comparison Collimator BPM electronics: Diode Orbit System

LHC: standard vs. DOR processing comparison Collimator BPM electronics: Diode Orbit System

BPM Signal Processing with Diode Detectors Conclusions A new technique was developed to process collimator BPM signals with very high resolution. It is optimised for: position resolution; absolute accuracy of beam centring; robustness and simplicity. It assumes: bunch-by-bunch is not needed; required bandwidth is in the Hz range; Larger beam offsets (> 1 mm) do not have to be measured with high precision (< 1 µm). Demonstrated sub-micrometre resolution with single SPS bunches and large collimator gaps. Potentially interesting for precise orbit measurements in critical LHC locations. Things to work on: linearity of the compensated diode detectors; system integration. BPM Signal Processing with Diode Detectors

Collimator BPM electronics: Diode Orbit System Spare slides Collimator BPM electronics: Diode Orbit System

Simple diode detectors for BPM signals One diode detector for each BPM electrode. Subtracting signals before the detectors (e.g. by a 180° hybrid) is no good, as the resulting signals would be: smaller (→ larger nonlinearities); changing signs when crossing the BPM centre. The diode forward voltage Vd introduces a significant position error. Vd depends on the diode current and temperature. Simple diode detectors are good for applications when the signal amplitude is not that important. Two examples: Tune measurement systems An LHC safety system: Beam Presence Flag BPM Signal Processing with Diode Detectors

DOR prototype: lab measurements with a calibration mux Collimator BPM electronics: Diode Orbit System

DOR prototype: lab measurements with a calibration mux corr. for 1 s every 1 h correlation for 60 s corr. for the whole meas. as above, projected to a 49 mm aperture whole Collimator BPM electronics: Diode Orbit System